— 12 —
0 0 - 0 0 - 0 0
0 0 - 0 0 # 0 0 0 2
- d1d2d3d4 - - d5d6d7
Print ing Layout
0 0 - 0 0 - 0 0
0 0 - 0 0 # 0 0 0 2
- 2 8 6 2 - - 1 - -
Receipt sample
d1d2d3d4 :
Version No.
d5 :
PAD condition
0
:
Japan
1 :
Export (ADD2)
2 :
US / Canada
3 :
Export (ADD3)
4 :
Export (ADD1)
d6 :
0 :
Non taxable (Japan)
1 :
Taxable (Japan)
- :
Export version
d7:
0 :
118ER (Japan)
1 :
108ER (Japan)
- :
Export version
6 DIAGNOSTIC OPERATIONS
6-1. To start the diagnostic operation
1. Make MAC operation.
2. Turn the mode switch to PGM position.
3. Input "99999999" and press "SUB TOTAL" key.
Note : Do not issue the receipt under REG / RF / X / Z mode before execute the diagnostic.
If the machine issued a receipt, the diagnostic does not start.
6-2. Check items
The following test can be checked in the test mode.
1. Key code check
2. Switch check
3. Individual function check