Casio 3143 Скачать руководство пользователя страница 4

Operation Guide 3143

4

Temperature is displayed in units of 0.1

°

C (or 0.2

°

F).

The displayed temperature value changes to 

xxx

 

°

C (or 

°

F) if a measured

temperature falls outside the range of –10.0

°

C to 60.0

°

C (14.0

°

F to

140.0

°

F). The temperature value will reappear as soon as the measured

temperature is within the allowable range.

In some areas, barometric pressure is expressed in millibars (mb) instead
of hectopascals (hPa). It really makes no difference, because 1hPa = 1mb.

You can select either hectopascals (hPa) or inchesHg (inHg) as the display
unit for the measured barometric pressure, and Celsius  (

°

C)  or Fahrenheit

(

°

F) as the display unit for the measured temperature value. See “To select

the temperature, altitude, and barometric pressure units”.

See “Barometer and Thermometer Precautions” for important precautions.

Barometric Pressure Graph

Barometric pressure indicates changes in the atmosphere. By monitoring
these changes you can predict the weather with reasonable accuracy.
This watch takes barometric pressure measurements automatically every two
hours (at the top of each even-numbered hour), regardless of its current
mode. Measurement results are used to produce barometric pressure graph
and barometric pressure differential pointer readings.
The barometric pressure graph shows readings of previous measurements for
up to 24 hours. The horizontal axis of the graph represents time, with each dot
standing for two hours. The rightmost dot represents the most recent reading.
The vertical axis of the graph represents barometric pressure, with each dot
standing for the relative difference between its reading and that of the dots
next to it. Each dot represents 1hPa.
The following shows how to interpret the data that appears on the barometric
pressure graph.

A rising graph generally means improving weather.

A falling graph generally means deteriorating weather.

Note that if there are sudden changes in barometric
pressure or temperature, the graph line of past
measurements may run off the top or bottom of the display.
The entire graph will become visible once barometric
conditions stabilize.
The following conditions cause the barometric pressure
measurement to be skipped, with the corresponding point on
the barometric pressure graph being left blank.

Barometric reading that is out of range (260 hPa/mb to 1,100 hPa/mb or
7.65 inHg to 32.45 inHg)

Sensor malfunction

Not visible on
the display.

Barometric Pressure Differential Pointer

This pointer indicates the relative difference between the most recent
barometric pressure reading indicated on the barometric pressure graph, and
the current barometric pressure value displayed in the Barometer/
Thermometer Mode.

Pressure differential is indicated in the range of 

±

5 hPa, in 1-hPa units.

The barometric pressure differential pointer is not displayed when the
displayed current barometric value is outside of the allowable measurement
range (260 to 1,100 hPa).

Barometric pressure is calculated and displayed using hPa as the standard.
The barometric pressure differential also can be read in inHg units as
shown in the illustration.

Pressure differential
examples in the
illustration are indicated
in 3 hPa/0.1 inHg steps.

Current pressure less
than most recent
measured pressure

Current pressure greater
than most recent
measured pressure

Barometric pressure
differential

inHg values

hPa values

About Barometric and Temperature Measurements

Barometric pressure and temperature measurement operations are
performed as soon as you enter the Barometer/Thermometer Mode. After
that, barometric pressure and temperature measurements are taken every
five seconds.

You also can perform a barometric pressure and temperature measurement
at any time by pressing 

B

 in the Barometer/Thermometer Mode.

Altimeter

The watch’s altimeter uses a pressure sensor to detect current air pressure,
which is then used to estimate the current altitude based on ISA (International
Standard Atmosphere) preset values. You also can specify a reference
altitude, which the watch will use to calculate your current altitude based on
the value you specify. Altimeter functions also include storage of
measurement data in memory.
You also can measure the altitude differential (change) from a specific
reference altitude. Specifying the reference altitude is as simple as pressing a
single button to reset the reference altitude to zero.

Important!

This watch estimates altitude based on air pressure. This means that
altitude readings for the same location may vary if air pressure changes.

The semiconductor pressure sensor used by the watch for altitude
measurements also is affected by temperature. When taking altitude
measurements, make sure the watch is not subjected to temperature
changes.

To avoid the effect of sudden temperature changes during measurement,
keep the watch on your wrist in direct contact with your skin.

Do not rely upon this watch for altitude measurements or perform button
operations while sky diving, hang gliding, or paragliding, while riding a
gyrocopter, glider, or any other aircraft, or while engaging in any other
activity where there is the chance of sudden altitude changes.

Do not use this watch for measuring altitude in applications that demand
professional or industrial level precision.

Remember that the air inside of a commercial aircraft is pressurized.
Because of this, the readings produced by this watch will not match the
altitude readings announced or indicated the flight crew.

How the Altimeter Measures Altitude

The altimeter can measure altitude based on its own preset values, or a
reference altitude specified by you.

When you measure altitude based on preset values

Data produced by the watch’s barometric pressure sensor is converted to
approximate altitude based on ISA (International Standard Atmosphere)
conversion values stored in watch memory.

When you measure altitude using a reference altitude specified by you

After you specify a reference altitude, the watch uses that value to convert the
current measured barometric pressure value to altitude.

When mountain climbing, you can set the
reference value in accordance with a marker
along the way or altitude information from a
map. After that, the altitude readings
produced by the watch will be more accurate
than they would without a reference altitude.

Displaying Your Current Altitude

You can use the procedure described in this section to display your current
altitude. If you leave the watch in the Altimeter Mode, it will update the
displayed altitude value regularly, and indicate reading-to-reading changes in
the altitude graph at the top of the display.

