INTRODUCTION
Engine coolant
CASE CONSTRUCTION requires the use of a fully formulated Organic Acid Technology (OAT) based coolant.
CASE
AKCELA ACTIFULL™ OT EXTENDED LIFE COOLANT
is the reference genuine product.
NOTICE:
Use of different coolant brands is not recommended.
NOTICE:
Never add Supplemental Coolant Additives (SCA) when using
CASE AKCELA ACTIFULL™ OT
EXTENDED LIFE COOLANT
.
NOTICE:
Never mix
CASE AKCELA ACTIFULL™ OT EXTENDED LIFE COOLANT
coolant with conventional
coolant. Mixing OAT based coolant with conventional coolant will reduce the effectiveness of OAT coolant.
NOTICE:
If only conventional coolant is available, a complete changeover of the fluid into the cooling system shall be
carried out. Refer to the procedure described in the Chapter 6 (Engine coolant replacement).
The engine cooling system shall always be refilled with coolant solution made by mixture of antifreeze and distilled
(deionized) water.
NOTICE:
Never refill the cooling system with only antifreeze. Never refill the cooling system with only water.
Using
CASE AKCELA ACTIFULL™ OT EXTENDED LIFE COOLANT
, a 50/50 mixture of antifreeze and distilled
(deionized) water grants proper performance of the engine cooling system in the above mentioned operating temper-
ature range of the machine.
CASE AKCELA ACTIFULL™ OT EXTENDED LIFE COOLANT
is available as:
• 50/50 PREMIXED coolant solution ready for usage.
• CONCENTRATE antifreeze to be mixed 50/50 with distilled (deionized) water.
NOTICE:
If operating in extreme winter climate, a coolant solution made by 60/40 antifreeze/distilled (deionized) water
mixture shall be used in order to grant proper performance of the engine cooling system.
NOTICE:
Never use coolant solution with more than
60 %
of antifreeze. This affects the cooling capacity of the mix-
ture.
When the coolant solution is prepared starting from the CONCENTRATE product, the antifreeze concentration in the
mixture of antifreeze and distilled (deionized) water can be determined with a refractometer designed to measure
ethylene glycol content.
If distilled (deionized) water is not available, use water for dilution with the following properties:
Property
Maximum limit
Total Solids
340 ppm
Total Hardness
340 ppm
Chloride (Cl)
340 ppm
Sulfate (SO4)
100 ppm
Acidity pH
5.5 to 9.0
NOTICE:
Never use hard water, sea water and softened sea water that has been conditioned with salt. The minerals
and salts present in potable water can cause corrosion and deposits resulting in shortened engine life.
47937811 29/02/2016
67
Содержание CX160D
Страница 7: ...47937811 29 02 2016 Find manuals at https best manuals com...
Страница 8: ...INTRODUCTION 47937811 29 02 2016 1 Find manuals at https best manuals com...
Страница 17: ...INTRODUCTION Cab CX130D CX160D CX180D SMPH15CEX5805FA 2 47937811 29 02 2016 10...
Страница 18: ...INTRODUCTION Cab CX210D CX230D CX250D CX300D SMIL14CEX2002FA 3 47937811 29 02 2016 11...
Страница 24: ...INTRODUCTION 8023766E 1 47937811 29 02 2016 17...
Страница 25: ...INTRODUCTION 97815A48 2 47937811 29 02 2016 18...
Страница 26: ...INTRODUCTION E9BCB5F5 3 47937811 29 02 2016 19...
Страница 81: ...This as a preview PDF file from best manuals com Download full PDF manual at best manuals com...