Positioning Your Arm Correctly

You should be wearing the watch on the outside of your wrist
when using the full auto light switch.

Make sure that the left (9 o’clock)
and right (3 o’clock) sides of the
watch are within 

±

15 degrees of

being parallel with the ground.
The full auto light switch may not
operate properly if the angle is
greater than 15 degrees.

Illumination Precautions

The light may be difficult to see under bright sunlight.

Illumination turns off automatically if an alarm sounds, etc.

You may notice a slight sound from the watch while
illumination is turned on. This is the sound of EL panel
vibration and does not indicate malfunction.

Illumination is disabled during time calibration signal
reception, while configuring sensor measurement mode
settings, and during direction sensor calibration
(“Calibrating the Direction Sensor”).

Full Auto Light Switch Precautions

Frequent use of the full auto light switch can run down the battery.

The full auto light switch may turn on illumination when the face of
the watch is shaded by your sleeve.

Illumination may not turn on immediately when you angle the
watch towards your face. This does not indicate malfunction.

Illumination remains on for the specified duration (1.5 seconds or
2.5 seconds) only, even if you leave the watch angled towards
your face.

The full auto light switch is disabled automatically whenever the
battery indicator reaches Level 4.

Illumination may turn on unintentionally when you wear the watch
on the inside of your wrist, when you shake your arm, or when
you raise your arm.

 Be sure to turn off the full auto light switch

whenever you do not need illumination

.

Keep the full auto light switch turned off whenever you are
wearing the watch on the inside of your wrist.

Electro-static charge and magnetism can interfere with full auto
light switch operation and even make operation impossible. If this
happens, lower your arm to the starting position and then raise it
again. If you still have trouble with illumination, try lowering your
arm down to your side and then raise it to your face for reading.

The full auto light switch is disabled during the 20 seconds
required to take a direction reading with the digital compass.

With the watch on your
wrist, position it parallel
with the ground.

Rotate your arm so the watch
is angled at about 40 degrees,
so you can read its face.

1

1

1

1

1

2

2

2

2

2

An EL (electro luminescent) panel is used for illumination for easy
reading in the dark. A full auto light switch turns on illumination
automatically when you angle the watch towards your face for
reading.

To turn on illumination manually

In any mode, press the 

L

L

L

L

L

button.

You can specify 1.5 seconds or
2.5 seconds as the duration of
display illumination (“To specify
the illumination duration”).

Pressing the 

L

 button turns on illumination regardless of

whether the full auto light switch is on or off.

You may hear a faint rattling sound when you move the watch
around. This sound is caused by the movement of a metal
bulb that controls operation of the full auto light switch, and
does not indicate malfunction.

To turn the full auto light switch on or off

The full auto light switch turns on illumination automatically
whenever you angle the watch towards your face for reading,
but only when it is dark.

The full auto light switch does not turn on illumination when
surrounding light is bright.

The full auto light switch turns on illumination for the specified
illumination duration in all modes when the watch is angled
towards the face.

In any mode (except when a setting screen is on the display), hold
down the 

L

 button for about three seconds to toggle the full auto

light switch on (

 indicator displayed) and off (no indicator

displayed).

(3 seconds)

Full Auto Light 
Switch On Indicator

Illumination

To specify the illumination duration

1.

In the Timekeeping Mode,
hold down the 

E

E

E

E

E

 button

for about two seconds
until the city code and
GMT differential start to
flash. This is the setting
screen.

2.

Press the 

D

D

D

D

D

 button three

times so the seconds are
flashing.

3.

Press the 

A

A

A

A

A

 button to

toggle the display
illumination between 1.5
seconds and 2.5 seconds.

  

: 1.5 seconds

: 2.5 seconds

4.

When the setting is the
way you want, press the

E

E

E

E

E

 button to exit the

setting screen.

The display also will exit the
setting screen automatically if
you do not perform any
operation for about two or
three minutes.

City Code

(2 seconds)

(3 times)

1.5 Seconds

2.5 Seconds

At least 40
degrees

Содержание 2891

Страница 1: ...re Check changes in barometric pressure to get an idea of what kind of weather to expect See Taking Pressure and Temperature Readings for more information Before getting started Pressure Tendency Graph Temperature Pressure Temperature Mode Barometric Pressure Pressure Differential Graphic Altitude Graph Altitude Current Time Altitude Mode Altitude Differential Graphic Digital Compass Current Time ...

Страница 2: ...econds when the end of the countdown is reached The stopwatch performs 1 100 second elapsed time measurement up to 9 hours 59 minutes 59 99 seconds 10 hours Modes and Display Screens Power Saving causes the watch to enter a sleep state automatically in order to save power whenever it is left in the dark The Power Saving feature of the watch is turned on at the factory Note that the watch may also ...

Страница 3: ...mpass Blank Blank Blank During Readings Normal operation should return after battery power recovers Charging Guide Starting from a full charge the watch should be able to continue operating for about five months without further charging under the example conditions described below Example Daily Use Illumination 1 5 seconds day Alarms 10 seconds day Direction Reading 10 times week Altitude Readings...

