Casio 3260 Скачать руководство пользователя страница 10

Operation Guide 3260 3280

E-90

Using the Stopwatch

The stopwatch measures elapsed time, split times, and two finishes.

To enter the Stopwatch Mode

Use

D

 to select the Stopwatch Mode (

STW

) as shown on 

page E-36.

 About one second after 

STW

 appears on the display, 

the display will change to show the stopwatch hours.

To perform an elapsed time operation

E

E

E

E

A

Start

Stop

(Restart)

(Stop)

Reset

Hours

1/100 second

Seconds

Minutes

Current time

Hours

1/100 second

Seconds

Minutes

Current time

E-91

To pause at a split time

E

A

A

E

A

Start

Split

(

SPL

 displayed)

Split release

Stop

Reset

To measure two finishes

E

A

E

A

A

Start

Split

First runner 
finishes.
Display time of 
first runner

Stop

Second runner 
finishes.

Split release

Display time of 
second runner

Reset

E-92

Note

 The Stopwatch Mode can indicate elapsed time up to 999 hours, 59 minutes, 59.99 

seconds.

 Once started, stopwatch timing continues until you press 

A

 to stop it, even if you 

exit the Stopwatch Mode to another mode and even if timing reaches the stopwatch 
limit defined above.

 Exiting the Stopwatch Mode while a split time is frozen on the display clears the 

split time and returns to elapsed time measurement.

E-93

Using the Countdown Timer

The countdown timer can be configured to start at a preset time, and sound an alarm 
when the end of the countdown is reached.

To enter the Countdown Timer Mode

Use

D

 to select the Countdown Timer Mode (

TMR

) as 

shown on page E-36.

 About one second after 

TMR

 appears on the display, 

the display will change to show the countdown time 
hours.

Current time

Countdown time 
(Hour, minutes, seconds)

Current time

Countdown time 
(Hour, minutes, seconds)

E-94

To specify the countdown start time

1. Enter the Countdown Timer Mode.

 If a countdown is in progress (indicated by the seconds counting down), press 

E

 to stop it and then press 

A

 to reset to the current countdown start time.

 If a countdown is paused, press 

A

 to reset to the current countdown start 

time.

2. Hold down 

A

 until the hour setting of the current countdown start time starts to 

flash. This is the setting screen.

3. Press 

D

 to move the flashing between the hour and minute settings.

4. Use 

E

 (+) and 

B

 (–) to change the flashing item.

 To set the starting value of the countdown time to 24 hours, set 

0H 00’00

.

5. Press 

A

 to exit the setting screen.

E-95

To perform a countdown timer operation

E

E

E

E

A

Start

Stop

(Restart)

(Stop)

Reset

 Before starting a countdown timer operation, check to make sure that a countdown 

operation is not in progress (indicated by the seconds counting down). If it is, press 

E

 to stop it and then 

A

 to reset to the countdown start time.

 An alarm sounds for ten seconds when the end of the countdown is reached. This 

alarm will sound in all modes. The countdown time is reset to its starting value 
automatically when the alarm sounds.

To stop the alarm

Press any button.

E-96

Using the Alarm

You can set four one-time alarms and one snooze alarm. 
When an alarm is turned on, the watch will beep for about 
10 seconds each day when the time in the Timekeeping 
Mode reaches the preset alarm time. This is true even if 
the watch is not in the Timekeeping Mode.
You can also turn on an Hourly Time Signal, which will 
cause the watch to beep twice every hour on the hour.

To enter the Alarm Mode

Use

D

 to select the Alarm Mode (

ALM

) as shown on 

page E-36.

 About one second after 

ALM

 appears on the display, 

the display will change to show one of the following 
alarm screens: 

AL1

 (Alarm 1) through 

AL4

 (Alarm 4), 

SNZ

 (snooze alarm), or 

SIG

 (Hourly Time Signal).

Alarm time 
(Hour : Minutes)

Current time

llll

llll

l

l

Alarm time 
(Hour : Minutes)

Current time

llll

llll

l

l

E-97

 When you enter the Alarm Mode, the screen you were viewing when you last exited 

the mode appears first.

To set an alarm time

1. In the Alarm Mode, use 

E

 to scroll through the alarm 

screens until the one whose time you want to set is 
displayed.

AL1

AL2

AL3

SIG

SNZ

AL4

2. Hold down 

A

 until the alarm time starts to flash. This is 

the setting screen.

3. Press 

D

 to move the flashing between the hour and 

minute settings.

Alarm ON/OFF 
indicator

llll

llll

l

l

Alarm ON/OFF 
indicator

llll

llll

l

l

E-98

4. While a setting is flashing, use 

E

 (+) and 

B

 (–) to change it.

 When setting the alarm time using the 12-hour format, take care to set the time 

correctly as a.m. (no indicator) or p.m. (

P

 indicator).

5. Press 

A

 to exit the setting screen.

To test the alarm

In the Alarm Mode, hold down 

E

 to sound the alarm.

To turn an alarm and the Hourly Time Signal on and off

1. In the Alarm Mode, use 

E

 to select an alarm or the Hourly Time Signal.

E-99

2. When the alarm or the Hourly Time Signal you want is selected, press 

A

 to turn it 

on and off.

 The alarm on indicator and hourly time signal on 

indicator are displayed when the alarm and/or 
signal is turned on.