400

B

A

The Altimeter Mode gives you a choice of four different display formats. The
format you choose determines what type of data is displayed. The Altimeter
Mode screen can show any three of the following four items: altitude graph,
altitude value, altitude differential, and the current time. You also can select
either of the following two altitude measurement types.

0’05

: Readings at five-second intervals for one hour

2’00

: Readings at five-second intervals for the first three minutes followed

by two-minute intervals for approximately nine or 10 hours

For information about configuring settings for the altitude reading interval
and duration, see “To select the altitude measurement type”.

Important!

The procedure in this section simply displays values indicating your current
altitude, without storing them in watch memory. For information about
recording altitude readings in watch memory, see “Saving Altitude Data”.

To display your current altitude

1. Press 

D

 in the Timekeeping Mode or

Barometer/Thermometer Mode to enter the
Altimeter Mode.

The watch will start altitude measurement
automatically, and display the result.

It can take up to four or five seconds for the
altitude reading to appear after you enter
the Altimeter Mode.

2. If you want the altitude value and altitude

graph to be updated in accordance with the
altitude measurement type (interval and
duration) you have selected, leave the watch
in the Altimeter Mode.

If you want to restart the altitude measurement
operation at any point, press 

D

.

3. To stop the altitude measurement operation,

press 

C

 to exit the Altimeter Mode.

Current altitude

Altitude graph

Current time

Altitude differential
pointer

Содержание 3143

Страница 1: ...aking measurements that require professional or industrial precision Values produced by this watch should be considered as reasonable representations only CASIO COMPUTER CO LTD assumes no responsibility for any loss or any claims by third parties that may arise through the use of this watch Applications The built in sensors of this watch measure barometric pressure temperature and altitude Measure...

Страница 2: ...ot perform any button operations or move the watch during this time Inside or among buildings Inside a vehicle Near a construction site airport or other sources of electrical noise Near high tension power lines Among or behind mountains Near household appliances office equipment or a mobile phone The time calibration signal the watch will attempt to pick up depends on its current Home City code se...

Страница 3: ...no reception has been successful To turn auto receive on and off 1 Enter the Receive Mode 2 In the Receive Mode hold down A until the current auto receive setting ON or OFF starts to flash This is the setting screen Note that the setting screen will not appear if the currently selected Home City is one that does not support time calibration reception 3 Press D to toggle auto receive on ON and off ...

Страница 4: ...r current altitude based on the value you specify Altimeter functions also include storage of measurement data in memory You also can measure the altitude differential change from a specific reference altitude Specifying the reference altitude is as simple as pressing a single button to reset the reference altitude to zero Important This watch estimates altitude based on air pressure This means th...

Страница 5: ...tored You can recall saved records using the Data Recall Mode Periodic Records Periodic records of up to 40 altitude readings are taken during a save session You can use the Data Recall Mode to view these records How periodic records are created and saved The following operation is performed simultaneously with the operation described under How current session record data is updated a The watch cr...

Страница 6: ...he view periodic records and current session record that are in watch memory Altitude data records are created and stored in the Altimeter Mode Data Screens The following explains the contents of each of the screens that appear in the Data Recall Mode Note While the periodic record high altitude or low altitude screen is displayed the bottom part of the display alternates between the measurement d...

Страница 7: ...ations in this section are performed in the Alarm Mode which you enter by pressing C Alarm time Hour Minutes Alarm number Current time To set an alarm time 1 In the Alarm Mode use D and B to scroll through the alarm screens until the one whose time you want to set is displayed 2 Hold down A until the hour setting of the alarm time start to flash which indicates the setting screen This automaticall...

Страница 8: ...wrist in order to eliminate the effects of body heat In the case of altitude measurement on the other hand it is better to leave the watch on your wrist because doing so keeps the watch at a constant temperature which contributes to more accurate altitude measurements To give altitude measurement priority leave the watch on your wrist or in any other location where the temperature of the watch is ...

Страница 9: ...udy Day 5 000 lux Indoor Fluorescent Lighting 500 lux Timekeeping Use the Timekeeping Mode to set and view the current time and date Pressing A while in the Timekeeping Mode will cycle through the Timekeeping Mode display formats as shown below Day of week Day Day of the Week Day Screen PM indicator Hour Minute Second Year Month Day Date Screen Barometric Pressure Graph Screen Day Barometric press...

Страница 10: ... tone on not displayed and off displayed Since the C button is also the mode change button holding it down to turn the button operation on or off also causes the watch s current mode to change The mute indicator is displayed in all modes when the button operation tone is turned off Power Saving When turned on Power Saving enters a sleep state automatically whenever the watch is left for a certain ...

Страница 11: ... back towards your face again If this does not work drop your arm all the way down so it hangs at your side and then bring it back up again Under certain conditions illumination does not turn on until about one second after you turn the face of the watch towards you This does not necessarily indicate malfunction You may notice a very faint clicking sound coming from the watch when it is shaken bac...

Страница 12: ...AR BER Athens Cairo Jerusalem Jeddah Tehran Dubai Kabul Karachi Delhi Dhaka Yangon Bangkok Hong Kong Seoul Tokyo Adelaide Sydney Noumea Wellington 02 0 03 0 03 5 04 0 04 5 05 0 05 5 06 0 06 5 07 0 08 0 09 0 09 5 10 0 11 0 12 0 Helsinki Istanbul Beirut Damascus Cape Town Kuwait Riyadh Aden Addis Ababa Nairobi Moscow Shiraz Abu Dhabi Muscat Male Mumbai Kolkata Colombo Jakarta Phnom Penh Hanoi Vienti...

Отзывы: