What to Expect with Your Installation

Know your wiring

If you are unfamiliar 
with wiring, use a 

qualified electrician.

You may need a 

friend to help you.

Check box to see 

fan weight

Assess location

30 inches

from blade tip to 
nearest wall or 
obstruction

7 feet

From bottom 

edge of blade 

to the floor

Select a downrod length

Assess ceiling angle

Ceilings that are more 
than 34° will require an 

angled mounting kit. 
See page 3 for details.

Must be able to 

secure the fan to 

building structure or 

fan-rated outlet box

1

2

3

Standard Downrod

for ceilings 8-10 feet high

Shorter Downrod

for fans installed close to ceiling

Longer Downrod

for ceilings 10 feet or higher

w.1 - To reduce the risk of fire, electrical shock, or personal 

injury, mount fan directly from building structure and/or an 

outlet box marked acceptable for fan support of 70 lbs (31.8 kg) 
and use the mounting screws provided with the outlet box.

w.2 - To avoid possible electrical shock, before installing or 

servicing your fan, disconnect the power by turning off the 
circuit breakers to the outlet box and associated wall switch 

location. If you cannot lock the circuit breakers in the off 

position, securely fasten a prominent warning device, such as a 

tag, to the service panel.

w.3 - To reduce the risk of fire, electrical shock, or motor damage, 
use only Casablanca Solid State Speed Controls.

w.4 - To reduce the risk of personal injury, do not bend the blade 

brackets when installing the blade brackets, balancing the blades, 

or cleaning the fan. Do not insert foreign objects in between 
rotating fan blades.

c.1 - All wiring 

must be in accordance with national and local 

electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring, 
use a qualified electrician. 

c.2 - Use only Casablanca replacement parts.

This equipment has been tested and found to comply with the 
limits for a Class B digital device, pursuant to part 15 of the FCC 
Rules. These limits are to provide reasonable protection against 
harmful interference in a residential installation. This equipment 
generates, uses and can radiate radio frequency energy and if not 
installed and used in accordance with the instructions may cause 
harmful interference to radio communications.

Read and Save These Instructions

This product conforms to UL Standard 507.

WARNINGS

CAUTIONS

2

M8539-01 • 01/12/16 • © 2016 Casablanca Fan Company

2

Содержание M8539-01

Страница 1: ...o supply you with the best ceiling fan available anywhere in the world To register your fan please visit www CasablancaFanCo com register Save your receipt for proof of purchase PA G E 5 PA G E 19 30...

Страница 2: ...y turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as...

Страница 3: ...888 227 2178 3 M8539 01 01 12 16 2016 Casablanca Fan Company Tools Needed Ladder Power Drill optional 9 64 Drill Bit optional Screwdrivers Pliers Wire Strippers If mounting to a support structure you...

Страница 4: ...have a flat ceiling Hang your fan by a standard downrod included Ceiling Options Support Structure Ceiling Outlet Box required Angled Mounting Style Standard Mounting Style Support Structure Ceiling...

Страница 5: ...cal Support at 1 888 227 2178 Make sure all four bumpers are still attached Use wood screws included when securing to support structure with approved electrical outlet box Drill 9 64 pilot holes in su...

Страница 6: ...er Shorter Downrod for fans installed close to ceiling Standard Downrod for ceilings 8 10 high For Standard Mount For Low Profile For Standard Mount skip to next page If you need a different downrod l...

Страница 7: ...the downrod can be inserted Hand tighten the downrod at least 4 5 full turns until it stops The wires can be cut but leave at least 8 extending from the top of the downrod 8 3 8 Tighten the setscrew w...

Страница 8: ...ontinued Put the wires and downrod through the canopy Let the canopy sit loosely on top of the fan DO NOT PICK THE FAN UP BY THE CANOPY OR WIRES Place the downrod ball into the slot in the ceiling bra...

Страница 9: ...connector from the hardware bag Connect the 3 grounding wires green green yellow stripe or bare copper coming from the ceiling downrod and ceiling bracket Note To connect the wires hold the bare meta...

Страница 10: ...ire from the ceiling to the black wire from the receiver Connect the white grounded wire from the ceiling to both the white wire from the receiver and the white wire from the fan FROM RECEIVER black b...

Страница 11: ...y place so that the screw holes are aligned Position the canopy so that when lifted into place the canopy fits into the hanging bracket as shown Insert the two canopy screws found in the hardware bag...

Страница 12: ...attach the blades to the motor with screws found in the hardware bag then securely tighten after all three screws are attached Note Guide posts are present on the blade to help align the blade with th...

Страница 13: ...alfway into the mounting plate on the bottom of the motor housing It does not matter which two screw holes you choose Insert the third upper switch housing screw found in the hardware bag into place a...

Страница 14: ...igned with the sticker on the upper switch housing Wrap the keyhole slots around the screws and twist the lower light kit clockwise Locate the red sticker on the upper switch housing Screw two switch...

Страница 15: ...o they line up with the tabs on the inside rim of the upper switch housing Carefully lift the globe then rotate clockwise until it is held tightly in place by the tabs Notch Tab Insert the third upper...

Страница 16: ...side up Replace with a CR2032 battery when necessary See next page for fan operation instructions CONGRATULATIONS YOU RE DONE The remote transmitter is already paired to the receiver and ready to use...

Страница 17: ...reverse switch to the opposite position Reverse Switch The up arrow and down arrow buttons control the lights on the fan Quickly press and release the up or down arrow to turn the lights off and on Ho...

Страница 18: ...s will flash for visual confirmation The lights will stay on 50 brightness for 15 seconds and then begin to dim After a total of 30 seconds the lights will be completely off The Safe Exit Program give...

Страница 19: ...are cracked If so replace all of the blades Remote does not work Make sure the battery is installed correctly Install a new battery If the remote still does not work you may need to pair your remote T...

Страница 20: ...e fans operated by a single remote control you must pair the transmitter to each additional receiver The receiver that shipped with your fan is already paired to the transmitter Note To prevent faulty...

Отзывы: