DIAGNOSTIC PROGRAM
44
Launching the Diagnostic Program
4444
[Notes]
If a receipt has been issued in other modes, the Diagnostic Program will not launch.
When this happens, exit and restart the Diagnostic Program. To exit the Diagnostic Program, see "3-2.
Exiting the Diagnostic Program".
Turn the Mode Switch to [PGM].
1.
Press
2.
9
9
9
9
0
0
0
0
SUBTOTAL
.
The Diagnostic Program starts.
3.
The version information of the Diagnostic Program is automatically printed.
4.
Diag Ver: 0427 CSDIAG
Apr 27 2009 13:40
Once the program starts, the status is displayed.
5.
While the Diagnostic Program is running and a test is not being performed, the status is always
indicated. For more about the status, see "[1] Status Display".
Exiting the Diagnostic Program
4444
Turn the Mode Switch to [OFF].
1.
Unplug the Power Cord.
2.
Remove the Backup Memory Battery, and leave it as it is for approximately 1 minute.
3.
Caution
4444
● To forcibly terminate a test, press [C (Clear)] or turn the Mode Switch to [OFF].
If a test is terminated, the device prints out the following:
For the number of test to perform, you may select "once" or "infinite loop".
ESC
● If "0" is entered as the number of times to perform the test, the test will be performed only once.
If any value between "1" and "9" is entered, the test is repeated infinitely. To forcibly terminate the
infinite loop, press [C (Clear)] or turn the Mode Switch to [OFF].
● If a test result fails, the test is terminated regardless of the number of times previously set to perform.
● If the Mode Switch is turned to [OFF] while the Diagnostic Program is running, the light on the
7-Segment turns off. Any command entered during this time is not accepted.
● The winder motor rotates during printing. (No R/J switching function available.)
● If a command of 8 digits or more is entered, the values entered initially are canceled.
2
5
5
2
5
5
1
1
3
0
SUBTOTAL
.
If the above command is entered, the values indicated with double-lined boxes will be displayed in the
7-Segment.
The first two digits, "2" and "5", will be canceled and, therefore, will not be displayed.
● When a command starts with "0", "0" will not be printed.
● When printed characters are hidden behind the printer cover, press [FEED] to advance the printer
paper.
Содержание PCR-T280
Страница 35: ... 33 PCB LAYOUT 777 E276 1 PCB E276 PR PCB ...
Страница 36: ... 34 E276 E2 PCB Main display E276 E22 PCB Rear display ...
Страница 38: ... 36 Model Name Board No Drawing No RJE503230D303 MIAN BOARD EX 276 E276 1 CASIO COMPUTER CO LTD ...
Страница 39: ... 37 Model Name Board No Drawing No RJE503230D305 MIAN DISPLAY BOARD EX 276 E276 E2 CASIO COMPUTER CO LTD ...
Страница 40: ... 38 Model Name Board No Drawing No RJE503230D306 REAR DISPLAY BOARD EX 276 E276 E22 CASIO COMPUTER CO LTD ...
Страница 41: ... 39 Model Name Board No Drawing No CASIO COMPUTER CO LTD RJE503230D404 PRINTER I F BOARD EX 276 E276 PR ...
Страница 44: ... 42 44 42 41 45 43 40 41 44 43 42 41 40 35 S4 36 37 38 34 39 45 ...
Страница 51: ...CASIO COMPUTER CO LTD Overseas Service Division 6 2 Hon machi 1 Chome Shibuya ku Tokyo 151 8543 Japan ...