Страница 4: ...ring the 20 seconds required to take a direction reading with the digital compass With the watch on your wrist position it parallel with the ground Rotate your arm so the watch is angled at about 40 degrees so you can read its face 1 1 1 1 1 2 2 2 2 2 An EL electro luminescent panel is used for illumination for easy reading in the dark A full auto light switch turns on illumination automatically w...

Страница 5: ... Press the C C C C C button All other buttons besides C are disabled during signal reception When reception is successful The watch terminates reception and adjusts the current time Next it beeps and then displays the date and time the adjustment was performed The icon with all numbered segments visible on the display also indicates successful signal reception When reception fails The watch does n...

Страница 6: ...ng or other problems Are you within the reception range of a transmitter See Reception Ranges for information about areas where the watch can receive the signal Is there something in the immediate area that may be interfering with reception Even if you are within the reception range of a transmitter objects between you and the transmitter or electrical noise can interfere with reception Avoid such...

Страница 7: ...gs If this happens perform 2 point calibration To perform 2 point calibration to correct the readings If you are unsure if you watch has been exposed to magnetism perform 2 point calibration before taking a direction reading Exposing the watch to extremely strong magnetism can make correct direction readings impossible even after 2 point calibration or can cause display of abnormal values during d...

Страница 8: ...n or due to some other reason If this happens perform the calibration procedure again from the beginning Take care that you do not move the watch while calibration is being performed If ERR or abnormal value detected keeps appearing when you try to perform calibration it could mean that there is a strong source of magnetism close by If this happens move to another location and try performing calib...

Страница 9: ...compass to take approximate readings while riding in an automobile See To perform 2 point calibration for information about how to perform 2 point calibration Important Never try to perform 2 point calibration while driving Doing so is very dangerous and creates the risk of serious accident 1 First park the vehicle in a safe area where you can turn it around 180 degrees 2 At a location inside the ...

Страница 10: ...tton When measuring outdoor temperatures remove the watch from your wrist and place it in a location where its readings will not affected by body temperature sweat water droplets direct sunlight etc To turn the pressure differential graphic on and off 1 In the Pressure Temperature Mode hold down the E E E E E button for about two seconds until SET appears at the top of the display After about four...

Страница 11: ...rectly Using the wrong value can make it impossible to measure barometric pressure correctly 3 Use the C C C C C and A A A A A buttons to adjust the barometric pressure value Each press of the C button or A button changes the displayed value by 1hPa Holding down either button scrolls the setting at high speed Pressing the C and A buttons at the same time returns to the factory default setting whic...

Страница 12: ...ly Altitude Mode Display Altitude Graph ACT Indicator Altitude Current Time The altitude can take up to four or five seconds to appear after you enter the Altitude Mode Altitude Tendency Graph The altitude tendency graph shows past altitude values measured in the Altitude Mode Each plot on the graph represents 10 meters Altitude Readings After you enter the Altitude Mode the watch takes readings e...

Страница 13: ...ing takes readings every 15 minutes 00 15 30 45 minutes of each hour and stores them in memory Starting a new altitude recording operation automatically clears any existing altitude records in memory to make room for the new readings The watch stops altitude recording automatically after the 40th record is stored Altitude recording continues to be performed even if you change to another mode The R...

Страница 14: ...s the reference altitude setting screen if you do not perform any operation for about two or three minutes Reference Altitude 2 seconds If temperature reading accuracy is a priority If temperature accuracy is a priority remove the watch from your wrist so it is not affected by your body temperature Note however that removing the watch from your wrist will make altitude readings more prone to being...

Страница 15: ...er to have it checked If ERR appears 1 If ERR appears while you are taking a pressure altitude temperature or direction reading try taking the reading again If ERR appears again it probably means that the sensor is malfunctioning Take your watch to the nearest CASIO Service Center to have it checked If ERR disappears from the display right away check it could indicate the following 2 Regardless of...

Страница 16: ... seconds when the end of the countdown is reached Pressing any button while the beeper is sounding stops it Using the Timer Use the D D D D D button to enter the Timer Mode as shown under Modes and Display Screens To turn the progress beeper on or off In the Timer Mode countdown can be running or stopped press the A A A A A button to toggle the progress beeper on and off The indicator is on the di...

Страница 17: ...hour when summer time is turned on You can turn summer time on or off independently for each World Time Mode city Note however that you cannot change the summer time setting for the GMT Greenwich Mean Time zone If you turn on summer time for the city that you are using for your Home Time city summer time is also turned on in the Timekeeping Mode World Time City Code List City Code City Name HNL AN...

Страница 18: ...tton for about two seconds until the current city code flashes on the display Setting the Home City Time and Date 6 While the 12 24 hour setting is selected press the C C C C C button to toggle the timekeeping format between 12 hour 12H indicator and 24 hour 24H indicator 7 While the seconds are selected press the C C C C C button to reset them to 00 in accordance with the time signal on the radio...

Отзывы: