Cashtester CT 332 SD
- 6 -
3.4 Alert messages
Self-test error code display
The detector automatically performs a self-test after each power on. If one of the following alert
messages is displayed, usually it is because the sensor is blocked by banknotes or dust. Please use a
brush or a piece of soft cloth to clean the dust on the sensor or remove the banknotes and then restart
the machine.
Code
Description
P01
The upper left IR sensor is not working properly.
P02
The upper right IR sensor is not working properly.
P03
The below left IR sensor is not working properly.
P04
The below right IR sensor is not working properly.
P05
The feeding sensor is not working properly.
P06
The size sensor is not working properly.
P09
The right passing sensor is not working properly.
P10
The left passing sensor is not working properly.
E01
Length feature not (correctly) detected
E02/ E03
Magnetism feature not (correctly) detected
E04/ E05
IR feature not (correctly) detected
E06
Thickness not (correctly) detected
E07
Slant note detected
E08
Hologram feature not (correctly) detected
E09/E10/E11/E12
Paper quality not (correctly) detected
E14
Cannot judge denomination
E20
Note jammed or blocked