Casio G-SHOCK GW-1501B Скачать руководство пользователя страница 7

— 5 —

ATH

CAI

JRS
JED

THR
DXB

KBL

KHI

DEL

DAC

RGN

BKK

HKG

SEL
TYO
ADL

SYD

NOU
WLG

To turn Power Saving on and off

1. In the Timekeeping Mode, hold down 

A

 until the city

code starts to flash, which indicates the setting screen.

2. Press 

C

 nine times until the Power Saving on/off

screen appears.

3. Press 

D

 to toggle Power Saving on (

) and off

(

).

4. Press 

A

 to exit the setting screen.

 The Power Saving on indicator is on the display in all

modes while Power Saving is turned on.

Auto Return Features

 The watch automatically returns to the Timekeeping Mode if you do not perform any

button operation for two or three minutes while the Battery Level Screen is
displayed, or while in the Alarm, or Hand Setting Mode.

 If you leave a screen with flashing digits on the display for two or three minutes

without performing any operation, the watch automatically exits the setting screen.

l l l l l l lll

lll

ll

ll

l

Power saving
on indicator

Scrolling

The 

B

 and 

D

 buttons are used in various modes and setting screens to scroll

through data on the display. In most cases, holding down these buttons during a scroll
operation scrolls through the data at high speed.

Initial Screens

When you enter the Timekeeping, World Time, or Alarm Mode, the data you were
viewing when you last exited the mode appears first.

Timekeeping

 Resetting the seconds to 

00

 while the current count is in the range of 30 to 59

causes the minutes to be increased by 1. In the range of 00 to 29, the seconds are
reset to 

00

 without changing the minutes.

 The year can be set in the range of 2000 to 2099. The day of the week is calculated

automatically in accordance with the date.

 The watch’s built-in full automatic calendar makes allowances for different month

lengths and leap years. Once you set the date, there should be no reason to change
it except after you have the watch’s battery replaced or when battery power drops to
Level 4.

 The current time for all city codes in the Timekeeping Mode and World Time Mode is

calculated in accordance with the Greenwich Mean Time (GMT) differential for each
city, based on your Home City time setting.

 GMT differential is calculated by this watch based on Universal Time Coordinated

(UTC

*

) data.

*

 

UTC is the world-wide scientific standard of timekeeping. It is based upon carefully

maintained atomic (cesium) clocks that keep time accurately to within microseconds.
Leap seconds are added or subtracted as necessary to keep UTC in sync with the
Earth’s rotation. The reference point for UTC is Greenwich, England.

12-hour/24-hour Timekeeping  Formats
The 12-hour/24-hour timekeeping format you select in the Timekeeping Mode is
also applied in all other modes.

 With the 12-hour format, the P (PM) indicator appears on the display for times in the

range of noon to 11:59 p.m. and no indicator appears for times in the range of
midnight to 11:59 a.m.

 With the 24-hour format, times are displayed in the range of 0:00 to 23:59, without

any indicator.

Illumination Precautions

 The illumination provided by the light may be hard to see when viewed under direct

sunlight.

 Illumination automatically turns off whenever an alarm sounds.

 Frequent use of illumination shortens the battery operating time.

Auto light switch precautions

 Wearing the watch on the inside of your wrist, movement of your arm, or vibration of

your arm can cause frequent activation of the auto light switch and illumination of the
face of the watch. To avoid running down the battery, turn off the auto light switch
whenever engaging in activities that might cause frequent illumination of the face.

 Note that wearing the watch under your sleeve while the auto light switch is turned

on can cause frequent illumination of the face and can run down the battery.

 Illumination may not turn on if the face of the watch is

more than 15 degrees above or below parallel. Make
sure that the back of your hand is parallel to the ground.

 Illumination turns off after the preset illumination

duration (see “To specify the illumination duration”), even
if you keep the watch pointed towards your face.

 Static electricity or magnetic force can interfere with

proper operation of the auto light switch. If illumination
does not turn on, try moving the watch back to the
starting position (parallel with the ground) and then tilt it
back towards your face again. If this does not work, drop
your arm all the way down so it hangs at your side, and
then bring it back up again.

 Under certain conditions, illumination may not turn on

until about one second after you turn the face of the
watch towards you. This does not necessarily indicate
malfunction of the auto light switch.

 You may notice a very faint clicking sound coming from

the watch when it is shaken back and forth. This sound
is caused by mechanical operation of the auto light
switch, and does not indicate a problem with the watch.

More than 15 degrees
too high

Honolulu

Anchorage

Los Angeles

Denver

Chicago

New York

Caracas

Rio De Janeiro

London

Paris

Berlin

City

City

GMT

Other major cities in same time zone

Code

Differential

City Code Table

–11

HNL
ANC

LAX

DEN

CHI

NYC

CCS

RIO
–02
–01

GMT

LON

PAR

BER

–11.0
–10.0
–09.0

–08.0

–07.0

–06.0

–05.0

–04.0
–03.0
–02.0
–01.0

+00.0

+01.0

Pago Pago
Papeete
Nome
San Francisco, Las Vegas, Vancouver,
Seattle/Tacoma, Dawson City
El Paso, Edmonton
Houston, Dallas/Fort Worth,
New Orleans, Mexico City, Winnipeg
Montreal, Detroit, Miami, Boston,
Panama City, Havana, Lima, Bogota
La Paz, Santiago, Port Of Spain
Sao Paulo, Buenos Aires, Brasilia, Montevideo

