SAFETY MEASURES
The power will be turned off automatically when FV-600 is in the following conditions.
1. Fan is stopped.
2. High temperature
(1) Thermistor detects high temperature.
(2) Bimetal detects high temperature.
3. Fan filter is not set properly.
4. Rear cover is not set properly.
ALARM DESCRIPTION
Power LED
Alarm LED
Beep
Description
Green On
Off
-
Power on
OK
Off
Off
-
Power off
Red On
Off
-
Power off by remote control
Green Blink
Off
-
Cooling off (Fan is working.)
Green On
Red Blink
Twice
High temperature warning
(Check the fan and fan filter.)
NG
Red Blink
Red Blink
Three times
1. Lamp is defective.
2. Fan is defective.
Red On
Red Blink
Once
1. Fan filter warning
(Check if the fun filter is set.)
2. Rear cover warning
(Check if the rear cover is set.)
Содержание FV-600P