 The alarm on indicator and the Hourly Time Signal 

on indicator are shown on the display in all modes 
while these functions are turned on.

 If any alarm is on, the alarm on indicator is shown 

on the display in all modes.

 The alarm on indicator flashes while the alarm is 

sounding.

 The snooze alarm indicator (

SNZ

) flashes while the 

snooze alarm is sounding and during the 5-minute 
intervals between alarms.

To stop the alarm

Press any button.

Hourly time 
signal on 
indicator

Alarm on 
indicator

llll

llll

l

l

Hourly time 
signal on 
indicator

Alarm on 
indicator

llll

llll

l

l

Содержание 3260

Страница 1: ...ception and World Time Mode data depend on correct Home City time and date settings in the Timekeeping Mode Make sure you configure these settings correctly 3 Set the current time To set the time using a time calibration signal See To get ready for a receive operation page E 26 To set the time manually See Configuring Current Time and Date Settings Manually page E 45 The watch is now ready for use...

Страница 2: ...ore using it Leaving the watch exposed to direct sunlight or some other very strong light source can cause the battery power indicator to show a reading temporarily that is higher than the actual battery level The correct battery level should be indicated after a few minutes All data stored in memory is deleted and the current time and all other settings return to their initial factory defaults wh...

Страница 3: ...ters 310 miles Fort Collins United States transmitter 600 miles 1 000 kilometers Fukushima or Fukuoka Saga Japan transmitters 500 kilometers 310 miles Shangqiu China transmitter 500 kilometers 310 miles As of January 2011 China does not use Daylight Saving Time DST If China does go to the Daylight Saving Time system in the future some functions of this watch may no longer operate correctly E 25 Wh...

Страница 4: ...eration is being performed When the watch is in the function sleep state Power Saving page E 18 While a countdown timer operation is in progress page E 93 A receive operation is cancelled if an alarm sounds while it is being performed The Home City setting reverts to the initial default of TOKYO whenever the battery power level drops to Level 5 or when you have the rechargeable battery replaced If...

Страница 5: ...s selected as the Home City While Auto DST is selected the DST setting will be changed automatically in accordance with time calibration signal data l l l l l l l l l lll l l l l l l l l l l DST indicator l l l l l l l l l lll l l l l l l l l l l DST indicator E 44 4 After all the settings are the way you want press A to return to the Timekeeping Mode The DST indicator appears to indicate that Day...

Страница 6: ...you should input 7 In the case of 7 6 input 8 for 7 5 you can input 7 or 8 Bidirectional Calibration and Northerly Calibration Bidirectional calibration and northerly calibration calibrate the accuracy of the bearing sensor in relation to magnetic north Use bidirectional calibration when you want to take readings within an area exposed to magnetic force This type of calibration should be used if t...

Страница 7: ...at direction To set a map and find your current location 1 With the watch on your wrist position it so the face is horizontal 2 Press C to take a compass reading The reading will appear on the display after about two seconds E 65 3 Rotate the map without moving the watch so the northerly direction indicated on the map matches north as indicated by the watch If the watch is configured to indicate m...

Страница 8: ...outside the range of 10 0 C to 60 0 C 14 0 F to 140 0 F The temperature value will reappear as soon as the measured temperature is within the allowable range Display Units You can select either Celsius C or Fahrenheit F for the displayed temperature value See To specify the temperature unit page E 77 for more information Temperature Sensor Calibration The watch s temperature sensor is calibrated a...

Страница 9: ...rsed from the actual Moon as viewed from your location you can use the procedure under To reverse the displayed Moon phase page E 83 to change the indicator Moon Phase Indicator Module 3260 Module 3280 Moon Phase Indicator Module 3260 Module 3280 E 85 Moon Phase Indicator Moon Phase Moon Age Module 3260 Module 3280 1 0 2 7 2 8 4 6 4 7 6 4 6 5 8 3 8 4 10 1 10 2 12 0 12 1 13 8 New Moon First Quarter...

Страница 10: ...t to the countdown start time An alarm sounds for ten seconds when the end of the countdown is reached This alarm will sound in all modes The countdown time is reset to its starting value automatically when the alarm sounds To stop the alarm Press any button E 96 Using the Alarm You can set four one time alarms and one snooze alarm When an alarm is turned on the watch will beep for about 10 second...

Страница 11: ... Frequent display illumination can run down the battery quickly and require charging The following guidelines give an idea of the charging time required to recover from a single illumination operation Approximately five minutes exposure to bright sunlight coming in through a window Approximately 50 minutes exposure to indoor fluorescent lighting Auto light switch on indicator Auto light switch on ...

Страница 12: ...a train boat etc What causes different direction readings to produce different results at the same location Magnetism generated by nearby high tension wires is interfering with detection of terrestrial magnetism Move away from the high tension wires and try again Why am I having problems taking direction readings indoors A TV personal computer speakers or some other object is interfering with terr...

Страница 13: ... 31 time zones Other Daylight Saving Time Standard Time Stopwatch Measuring unit 1 100 second Measuring capacity 999 59 59 99 Measuring modes Elapsed time split time two finishes Countdown Timer Measuring unit 1 second Countdown start time setting range 1 minute to 24 hours 1 hour increments and 1 minute increments Alarms 5 daily alarms four one time alarms one snooze alarm Hourly Time Signal Illu...

Отзывы: