CSN-A1 user manual
42
If the tab position exceeds the print area,the coordinates will move to the
star position of the next line(as the data is full,print and wrap)
Example
none
Horizontal tab position setting
Name
horizontal tab position setting
Code
ASCII
:
ESC D [d]k NUL
DEC
:
27 68 [d]k 0
HEX
:
1B 44 [d]k 00
Function
Set horizontal tab position, parameter meaning as below:
d1 ... dk
:
horizontal position,in 8 as unit,null as the terminator
Parameter
range
XX58
:
1 ≤ d ≤ 46
(
d1 <d2 < …… dk
,
1 ≤ k ≤ 16
)
XX80
:
1 ≤ d ≤ 70
(
d1 < d2 < …… dk
,
1 ≤ k ≤ 16
)
Defaults
The default positioning position is the 8-character interval(Column 9 17 25...)
of the font A(12-24)
Support
model
All
Notes
Tab position as below
:
Maximum support for the setting of 16 tab position
Using this command,the setting of previous tab position will be canceled
k is for indication purpose,no transmission
When transport [d]k,and come across NULL,should be considered over
If dk less than or equal to dk-1,should be considered over,and balance
data is treated as normal data processing
TAB position could be changed by HT command
When the left margin changes, the TAB position changes simultaneously
The command setting will be valid after ESC @
、
printer reset
、
power off
Example
1B 44 04 06 08 0A 00 09 30 09 31 09 32 09 33 0D 0A