DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM
Relief valve - Pressure test
CAS1804
1.
Raise the right side panel for the equipment control
valve.
(1)
Pressure test port diagnostic coupler.
IMPORTANT: Make sure that everyone is clear of the dozer
blade prior to proceeding.
2.
Make sure the hydraulic system fluid is at operating
temperature,
52 - 79 °C (125 - 175 °F).
3.
Connect the diagnostic coupler and pressure gauge
to the test port coupler (1 ).
4.
Make sure the Parking Brakes are applied and the
directional control is in the NEUTRAL position.
5.
Start and run the engine at FULL THROTTLE.
6.
Hold the hydraulic control lever for the Lift Cylinders
in the RAISE position.
7.
Record the reading on the pressure gauge and check
that the pressure reading is within the specification,
refer to
PRIMARY HYDRAULIC POWER SYSTEM
-
General specification (A.1 0.A)
8.
If the pressure is not correct, adjust the main re
lief valve, refer to
Relief valve - Pressure setting
(A.10.A).
87728445 1 2/28/2008
A.10.A
I
20
8D02F023
1
Содержание 750L
Страница 1: ...REPAIR MANUAL 750L 850L 87728445 1 2 28 2008 ...
Страница 4: ...87728445 1 2 28 2008 Find manuals at http best manuals com search s CASE 87728445 ...
Страница 5: ...INTRODUCTION 87728445 1 2 28 2008 1 Find manuals at http best manuals com search s CASE 87728445 ...
Страница 18: ...INTRODUCTION 87728445 1 2 28 2008 14 ...
Страница 19: ...REPAIR MANUAL DISTRIBUTION SYSTEMS 750L 850L 87728445 1 2 28 2008 A ...
Страница 21: ...DISTRIBUTION SYSTEMS A PRIMARY HYDRAULIC POWER SYSTEM 10 A 750L 850L 87728445 1 2 28 2008 A 10 A 1 ...
Страница 51: ...This as a preview PDF file from best manuals com Download full PDF manual at best manuals com ...