Praia
Dublin, Lisbon, Casablanca, Dakar, Abidjan

Milan, Rome, Madrid, Amsterdam, Algiers, Hamburg,
Frankfurt, Vienna, Stockholm

Athens

Cairo

Jerusalem

Jeddah

Tehran

Dubai
Kabul

Karachi

Delhi

Dhaka

Yangon

Bangkok

Hong Kong

Seoul
Tokyo

Adelaide

Sydney

Noumea

Wellington

+02.0

+03.0
+03.5
+04.0
+04.5
+05.0
+05.5
+06.0
+06.5
+07.0

+08.0

+09.0

+09.5
+10.0
+11.0
+12.0

Helsinki, Istanbul, Beirut, Damascus,
Cape Town

Kuwait, Riyadh, Aden, Addis Ababa, Nairobi, Moscow
Shiraz
Abu Dhabi, Muscat

Male
Mumbai, Kolkata
Colombo

Jakarta, Phnom Penh, Hanoi, Vientiane
Singapore, Kuala Lumpur, Beijing, Taipei, Manila, Perth,
Ulaanbaatar
Pyongyang

Darwin
Melbourne, Guam, Rabaul
Port Vila
Christchurch, Nadi, Nauru Island

Based on data as of June 2004.

Содержание G-SHOCK GW-1501B

Страница 1: ...SERVICE MANUAL PARTS LIST WITHOUT PRICE QW 3765 MODULE NO R REF NO S M 880 FEB 2005 GW 1501B GW 1501S Ver 1 May 2006...

Страница 2: ...AGRAM 6 3 2 CIRCUIT DIAGRAM 7 3 3 CHECKING TERMINALS AND COMPONENTS 8 4 EXPLODED VIEW MODULE QW 3765 9 5 PARTS LIST MODULE QW 3765 10 6 PRECAUTIONS FOR REPAIR MODULE QW 3765 6 1 AC ALL CLEAR AND REMOV...

Страница 3: ...unctions Shock resistant G SHOCK Super Illuminator Full auto LED light Solar powered World time 29 time zones 30 cities city code display daylight saving on off 1 100 second stopwatch Measuring capaci...

Страница 4: ...set with a number of city codes each of which represents the time zone where that city is located When setting the digital time it is important that you select the correct city code for your Home City...

Страница 5: ...ress C to move the flashing between the hour and minute settings 4 While a setting is flashing use D and B to change it When setting the alarm time using the 12 hour format take care to set the time c...

Страница 6: ...time and digital time do not match after the watch recovers to Level 2 from Level 3 or Level 4 adjust the analog hand setting so it matches the digital time Leaving the watch exposed to direct sunligh...

Страница 7: ...provided by the light may be hard to see when viewed under direct sunlight Illumination automatically turns off whenever an alarm sounds Frequent use of illumination shortens the battery operating ti...

Страница 8: ...Y4 X11Y3 X11Y2 X11Y1 X11Y0 X12Y4 X12Y3 X12Y2 X12Y1 X12Y0 X13Y4 X13Y3 X13Y2 X13Y1 X13Y0 X14Y4 X14Y3 X14Y2 X14Y1 X14Y0 X15Y4 X15Y3 X15Y2 X15Y1 X15Y0 X16Y4 X16Y3 X16Y2 X16Y1 X16Y0 RECOVER A LIGHT X4Y4 X4...

Страница 9: ...13 12 13 11 1 1 1 1 1 3 3 2 2 2 1 No bonding 2 GND Kl5 Open No Soldering GND Kl6 Short Soldering GND Kl7 Short Soldering 3 Latch type key 4 Short Soldering R trimming 5 Short Soldering N trimming 6 G...

Страница 10: ...OUT GND GND LD1 CE1 CE2 VSC L 9 L 8 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20 L21 L22 L23 L24 L25 L26 L27 L28 L29 L30 LED2 VOUT LED1 VDD2 VOUT COIL P4 P5 P7 GND SCIN GND GND X3 X2 P5 CE2 CE1 GND VOU...

Страница 11: ...9 2 1006 5657 Battery storage CTL1616 14 1015 7977 Casing parts SOLAR CELL 9 1015 5782 Casing parts DIAL SPACER 5 1001 6598 16 7640 8453 PCB Ass y 8 1001 4042 20 7201 9249 12 1015 5784 8 1001 4042 13...

Страница 12: ...1001 4042 CUSHION 2306 1 Q466421 1 QW 3765AT 01TK 2 C 9 1015 5782 HOLDER 3329 RJQ518016 001V02 QW 3765AT 01TK 1 C 10 1001 6591 HOLDER BATTERY Q366808 1 QW 3765AT 01TK 1 C 11 1015 5789 HOLDER HOUR WHEE...

Страница 13: ...KING Check the accuracy of the module with the quartz timer after switching the module to ACCURACY CHECKING MODE The operations are shown below A SWITCHING TO ACCURACY CHECKING MODE While pressing the...

Страница 14: ...the watch more than two seconds 4 Check the display indicates as figure 3 If is not appeared on the display disassemble again the module and check the contact spring between the Solar cell and PCB 3 T...

Страница 15: ...Ver 1 May 2006 Correction of pages 9 and 10 CASIO COMPUTER CO LTD Overseas Service Division 6 2 Hon machi 1 Chome Shibuya ku Tokyo 151 8543 Japan...

Отзывы: