Casio 5477 Скачать руководство пользователя страница 17

L-3

City

Code

City

UTC Offset/

GMT Differential

DEL

Delhi

+5.5

KTM

Kathmandu

+5.75

DAC

Dhaka

+6

RGN

Yangon

+6.5

BKK

Bangkok

+7

SIN

Singapore

+8

HKG

Hong Kong

BJS

Beijing

TPE

Taipei

SEL

Seoul

+9

TYO

Tokyo

ADL

Adelaide

+9.5

GUM

Guam

+10

SYD

Sydney

NOU

Noumea

+11

WLG

Wellington

+12

 This table shows the city codes of this watch. 

(As of January 2016)

 The rules governing global times (GMT 

differential and UTC offset) and summer time 
are determined by each individual country.

L-2

City Code Table

City

Code

City

UTC Offset/

GMT Differential

PPG

Pago Pago

–11

HNL

Honolulu

–10

ANC

Anchorage

–9

YVR

Vancouver

–8

LAX

Los Angeles

YEA

Edmonton

–7

DEN

Denver

MEX

Mexico City

–6

CHI

Chicago

NYC

New York

–5

YHZ

Halifax

–4

YYT

St. Johns

–3.5

BUE

Buenos Aires

–3

RIO

Rio De Janeiro

FEN

Fernando de 

Noronha

–2

RAI

Praia

–1

City

Code

City

UTC Offset/

GMT Differential

UTC

0

LIS

Lisbon

LON

London

MAD

Madrid

+1

PAR

Paris

ROM

Rome

BER

Berlin

STO

Stockholm

ATH

Athens

+2

CAI

Cairo

JRS

Jerusalem

MOW

Moscow

+3

JED

Jeddah

THR

Tehran

+3.5

DXB

Dubai

+4

KBL

Kabul

+4.5

KHI

Karachi

+5

L-1

E-129

 Power Supply:

 Solar panel and one rechargeable battery

Approximate battery operating time: 6 months (from full charge to Level 4) under the following 

conditions:

 Alarm: 10 seconds/day

 Light: 1.5 seconds/day

 Time calibration receive: 4 minutes/day

 Display on 18 hours/day, sleep mode 6 hours/day

 Direction reading: 20 times/month (60 seconds continuous reading)

 Barometric Pressure Graph Measurement: 12 times/month

 Mountain Climbing: 0.5 times/month

(Altitude Measurement: Approximately 1 hour; Barometric Pressure Information Measurement: 

Approximately 24 hours)

 Depth Meter Measurement: 60 minutes continuous, 0.5 times/month

Approximate battery life can be shortened by more frequent light operation.

Specifi cations are subject to change without notice.

E-128

Temperature Sensor Precision:

±2°C (±3.6°F) in range of –10°C to 60°C (14.0°F to 140.0°F)

Water depth sensor accuracy:

–0.5 to +1.0 m (guaranteed accuracy temperature range: –10°C to 60°C)

* Indicated depths are for seawater (Specifi c Gravity: 1.025)

Tide/Moon Data: 

Tide levels (Tide Graph), Moon age; date selection; time selection (Tide Graph only)

Sunrise/sunset:

Sunrise/sunset time display; selectable date

Stopwatch:

Measuring unit: 1/100 second
Measuring capacity: 23:59' 59.99"
Measuring modes: Elapsed time, split time, two fi nishes

Countdown Timer:

Measuring unit: 1 second
Countdown range: 60 minutes
Setting unit: 1 minute

Alarms:

 5 Daily alarms; Hourly time signal

World Time:

 48 cities (31 time zones), UTC (Coordinated Universal Time); Home City/World Time City 

switching; one-touch UTC zone access

Other: Daylight Saving Time/Standard Time

Illumination:

 LED light (LCD, analog hand area); Selectable illumination duration (approximately 1.5 

seconds or 3 seconds); Auto Light Switch (Full Auto Light operates only in the dark)

Other:

 Battery power indicator; Power Saving; Button operation tone on/off; alarm test; auto hand position 

adjustment; hand shift feature (to view digital info)

C

Operation Guide 5477

Содержание 5477

Страница 1: ...eed movement or press any button E 3 Using the Crown The crown of this watch is a screw in lock crown Before using the crown you must rst rotate it towards you to loosen it After performing crown oper...

Страница 2: ...ble or disable Power Saving E 115 Troubleshooting E 116 Speci cations E 125 E 11 Checking the Tide Level and Moon Ages Tide Moon E 96 To view the tide level and Moon age for a speci c date and time E...

Страница 3: ...ation signal transmitters so certain conditions may cause reception problems When HKG or BJS is selected as the Home City only the time and date are adjusted according to the time calibration signal Y...

Страница 4: ...t possible the watch keeps time with the precision noted in Speci cations The receive operation is disabled under any of the conditions below While power is at Level 3 L or lower page E 15 While the w...

Страница 5: ...a m or P p m indicator will also be displayed This is the time setting mode In the following steps each press of B cycles between settings as shown below Home City DST Hour minute Month Day Hour Year...

Страница 6: ...Mode page E 30 This enters the Barometer Mode and displays a barometric pressure reading after about one second After a barometric pressure reading operation is started the watch will take readings e...

Страница 7: ...ressure change indication will turn off automatically 24 hours after you turn it on or if battery power goes low Note that time calibration signal reception and power saving page E 19 are disabled whi...

Страница 8: ...readings If you plan to take direction readings in an open eld for example calibrate in an open eld To perform gure 8 calibration 1 In the Digital Compass Mode pull out the crown 2 Press A Move your a...

Страница 9: ...l 1 In the Altimeter Mode page E 31 pull out the crown This will cause the current altitude reading value to appear 2 Press B This will cause INT to appear on the digital display along with the ashing...

Страница 10: ...e of this the readings produced by this watch will not match the altitude readings announced or indicated by the ight crew E 75 How does the altimeter work Generally air pressure decreases as altitude...

Страница 11: ...pressure increases one atmosphere 1 03kg cm2 with each 10 meter increase in depth The water depth sensor of your watch detects water pressure and the watch uses the relationship between water pressure...

Страница 12: ...least three seconds After CLEAR starts to ash on the display keep C depressed for another two seconds and release it when CLEAR ALL stops ashing and remains displayed and will alternate on the display...

Страница 13: ...n as in step 2 of this procedure to specify a time Calibrating the High Tide Time You obtain more accurate tide indications by the watch by calibrating its high tide time with information you can nd o...

Страница 14: ...e Timekeeping Mode reaches the preset alarm time This is true even if the watch is not in the Timekeeping Mode You can also turn on an Hourly Time Signal which will cause the watch to beep twice every...

Страница 15: ...e reading the watch s second hand points to 9 o clock The reading value is outside of the allowable measurement range See page E 48 There may be a problem with the sensor If ERR error is on the digita...

Страница 16: ...out its down times Try again later The current time setting changes after I set it manually You may have the watch con gured for auto receive of the time calibration signal page E 23 which will cause...

Страница 17: ...continuous reading Barometric Pressure Graph Measurement 12 times month Mountain Climbing 0 5 times month Altitude Measurement Approximately 1 hour Barometric Pressure Information Measurement Approxim...

Отзывы: