Casio 3334 Скачать руководство пользователя страница 2

Operation Guide 3334

2

Positioning Your Arm Correctly

You should be wearing the watch on the outside of your wrist
when using the auto light switch.

Make sure that the left (9 o’clock)
and right (3 o’clock) sides of the
watch are within 

±

15 degrees of

being parallel with the ground.
The auto light switch may not
operate properly if the angle is
greater.

Important!

The light may be difficult to see if you turn it on under bright
sunlight.

If you press the 

L

 button or if an alarm operation starts while the

display is illuminated, illumination will turn off.

Charging Precautions

Avoid charging the watch in the following locations, and anywhere
else the watch may become very hot.

On the dashboard of an automobile parked in the sun

Very close to an incandescent light source or other sources of
heat

In a location exposed to direct sunlight for long periods

Note that the display panel may become black under very high
temperatures. This is temporary, and the display will appear
normal again at lower temperatures.

Depending on the light source you are using, the
case of the watch may become quite hot during
charging. Take care to guard against burn injury
after charging.

Charging the Battery

Point the solar panel (face) of the watch at a light source.

Remember that even a partial blockage of the solar cell reduces
charging efficiency.

Example: Positioning the watch

Solar Cell

The illustration shows the resin band model.

Charging Guide

Starting from a full charge, the watch
should be able to continue operating
for about seven months without
further charging under the conditions
described below.

Daily Use (All time values are
approximate.)

Illumination: 1.5 seconds

Alarms: 10 seconds

Signal reception: 5 times

Digital display: 18 hours

Making sure the watch is regularly
exposed to light ensure stable
operation.

Charge Times Required to Advance to a Higher Level

Charging Time

Level 4  

\

 Level 3  

\

 Level 2  

\

 Level 1 

– – –

– – –

2 hr.

5hr.

19hr.

7 hr.

11 hr.

113hr.

22hr.

97hr.

36hr.

157hr.

Environment 

(Luminosity)

Outdoor sunlight 

(50,000 lux) 

Indoor sunlight 

(10,000 lux) 

Outdoor overcast 

(5,000 lux) 

Fluorescent indoor 

lighting (500 lux)

Note that the above charging times are for reference only. Actual
charging time depends on a variety of environmental factors.

The power supply of this watch uses a solar cell to generate
electrical power, which is stored by a rechargeable battery. Using
or storing the watch where it is not regularly exposed to light, or
allowing it to be blocked from light by your sleeve as you are
wearing it can cause the power of the rechargeable battery to run
down. To ensure stable operation, be sure to allow the watch to be
exposed to light as much as possible when you are wearing or
storing it.

Note that all data in memory and all settings are cleared
whenever you allow the level of the rechargeable battery
to drop to Level 4.

Flashing RECOVER Indicator

If you use the light or alarms a number of times during a short
period, a RECOVER indicator flashes in the top dial, and the
following operations become disabled as battery power recovers.

Illumination

Alarm and Hourly Time Signal

Time calibration signal reception

Normal operation will return after the
battery recovers.

Power Supply

Auto Light Precautions

Frequent use of the auto light can run down the battery.

The auto light switch may cause the display to illuminate when
your sleeve covers the display of the watch.

The display may not illuminate immediately when you angle the
watch towards your face. This does not indicate malfunction.

The display remains lit for the currently set illumination duration
(1.5 or 2.5 seconds) only, even if you leave the watch angled
towards your face.

The auto light switch is automatically disabled whenever battery
power is at Level 3 or lower.

The display may illuminate unintentionally when you wear the
watch on the inside of your wrist, when you shake your arm, or
when you raise your arm. Be sure to turn off the auto light
switch whenever you do not need illumination
.

Keep the auto light switch turned off whenever you are wearing
the watch on the inside of your wrist.

Electro-static charge and magnetism can interfere with auto light
operation and even make operation impossible. If this happens
lower your arm to the starting position and then raise it again. If
you still have trouble with illumination, try lowering your arm down
to your side and then raise it to your face for reading.

Illumination

RECOVER
Indicator

Required Daily Charging Time 

• 

The following is the daily 
amount of charging required 
each day to support the 
operations under “Daily Use”.

Environment 

(Luminosity)

Outdoor sunlight 

(50,000 lux) 

Indoor sunlight 

(10,000 lux) 

Outdoor overcast 

(5,000 lux) 

Fluorescent indoor 

lighting (500 lux)

6min.

30min.

48min.

8hr.

Charging 

Time

Rotate your arm so the watch
is angled at about 40 degrees,
so you can read its face.

With the watch on
your wrist, position it
level with the ground.

1

1

1

1

1

2

2

2

2

2

More
than 40
degrees

Battery Indicator

All functions enabled.

All functions enabled.

Level

1

Level

2

Level

3

Level

4

Display, illumination, alarms, Hourly 
Time Signal, signal reception, and 
analog timekeeping disabled. 

