E-33
1
RS-232C Interface
For connection of a PC and uploading/downloading of system data
and file data.
2
RS-485 Interface
For connection of multiple optional Basic Cradles.
3
AC adaptor jack
For connection of an AC adaptor to supply power.
4
Nose Guide
Remove this guide when you are using the down-facing reader
port model.
5
Data Collector detection switch
Detects whether or not the Data Collector is mounted correctly on
the Basic Cradle.
6
Data communication indicator
Indicates the status of data communication operations.
Off:
Not communicating
Flashing Green:
Communication in progress
7
Power indicator
Indicate whether power is ON or OFF, and if the Data Collector is
mounted.
Off:
Power OFF
Lit Red:
Power ON, Data Collector not mounted
Lit Green: Power ON, Data Collector mounted
8
Installation covers (L, R)
Hold down the charge/power supply terminals when the Basic
Cradle is used as an installed type.
9
Charge/Power supply terminal
Supplies power to the Data Collector mounted on the Basic
Cradle.
10 Infrared port
This port provides contact-less infrared communication capability
with the Data Collector.
11 Power switch
Turns power ON and OFF.
12 Base
Reverse the position of the base when wall-mounting the Basic
Cradle.
13 DIP switches
Use these switches to set the operational configuration of the
Basic Cradle.
14 Wall mounting hole