6 - MAINTENANCE
Draining the reservoir sediment
1. Release all pressure in the hydraulic reservoir. Refer
to page
6-34
.
2. Place a receptacle of a suitable capacity under the
drain plugs.
3. Remove the drain plugs from the reservoir and drain
the sediment and water accumulated at the bottom of
the reservoir.
4. After draining, install the drain plugs.
5. Add hydraulic oil if necessary. See "Filling the reser-
voir".
E703CA80
4
Replacing the pilot filter
1. Release all pressure in the hydraulic system. Refer to
page
6-34
2. Unscrew and remove the filter using a wrench.
3. Coat the seal of the new filter with a fine film of clean
oil.
4. Install the new filter. Turn the filter until the seal comes
into contact with the filter head then tighten by an extra
third of a turn by hand.
DBC389B1
5
6-38
Содержание CX235C SR
Страница 6: ......
Страница 18: ...1 GENERAL INFORMATION 1 12 ...
Страница 28: ...2 SAFETY INFORMATION 5F3B0AF4 3 See chapter Illustration of decals for the functions of decals 2 10 ...
Страница 29: ...2 SAFETY INFORMATION 825DC955_TU1 4 2 11 ...
Страница 52: ...2 SAFETY INFORMATION 2 34 ...
Страница 70: ...3 CONTROLS INSTRUMENTS System display and function control panel MUC8LU 034Z 1 MUC8LU 044Z 2 3 18 ...
Страница 141: ...4 OPERATING INSTRUCTIONS 7 Try out all the controls in a safe open area 4 13 ...
Страница 156: ...4 OPERATING INSTRUCTIONS 4 Operate the arm control to unhook the tool KKZVLU 024A 14 4 28 ...
Страница 174: ...4 OPERATING INSTRUCTIONS 4 46 ...
Страница 184: ...5 TRANSPORT OPERATIONS 5 10 ...
Страница 284: ...8 SPECIFICATIONS Working range A31DCFA4 3 See next page for the values 8 8 ...
Страница 286: ...8 SPECIFICATIONS 8 10 ...