All functions, including digital 
timekeeping, disabled. 

Black-On-

White 

Display

White-On-

Black 

Display

Exposing the watch to direct sunlight or other strong light may cause
the battery level indicator to momentarily indicate a level that is higher
than the actual battery level. Because of this, you should wait for a
short while after charging to check the battery level indicator.

Even if the battery level drops all the way to Level 4, you will still
be able to recharge the battery and use the watch again.

When recharging from Level 4, set the current time and date after
the battery level recharges to Level 3. At this time you should
continue to expose the watch to light so it can charge up to Level
2 or Level 1.

Start charging at Level 3!

Battery Level 3 indicates that remaining battery power is very low.
Be sure to expose the watch to light for recharging as soon as
possible after the battery level indicator shows Level 3.

Illuminating the Display with the
Auto Light Switch

The auto light switch automatically illuminates the display
whenever you angle the watch towards your face for reading,
but only when it is dark.
You can use the procedure under “Specifying the Illumination
Duration” to configure the illumination duration as
approximately 1.5 seconds or 2.5 seconds.

The auto light switch does not illuminate the display when
surrounding light is bright.

The auto light switch illuminates the display in all modes.

Turning the Auto Light Switch On and Off
In any mode, hold down the 

L

 button for about two seconds to

toggle the auto light switch on (auto light switch on indicator
displayed in the upper dial) and off (no indicator displayed).

Auto light switch 
on indicator

An LED is used to illuminate the display for easy reading in the
dark. An auto light switch automatically turns on illumination when
you angle the watch towards your face for reading.

Illuminating the Display Manually

Press the 

L

L

L

L

L

 button in any

mode to illuminate the display.

You can use the procedure under
“Specifying the Illumination
Duration” to configure the
illumination duration as
approximately 1.5 seconds or 2.5
seconds.

Pressing the 

L

 button

illuminates the display regardless
of whether the auto light switch is
on or off.

You may hear a faint rattling sound when you move the watch
around. This sound is caused by the movement of a metal
bulb that controls operation of the auto light switch, and does
not indicate malfunction.

Содержание 3334

Страница 1: ...d Date Leaving the watch in a drawer or anywhere else it is dark can cause the power saving mode to trigger in order to conserve battery power Power Saving Each press of the C C C C C button sounds a confirmation tone and cycles through available modes in the sequence shown below The watch will automatically revert to the Timekeeping Mode if you leave it in the Alarm Mode or Hand Setting Mode with...

Страница 2: ...tomatically disabled whenever battery power is at Level 3 or lower The display may illuminate unintentionally when you wear the watch on the inside of your wrist when you shake your arm or when you raise your arm Be sure to turn off the auto light switch whenever you do not need illumination Keep the auto light switch turned off whenever you are wearing the watch on the inside of your wrist Electr...

Страница 3: ...s a radio controlled watch Your radio controlled watch is designed to receive a time calibration signal that contains standard time data and adjust its current time setting accordingly Signal is received using built in antenna Signal Data Cesium Atomic Clock Transmitter Long wave Calibration Signal Internally Decode Watch Time Data Watch decodes received data and converts it to time data Time is a...

Страница 4: ... are two methods you can use to receive the time calibration signal Auto receive Reception is performed automatically at midnight 1 00 2 00 3 00 and 4 00 each morning Manual receive You initiate reception using a button operation If reception is not successful for any of the normal auto receive times shown above auto receive is performed one more time at 5 00 a m The watch is set up for auto recep...

Страница 5: ...icon appears after the watch successfully receives the calibration signal and adjusts the current time setting A single receive operation was not successful The watch is not in the Timekeeping Mode or World Time Mode when an auto reception time is reached You performed manual reception which clears the receive icon from the display Corrective Measures Check to make sure the watch is in a location ...

Страница 6: ...peat causes timing to restart from the start time when the end of the countdown is reached The countdown repeats up to 10 times or until you stop it manually Configuring Timer Settings 1 In the Timer Mode hold down A A A A A for about one second until the minute digits of the timer start time start to flash in the bottom dial This is the setting screen 2 Use the D D D D D and B B B B B buttons to ...

Страница 7: ...the bottom dial but timing of the next split continues internally Changing to another mode while a split time is displayed cancels the split time operation Pressing the B button while timing is stopped resets the stopwatch to all zeros Using the Stopwatch Forward Back TYO Tokyo 12 24 hour format Resets to 00 seconds Forward Back Hour Minutes The stopwatch measures elapsed time in units of 1 100 se...

Страница 8: ...een automatically if you do not perform any operation for about two or three minutes Digital Analog Synchronization The watch automatically adjusts its analog setting to match the current digital time setting When adjusting the analog time the watch always moves the hands forward clockwise direction Depending on how different the digital and analog time settings are it may take some time for the a...

Отзывы: