Casio PRG-60TJ Скачать руководство пользователя страница 14

— 12 —

3-3. CHECKING TERMINALS AND COMPONENTS

Top view of P.C.B. ass'y

Bottom view of P.C.B. ass'y

Capacitor/Chip

Capacitor/Chip

Capacitor/Chip

Capacitor/Chip

Capacitor/Chip

Capacitor/Chip

Capacitor/Chip

Capacitor/Chip

Capacitor/Chip

Capacitor/Chip

Capacitor/Chip

Capacitor/Chip

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10

C11

C12

Capacitor/Chip

Capacitor/Chip

Capacitor/Chip

Capacitor/Chip

Capacitor/Chip

4. Capacitor/Trimmer
 (1001 

0950)

Diode

Diode

Diode

Inverter

Coil

C13

C14

C15

C16

C17

CT

 

Di1

Di2

Di3

INV

LL1

Coil

Thermistor/Chip

Resistor/Chip

Resistor/Chip

Resistor/Chip

Resistor/Chip

Resistor/Chip

Resistor/Chip

Resistor/Chip

Resistor/Chip

Resistor/Chip

Resistor/Chip

LL2

RTH

R1

R4

R5

R6

R7

R8

R9

R10

R11

R12

Resistor/Chip

Resistor/Chip

Resistor/Chip

Transistor

Transistor

13. Oscillator/Crystal
      (7110 6323)

Varistor

7. Cushion/506
    (7211 9631)

8. Cushion/6
    (7211 0064)

16. Sensor/Tilt
      (7105 5275)

R14

R16

R17

Tr1

Tr2

Xtal

Z

KI1

L2

L1

KI9 GND

SD0 SCK CSB

SDI

VSC

GND

KI7

KI3

KI5

KI6

GND

GND

VDD2

VDD2

GND

R1

GND

N2

GND

N1

GND GND

R2

R3

KI4

KI2

VOUT

KI8

KC1 KC2 KC3

IREF1

SN3

ISNS

KI3

KI2

KI6

L-

L+

VSC

VDD2

CLF1

CLF2

VCC

CSB

VDD2

VCC

GND

SDO

LD1

VCC

WP

GND

KI4

AC

VC1

SN4

VCH

OSC4

OSC6

VADY

VADX

GND

VAN

VAN

SN6

SN5

VTH

GND

IREF1

CR

GND

CF

SY

VM2

VADX

VREF2

SN7

GND

SN7

SY

SX

GND

IREF2

SX

SN7

VAN

VADX

VREF1

SN6

SN5

VSC

GND

SCIN

GND

GND

SCIN

GNDB

GND

VDD2

VCC

WP

VSC

SCK

SCR

SCIN

VC2

VC1

VC4

VC3

GND

VCH

GND

VDD3

VDD1

GND

GND

VDSP

VHF

GND

L

GND

VDD2

VDD2

BDB

BD

BDB

BDB

L

L

GND

VDD2

GND

GND

XT

XTB

XT

VDSP

KI5

KI6

L+

VDD2

CLF2

GND

L-

LD1

CLF1

VOUT

VOUT

GND

GND

GND

GND

VCC

WP

SCK

SDO

OSC3

GND

VDD2

KI9

KI5

KI1

L2

L1

L

GND

GND

VM1

L2

L1

SX

SY

VAN

VAN

OSC1

C15

C14

C13

R15

R12

R10

Di3

Di1

Di2

Xtal

INV

C11

C10

LL2

LL1

R17

EEPROM

8

Tr1

R16

C16

R13

R11

R14

C17

RTH

R6

R7

R5

C8

C2

R4

Z

C3

C7

C4

CT

R1

C6

C12 C9

R8

C1

R9

R3

C5

An.B1

7

7

Tr2

16

Содержание PRG-60TJ

Страница 1: ...SERVICE MANUAL PARTS LIST WITHOUT PRICE QW 2766 MODULE NO R REF NO S M 841 FEB 2004 PRG 60TJ...

Страница 2: ...766 3 1 LCD DIAGRAM 10 3 2 CIRCUIT DIAGRAM 11 3 3 CHECKING TERMINALS AND COMPONENTS 12 4 EXPLODED VIEW MODULE QW 2766 13 5 PARTS LIST MODULE QW 2766 15 6 PRECAUTIONS FOR REPAIR MODULE QW 2766 6 1 AC A...

