— 5 —
MEASUREMENT
Measure each value according to the following table and figure, if necessary.
Table-1
Figure-7
Measurement point
Voltage / Current
Condition
VDD1
Min.
4.72V
IDD1 = 30 mA
Max.
5.4V
VDD2
Min.
4.72v
IDD2 = 30 mA
Max.
5.4v
VP
Min.
11.70V
IP = 300 mA
Max.
12.24V
Ibat
Typ.
25 mA
Turning power SW on.
(Displaying)
Max.
100 mA
Ibat
Typ.
0.6A
When printing "CASIO COM..." at diagnostic program
PRINT CHECK-1.
(Printing)
Max
0.7A
When printing " ! " at diagnostic program PRINT CHECK-1.
Ibu
Min.
----
Turning power SW off and disconnecting power
(Power off)
Max.
15
µ
A
source Vbat. Then 3V from CR2032.
Note : Ibat = Power source (Batteries or AC adaptor)
Ibu = Back-up battery (CR2032)
Vbat = 12V
±
2%)
Vbat
GND
Ibat
A
V
PCB L271-1
A
A
A
V
V
V
VDD1
(DP8)
VDD2
DP6
VP
DP5
DP1
DP2
IDD1
IDD2
IP
A
Ibu
DP7
CR2032