Operation Guide 2825
9
•
xxx
is shown on the display while calibration is being performed. When
calibration is complete,
OK
appears in the upper part of the display and
then the Digital Compass Mode screen (showing the angle value) appears.
•
If
---
appears and then changes to
ERR
(error) on the calibration
screen, it means that there is something wrong with the sensor. The
ERR
message will disappear after about one second. Try performing the
calibration operation again. If
ERR
keeps appearing, contact your original
dealer or nearest authorized CASIO distributor to have the watch checked.
To perform northerly calibration
1. While in the Digital Compass Mode, hold
down
A
for about one second until
x1x
appears on the display, which indicates the
setting screen.
2. Press
D
to start the northerly calibration
procedure.
•
At this time,
-N-
(north) appears on the
display.
ll
l l
l l l l
ll
3. Place the watch on a level surface, and position it so that its 12 o’clock
position points north (as measured with another compass).
4. Press
B
to start the calibration operation.
•
---
is shown on the display while calibration is being performed. When
calibration is complete,
OK
appears in the upper part of the display and
then the Digital Compass Mode screen (with 0
°
indicated as the angle
value) appears.
•
If
---
appears and then changes to
ERR
(error) on the calibration
screen, it means that there is something wrong with the sensor. About one
second after the
ERR
message appears,
-N-
will reappear. Try
performing the calibration operation again. If
ERR
keeps appearing,
contact your original dealer or nearest authorized CASIO distributor to have
the watch checked.
Calibrating the Temperature Sensor
The temperature sensor of this watch is calibrated at the factory before
shipment, and further adjustment is normally not required. If you notice
serious errors in the temperature readings produced by the watch, you can
calibrate the sensor to correct the errors.
Important!
Incorrectly calibrating the temperature sensor can result in incorrect readings.
Carefully read the following before doing anything.
•
Compare the readings produced by the watch with those of another reliable
and accurate thermometer.
•
If adjustment is required, remove the watch from your wrist and wait for 20
or 30 minutes to give the temperature of the watch time to stabilize.
To calibrate the temperature sensor
1. Enter the Barometer/Thermometer Mode.
2. Hold down
A
for about one second, until the
display goes blank.
3. Release
A
. After about three or four seconds,
either
OFF
or a temperature calibration
value (if one is set) will appear in the upper
part of the display. This is the setting screen.
4. Wait four or five seconds until either
OFF
or a barometric pressure
calibration value (if there is one set) appears in the center part of the display.
ll
lll
ll
l l l l l l ll
lll
5. After waiting four or five seconds, press
E
(+) or
B
(–) to change the
displayed temperature by 0.1
°
C (or 0.2
°
F).
•
Pressing
E
and
B
at the same time returns to the factory calibration
(
OFF
).
6. Press
A
to exit the setting screen.
Calibrating the Barometric Pressure Sensor
The pressure sensor of this watch is calibrated at the factory before shipment
and further adjustment is normally not required. If you notice serious errors in
the barometric pressure readings produced by the watch, you can calibrate
the sensor to correct the errors.
Important!
Incorrectly calibrating the barometric pressure sensor can result in incorrect
readings. Before performing the calibration procedure, compare the readings
produced by the watch with those of another reliable and accurate barometer.
To calibrate the pressure sensor
1. Enter the Barometer/Thermometer Mode.
2. Hold down
A
for about one second, until the
display goes blank.
3. Release
A
. After about three or four seconds,
either
OFF
or a temperature calibration
value (if one is set) will appear in the upper
part of the display. This is the setting screen.
4. Wait four or five seconds until either
OFF
or a
barometric pressure calibration value (if there
is one set) appears in the center part of the
display.
ll
lll
ll
l l l l l l ll
lll
5. After waiting four or five seconds, press
D
to
move the flashing to the pressure sensor
calibration setting.
•
At this time,
OFF
or the barometric pressure
value should be flashing on the display.
6. Press
E
(+) or
B
(–) to change the displayed barometric pressure by 1
hPa (0.05 inHg).
•
Pressing
E
and
B
at the same time returns to the factory calibration
(
OFF
).
7. Press
A
to exit the setting screen.
ll
ll
ll
ll
ll
l l
l l l l
l l l l l
l l
ll
lll
ll
To manually reset the reference depth to 0 meters (feet)
In the Depth Gauge Mode, press
D
and
E
at
the same time.
Important!
•
This resets the reference depth and causes the
displayed depth to change to 0 meters (feet).
•
Never perform the above operation while
submerged.