
— 35 —
11-3 Sensor/Pressure Quality Evaluation
Tool used
Evaluation of the quality of the sensor/pressure is performed by
measuring the resistance values detected from the four terminals
on the sensor. The resistance values between each terminal are
as shown right. (Fig. 11-2)
If any one of the measured values is found to be outside the
standard value, the sensor or module with sensor have to be re-
placed.
11-4 Removal and Attachment of Sensor/Pressure
In case the module with sensor is removed from the case for the replacement of sensor/pressure,
module with sensor or case/center ass’y and so forth, the module and the sensor/pressure should be
separated and they should be removed one by one.
The procedure of removal and attachment of sensor/pressure is as shown below.
11-4-1 Sensor/Pressure Equipped on Side of the Watch
For the names of each parts and construction, please refer to page 19 the exploded view of the
Watches Equipped with a Sensor/Pressure (Side Sensor).
1) Open the cover/back.
2) Remove the screw holding the flexible cable over the module along with the holder, and separate
the flexible cable from the module.
3) Remove all parts including the cap/sensor, cover/sensor and packing/o-ring (sensor)
4) While holding onto the flexible cable with a tweezers, remove the sensor/pressure by pushing it to
the outside from the sensor box of the case/center.
5) Install a new sensor/pressure by first inserting the cable into the case.
Be careful so that the sensor is positioned correctly.
In addition, do not break the cable by pinching with the tweezers or bending excessively.
6) Install the cable in the module, attach the holder, tighten the screw and connect the module and
sensor.
7) Perform the AC (All Clear) procedure when the module and sensor have been connected.
Air pressure will not be measured and "SENSOR ERROR" will continue to be displayed if this AC
procedure is not performed.
8) Perform sensor trimming with the Sensor/pressure trimming jig set in case only the sensor/pres-
sure is replaced with new one.
9) In the case of water-resistant watches, always make sure to perform the waterproof inspection
after the repair is completed.
NO.
Code No.
Tool name
1
1901 9708 Aneroid barometer (3-1050-05)
2
1901 9672 Precision screwdriver set
3
1901 9523 Precision tweezers
4
1904 5277 Multimeter
5
1901 9924 Pressure sensor trimming jig set
6
1901 9949 Holder (for ALT-6000)
7
Holder (Universal)
8
1901 9519 Blower brush
Sensor
F. P. C.
Joiner
A B
C D
A
←
3.75
±
0.75 K
Ω
→
B
C
←
3.75
±
0.75 K
Ω
→
D