– 2 –
EX-ZR300
3. Camera Settings
Set the Sleep mode to "OFF", and then launch the TEST MODE.
(Avoid LCD being turned off during the adjustment as the result of the Sleep mode activation.)
<Procedure>
(1) Turn the camera on while holding down the [MOVIE] and the [UP].
(2) Press the [DOWN] twice, press the [UP] and then press the [MENU].
(3) Select and run "2: USB TCC TEST".
(4) Select "1: USB TCC ON", press the [RIGHT] twice and then press the [SET].
(Ensure that the camera starts up in the TEST MODE when switched on.)
(5) Select and run "8: ADJ TEST". The display shown below appears.
(6) Select and run the desired adjustments. (See the figure below.)
1: ADJ STAT CLR
2: LCD
3: LENS
4: PICTURE
5: POWER
6: IS
WB1 adjustment
WB2 adjustment
SHUTTER adjustment
SHADING adjustment
CCD DEFECT adjustment
ISO adjustment
FOCUS adjustment
MACRO adjustment
ZOOM adjustment
OPT CENTER adjustment
(7) After adjustment ends, select and run "2: USB TCC TEST".
(8) Select and run "2: USB TCC OFF". (This clears the mode selected in step 4 above.)
(9) Select and run "4: LAST MEMORY".
(10) When "PUSH OK KEY" appears, press the [SET]. (The factory default settings are restored.)