![Case IH FARMALL 45C CVT Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/case-ih/farmall-45c-cvt/farmall-45c-cvt_service-manual_2567532047.webp)
INTRODUCTION
Farmall 40
Farmall 45
Farmall 50
COOLING SYSTEM
Type. . . . . . .
Pressurized Liquid with
Recirculating Bypass
Pressurized Liquid with
Recirculating Bypass
Pressurized Liquid with
Recirculating Bypass
Water Pump:
Type. . . . . .
Centrifugal
Centrifugal
Centrifugal
Drive. . . . . . .
V-Belt
V-Belt
Belt.
Deflection. . . . . .
10 - 15 mm
(
7/16 - 9/16 in
)
when
9 - 11 kg
(
20 - 25 lb
)
thumb pressure is applied
midway between belt
pulleys
10 - 15 mm
(
7/16 - 9/16 in
)
when
9 - 11 kg
(
20 - 25 lb
)
thumb pressure is applied
midway between belt
pulleys
10 - 15 mm
(
7/16 - 9/16 in
)
when
9 - 11 kg
(
20 - 25 lb
)
thumb pressure is applied
midway between belt
pulleys
Fan Diameter. . . .
410 mm
(
16.1 in
)
410 mm
(
16.1 in
)
410 mm
(
16.1 in
)
Number of Fan Blades.
. . . . .
6
6
6
Thermostat:
Start to Open. . . .
80 °C
(
176 °F
)
80 °C
(
176 °F
)
80 °C
(
176 °F
)
Fully Open. . . .
95 °C
(
203 °F
)
95 °C
(
203 °F
)
95 °C
(
203 °F
)
Radiator Cap. . . .
0.9 bar
(
13 psi
)
0.9 bar
(
13 psi
)
0.9 bar
(
13 psi
)
Antifreeze. . . . . . .
Ethylene Glycol
Ethylene Glycol
Ethylene Glycol
47851945 03/02/2016