Страница 3: ...10 000 m without reference altitude Measuring unit 5 m Memory capacity One set of memory measurement data which includes up to 41 measurement records date time altitude and one record for maximum alt...

Страница 4: ...the information you need to perform operations in each mode Further details and technical information can be found in the Reference section Most of the display examples in this manual show only the di...

Страница 5: ...Press B to toggle between screens History Graph and Barometric Pressure History graph Temperature Barometric pressure Temperature and Barometric Pressure It can take up to four or five seconds for th...

Страница 6: ...Mode the indicator flashes on the display and measurements are taken every five seconds After that the indicator stops flashing and remains on the display as measurements are taken every two minutes...

Страница 7: ...ement All of the operations in this section are performed in the Stopwatch Mode which you enter by pressing D Hours Minutes Seconds 1 100 second To measure times with the stopwatch First runner finish...

Страница 8: ...mperature Battery This watch is equipped with a solar cell and a rechargeable battery secondary battery that is charged by the electrical power produced by the solar cell The illustration shown nearby...

Страница 9: ...ght Through a Window on a Cloudy Day 5000 lux Indoor Fluorescent Lighting 500 lux The last measured data may still remain on the display if you enter one of the sensor modes while RECOV is on the disp...

Страница 10: ...you again If this does not work drop your arm all the way down so it hangs at your side and then bring it back up again Under certain conditions the backlight may not light until about one second aft...

Страница 11: ...the lower part of the display will show OFF or a barometric pressure value if set l l l l l l l l l l l l l l l l Calibrating the Temperature Sensor The temperature sensor of this watch is calibrated...

Страница 12: ...7 e6 g6 m17 m20 b0 g0 b1 g1 b2 f2 b3 f3 recover b4 f4 b5 f5 b12 hyp1 m37 m40 m47 m50 m57 e11 g11 j11 b11 e10 c10 col0 e9 c9 sleep low charge a11 f11 g11 e11 d11 k11 j11 save autolight sleep recover al...

Страница 13: ...C5 C2 C4 C7 C6 BAT C8 LL1 Tr1 PZ Di1 SC C9 Z Di2 R1 L CLF1 E L VOUT L GND CLF2 V C11 EL LL2 BACK FRONT R3 GNDB ELD Xtal CT S2 SA S1 S3 SK S5 S4 XTB LD1 XT T1 T2 T3 KI1 KI2 KI3 KI4 KI5 KI6 KI7 KI9 AC T...

Страница 14: ...shion 506 7211 9631 8 Cushion 6 7211 0064 16 Sensor Tilt 7105 5275 R14 R16 R17 Tr1 Tr2 Xtal Z KI1 L2 L1 KI9 GND SD0 SCK CSB SDI VSC GND KI7 KI3 KI5 KI6 GND GND VDD2 VDD2 GND R1 GND N2 GND N1 GND GND R...

Страница 15: ...1011 8094 23 1011 8085 18 1011 8083 20 1011 8097 19 1011 8096 9 1011 7191 24 7211 9045 17 1013 4221 20 1011 8097 10 1011 8086 11 1011 8095 14 7227 0252 12 1006 5664 21 7201 9599 1006 5657 Battery Str...

Страница 16: ...14 EXPLODED VIEW ANALOG BLOCK MODULE QW 2766 5 1011 4986 25 7227 0273 25 7227 0273 15 1007 4152...

Страница 17: ...ION 506 Q49364 1 QW 2767YCSA 01 2 C 8 7211 0064 CUSHION 6 Q4914A 1 QW 2767YCSA 01 1 C 9 1011 7191 HOLDER BATTERY Q255819B 2 QW 2767YCSA 01 1 C 10 1011 8086 HOLDER HOUR WHEEL Q373353 1 QW 2767YCSA 01 1...

Страница 18: ...e main plate with the metallic tweezers The contact should be made for about two seconds For 2 seconds after the AC operation do not make any button operations on these modules Metallic tweezers 2 Rem...

Страница 19: ...MODE Press any button except for E NOTE The ACCURACY CHECKING MODE will automatically return to the regular mode in 1 2 hour s without any operation 3 Removing of the sensor A Remove the 2 screws and...

Страница 20: ...and place the watch in a light place in a normal environment for five seconds 2 Check the display indicates as figure 3 3 Turn the display side down and place the watch on the desk for five seconds 4...

Страница 21: ...CASIO TECHNO CO LTD Overseas Service Division 6 2 Hon machi 1 Chome Shibuya ku Tokyo 151 8543 Japan...

Отзывы: