Casio 3249 Скачать руководство пользователя страница 2

2

Operation Guide 3249

Reference

This section contains more detailed and technical information about watch operation.
It also contains important precautions and notes about the various features and
functions of this watch.

Button Operation Tone

The button operation tone sounds any time you press one
of the watch’s buttons. You can turn the button operation
tone on or off as desired.

Even if you turn off the button operation tone, the alarm,

Hourly Time Signal, and Countdown Timer Mode alarm
all operate normally.

To turn the button operation tone on and off

In any mode (except when a setting screen is on the
display), hold down 

C

 for about three seconds to toggle

the button operation tone on (mute indicator not
displayed) and off (mute indicator displayed).

Holding down 

C

 to turn the button operation tone on or off also causes the watch’s

current mode to change.

The mute indicator is displayed in all modes when the button operation tone is
turned off.

Scrolling

The 

B

 and 

D

 buttons are used in various modes and setting screens to scroll

through data on the display. In most cases, holding down these buttons during a scroll
operation scrolls at high speed.

Initial Screens

When you enter the World Time or Alarm Mode, the data you were viewing when you
last exited the mode appears first.

World Time

The seconds count of the World Time is synchronized with the seconds count of the
Timekeeping Mode.

The current time in all World Time Mode cities is calculated in accordance with the
Greenwich Mean Time (GMT) differential for each city, based on the current Home
City time setting in the Timekeeping Mode.

The GMT differential is the time difference of the time zone where the city is located
from Greenwich Mean Time.

GMT differential is calculated by this watch based on Universal Time Coordinated
(UTC) data.

Countdown Timer

The countdown timer can be set within a range of
one minute to 24 hours. An alarm sounds when the
countdown reaches zero.

The countdown operation continues even if you exit the
Countdown Timer Mode.

All of the operations in this section are performed in the
Countdown Timer Mode, which you enter by pressing

C

.

To use the countdown timer

Press 

D

 while in the Countdown Timer Mode to start the

countdown timer.

When the end of the countdown is reached, the alarm
sounds for 10 seconds or until you stop it by pressing
any button. The countdown time is reset to its starting
value automatically after the alarm stops.

Press 

D

 while a countdown operation is in progress to pause it. Press 

D

 again to

resume the countdown.

To stop a countdown operation completely, first pause it (by pressing 

D

), and then

press 

A

. This returns the countdown time to its starting value.

To set the countdown start time

1. In the Countdown Timer Mode, hold down 

A

 until the

hours of the countdown start time start to flash, which
indicates the setting screen.

2. Press 

C

 to move the flashing between the hours and

minutes.

3. While a setting is flashing, use 

D

 (+) or 

B

 (–) to

change it.

To set the starting value of the countdown time to
24 hours, set 

0:00

.

4. Press 

A

 to exit the setting screen.

Stopwatch

The stopwatch lets you measure elapsed time, split times,
and two finishes.

The display range of the stopwatch is 23 hours,
59 minutes, 59.99 seconds.

The stopwatch continues to run, restarting from zero
after it reaches its limit, until you stop it.

The stopwatch measurement operation continues even
if you exit the Stopwatch Mode.

Exiting the Stopwatch Mode while a split time is frozen
on the display clears the split time and returns to
elapsed time measurement.

All of the operations in this section are performed in the
Stopwatch Mode, which you enter by pressing 

C

.

Elapsed time measurement 

Stop

Re-start

Stop

Clear

Start

Start

Split

(

SPL

 displayed)

Split release

Stop

Clear

Start

Split

Stop

Split release

Clear

Split time measurement 

Split time and 1st-2nd place times

First runner 
finishes.
Display time of 
first runner.

Second runner 
finishes.

Display time of 
second runner.

4. While a setting is flashing, use 

D

 (+) and 

B

 (–) to change it.

When setting the alarm time using the 12-hour format, take care to set the time
correctly as a.m. (

AM

 indicator) or p.m. (

PM

 indicator).

5. Press 

A

 to exit the setting screen.

Alarm Operation

The alarm sounds at the preset time for about 10 seconds, regardless of the mode the
watch is in.

To stop the alarm tone after it starts to sound, press any button.

To test the alarm

In the Alarm Mode, hold down 

D

 to sound the alarm.

To turn an alarm on and off

1. In the Alarm Mode, use 

D

 to select an alarm.

2. Press 

A

 to toggle it on (the alarm on indicator

displayed) and off (the alarm on indicator not
displayed).

Turning on a daily alarm (

x1

 through 

x5

) displays the

alarm on indicator on its Alarm Mode screen.

In all modes, the alarm on indicator is shown for any
alarm that is currently turned on.

To turn the Hourly Time Signal on and off

1. In the Alarm Mode, use 

D

 to select the Hourly Time

Signal (

SIG

).

2. Press 

A

 to toggle it on (the hourly time signal on

indicator displayed) and off (the hourly time signal on
indicator not displayed).

The Hourly Time Signal on indicator is shown on the
display in all modes while the Hourly Time Signal is
turned on.

Hourly time signal 
on indicator 

Alarm on indicator 

 Mode indicator 

1/100 second 

Hours Seconds 

Minutes 

Hours Seconds 

Minutes 

 Mode indicator 

Mute indicator 

Specifications

Accuracy at normal temperature: 

±

30 seconds a month

Timekeeping: 

Hour, minutes, seconds, a.m./p.m., day, day of the week, month, year

Time system: Switchable between 12-hour and 24-hour formats
Calendar system: Full auto-calendar pre-programmed from the year 2000 to 2099
Standard time/Daylight saving time
Other: Home City code (can be assigned one of 30 city codes); Daylight Saving

Time (summer time)/Standard Time

World Time:

 30 cities (29 time zones)

Other: Daylight Saving Time/Standard Time

Alarm: 

5 Daily Alarms, Hourly Time Signal

Stopwatch

Measuring unit: 1/100 of a second
Measuring capacity: 23 hours, 59 minutes, 59.99 seconds
Functions: Elapsed time, split time and two finishes

Countdown Timer

Measuring unit: 1 second
Input range: 1 minute to 24 hours (1-minute increments and 1-hour increments)

Other: 

Two LEDs (light-emitting diodes), Button operation tone on/off

Battery: 

One lithium battery (Type: CR1616)

Battery life

3 years under the following conditions

 2 seconds of illumination operation per day

 10 seconds of alarm operation per day

Отзывы: