Temperature Sensor Precision:

±2°C (±3.6°F) in range of –10°C to 60°C (14.0°F to 140.0°F)

Sunrise/sunset:

Sunrise/sunset time display; selectable date

Stopwatch:

Measuring unit:  1/10 second
Measuring capacity:  999:59' 59.9"
Measuring accuracy:  ±0.0006%
Measuring modes:  Elapsed time, split time, two finishes

Countdown Timer:

Measuring unit:  1 second
Countdown range:  24 hours
Setting unit:  1 minute

Alarms:

  5 Daily alarms (with one snooze alarm); Hourly time signal

World Time:

  48 cities (31 time zones)

Other:  Daylight Saving Time/Standard Time

Illumination:

  LED light; Selectable illumination duration (approximately 1.5 seconds or 3 seconds); 

Auto Light Switch (Full Auto Light operates only in the dark)

Other:

  Battery power indicator; Power Saving; Low-temperature resistance (–10°C/14°F); Button 

operation tone on/off

E-14

Altimeter:

Measurement range:  –700 to 10,000 m (or –2,300 to 32,800 ft.) without reference altitude
Display range:  –10,000 to 10,000 m (or –32,800 to 32,800 ft.)

Negative values can be caused by readings produced based on a reference altitude or due to 
atmospheric conditions.

Display unit:  1 m (or 5 ft.)
Current Altitude Data:  Every second for the first 3 minutes, followed by every 5 seconds for 

approximately 1 hour (

0'05

); every second for the first 3 minutes, followed 

by every 2 minutes for approximately 12 hours (

2'00

)

Altitude Memory Data:

Manually saved records: 30 (altitude, date, time)
Auto saved values:  One set of high altitude and its reading date and time, low altitude and its 

reading date and time, total ascent and its save start date and time, total 
descent and its save start date and time

Trek log data:  High altitude, low altitude, cumulative ascent, cumulative descent for up to 14 

treks

Other:  Reference altitude setting; Altitude differential; Altitude auto measurement interval (

0'05

 or 

2'00

)

Bearing Sensor Precision:

Direction:  Within ±10°

Values are guaranteed for a temperature range of –10°C to 60°C (14°F to 140°F).

North pointer:  Within ±2 digital segments

Pressure Sensor Precision:

Measurement accuracy: Within ±3 hPa (0.1 inHg) (Altimeter accuracy: Within ±75m (246 ft.))

 

x

 Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).

 

x

 Precision is lessened by strong impact to either the watch or the sensor, and by temperature 
extremes.

E-13

Specifications

Accuracy at normal temperature:

  ±15 seconds a month

Timekeeping:

  Hour, minute, second, p.m. (P), year, month, day, day of the week

Time format:  12-hour and 24-hour
Calendar system:  Full Auto-calendar pre-programmed from the year 2000 to 2099
Other:  Three display formats (day of the week/day screen, month/day screen, barometric pressure 

graph screen); Home City code (can be assigned one of 48 city codes); Standard Time / 
Daylight Saving Time (summer time)
Year display on setting screen only.

Digital Compass:

  60 seconds continuous reading; 16 directions; Angle value 0° to 359°; Four 

direction pointers; Calibration (bidirectional); Magnetic declination correction; 
Bearing Memory

Barometer:

Measurement and display range:

260 to 1,100 hPa (or 7.65 to 32.45 inHg)

Display unit:  1 hPa (or 0.05 inHg)
Reading timing:  Daily from midnight, at two-hour intervals (12 times per day); Every five seconds 

in the Barometer/Thermometer Mode

Other:  Calibration; Manual reading (button operation); Barometric pressure graph; Barometric 

pressure differential pointer; Barometric pressure change indicator

Thermometer:

Measurement and display range:  –10.0 to 60.0°C (or 14.0 to 140.0°F)
Display unit:  0.1°C (or 0.2°F)
Reading timing:  Every five seconds in the Barometer/Thermometer Mode
Other:  Calibration; Manual reading (button operation)

E-12

Mode Settings

For full details about timer, alarm, World Time City summer time, and other settings, and about 
calibrating measurements (direction, altitude, barometric pressure, temperature), refer to the 
Operation Guide available at the CASIO website.

E-11

Screen

To do this:

Do this:

Reset the second to 

00

(If the current seconds count is between 30 and 59, 
one is added to the minute count).

Press 

A

.

Change the hour or minute

Use 

A

 (+) and 

C

 (–).

Change the year, month, or day

4.  After all of the settings are the way you want, press 

E

 twice to exit the setting screen.

E-10

Changing the Current Time and Date Settings

1.  In the Timekeeping Mode, hold down 

E

 for at least two seconds. Keep 

E

 depressed until the 

city code and city name starts to scroll.

2.  Press 

D

 to move the flashing in the sequence shown below to select the other settings.

City Code

DST

Year

Thermometer/Barometer/ 
Altitude display unit

12/24-Hour 
Format

Second

Hour

Minute

Month

Day

Button Operation 
Tone

Illumination 
Duration

Power 
Saving

3.  When the timekeeping setting you want to change is flashing, use 

A

 and/or 

C

 to change it as 

described below.

Screen

To do this:

Do this:

Change the city code

Use 

A

 (East) and 

C

 (West).

Toggle between Daylight Saving Time (

ON

) and 

Standard Time (

OFF

).

Press 

A

.

Toggle between 12-hour (

12H

) and 24-hour (

24H

timekeeping.

Press 

A

.

E-9

Data Recall Mode

Stopwatch Mode

Alarm Mode

Timer Mode

Last displayed record

 

x

Scroll

 

x

Scroll

 

x

Select data type

Minutes Seconds

1/10 second

Hours

 

x

Split

 

x

Reset

 

x

Start

 

x

Stop

 

x

Reset

 

x

Start

 

x

Stop

Minutes

Seconds

 

 

x

Scroll

 

x

Scroll

 

x

On/Off

D

D

D

D

E-8

Navigating to Other Modes

Timekeeping Mode

Sunrise/Sunset Mode

World Time Mode

Month, day

 

x

Select screen

Barometric pressure 
graph

Day of the week, day

  

x

Scroll

 

x

Scroll

Sunset time

Sunrise time

Home City time

World Time City 
time

World Time City 
code

 

x

Scroll

 

x

Scroll

D

D

D