![Casio EX-I/O-PB-12 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/casio/ex-i-o-pb-12/ex-i-o-pb-12_service-manual_2569778004.webp)
— 2 —
1-2. I/O PB-12 board cables connection
C N2
Inline
Connector
C N3
Kitchen
Printer
Connector
SW1
IRQ No. selection
SW2
IRQ No. selection
SW3
I/O Port address
selection
Red wire
C N4
From Power sup p ly (UPS)
1)
Connect the following cable to the I/O-PB12.
CN2: Kitchen printer
CN3: In-line
CN4: Power cable from the UPS.
Ensure that the red dot line mark is No.1 pin.
2)
The standard setting for SW1(INT1), SW2(INT2) and SW3(PORT) are as follows:
SW1: Standard setting is IRQ10.
SW2: Standard setting is IRQ11.
SW3: Standard setting is 1E0H.