background image

 

 

22 

2.2.2 Print Report 

 

Operation 

Key 

(e.g) 

Display 

Remark 

Weight 

Unit 

Total 

MENU 

[MENU] 



Enter Menu 

Print 

Menu 

[VOID/

[*] 







Enter Print Menu 

Select   

report 

menu 

[VOID/

[*] 










Select items 

1. 

PLU 

2. 

Tax 

3. 

Hourly 

4. 

Weekly 

5. 

Monthly 

Print 

report 

[*] 

[VOID/











Print Report : yes 

[*] 

 













Print item report 
completely 
Move back to Print menu 

 
 
2.2.3 Print Total Report 
 

Operation 

Key 

(e.g) 

Display 

Remark 

Weight 

Unit 

Total 

MENU 

[MENU] 



Enter Menu 

Print 

Menu 

[VOID/

[*] 







Enter Print Menu 

Select   

report 

menu 

[VOID/

[VOID/

[*] 














Print total report list   

Print total 

report 

[*] 





Move back to Print menu 

 
Parameter:  Total  Report

 

같이

 

출력되는

  Report

 

있는

 

경우

 

Clear

 

 

같이

 

클리어

 

된다

 

Содержание Retail PR-T Series

Страница 1: ...1...

Страница 2: ...W 5 DISPLAYAND KEYBOARD 6 REMOVE THE SCREW 9 COLUMN INSTALLATION 9 OPERATION Chapter 1 Basic Operation 10 Chapter 2 PLU Saving Calling up 13 Chapter 3 User s Set up Mode 15 Chapter 4 Sales transaction...

Страница 3: ...3 PRECAUTIONS...

Страница 4: ...4 PRECAUTIONS...

Страница 5: ...elp you with the proper operation and care of your new PR T Please review the PR T manual before you use the scale and keep it handy for future reference The Pb battery of product may not be fully cha...

Страница 6: ...6 It is recommended to tear off the ticket left to right...

Страница 7: ...7 OVERALL VIEW...

Страница 8: ...8 POLE TYPE INSTALLATIONS Insert the post pipe into a post bracket Insert and fasten the display assembly screws...

Страница 9: ...9 DISPLAY Front Rear...

Страница 10: ...on Display SYMBOLS DESCRIPTION Stable Indicator To adjust the weight to zero Tare on In the subtotal mode Discount price To adjust the weight to zero AC Power On Low battery warning when it is below...

Страница 11: ...r tare value To go to program mode To call up a PLU with numeric key To input non weighed item SHIFT To select alternate key functions To show subtotal total payment sum Direct PLU keys PLUs 1 30 mayb...

Страница 12: ...12 REMOVE THE SCREW Remove the crew NOTICE Make sure to remove the screw before use at the first time COLUMN INSTALLATION Column Installation...

Страница 13: ...13...

Страница 14: ...rt DeleteReport TotalReport MonthlyReport WeeklyReport HourlyReport AllReport Scale Settings DATE TIME UsePLUtare Useinventory Suspend Definespeedkey Set Reset Printer Set Header Footer Message Settin...

Страница 15: ...ht By Count 3 Unit Price This value can be from 1 to 999999 4 Item Code Item Code can be from 0 to 99999 optional 5 Tax No Enter tax index number This value can be from 0 to9 optional 6 Tare No Enter...

Страница 16: ...unit price Critical Item Must be not 0 PLU Itemcode 2 0 3 4 Input Item code for Barcode optional PLU NAME A PLU01 P PLU16 P PLU16 L PLU12 E PLU05 When create a PLU PLU name is filled with space 32 Ent...

Страница 17: ...17...

Страница 18: ...ght Unit Total MENU MENU Enter Menu Sale Menu Enter Sale Menu Inventory menu VOID Enter Inventory menu Input PLU No 1 Enter PLU No Edit Inventory value 5 0 0 0 Input inventory value Tax Menu Move back...

Страница 19: ...0 VOID Input Tax value Press VOID ADD key to change tax type I include E excluse Tax Menu Move back to SALE menu 2 1 4 Create PLU Tare index SAMPLE Create Edit Tare Operation Operation Key e g Displa...

Страница 20: ...0 Input start PLU number to delete PLU list Delete item list No 2 2 Input end PLU number to delete PLU list Delete item Move back to Sale menu 2 2 List Report 2 2 1 Print list Operation Key e g Displa...

Страница 21: ...21 Parameter USE PLU TARE NO...

Страница 22: ...Hourly 4 Weekly 5 Monthly Print report VOID Print Report yes Print item report completely Move back to Print menu 2 2 3 Print Total Report Operation Key e g Display Remark Weight Unit Total MENU MENU...

Страница 23: ...HH MM SS Press key to accept Set date time Move back to set menu 2 3 2 Use PLU Tare Operation Key e g Display Remark Weight Unit Total MENU Enter Menu Set Menu VOID VOID Enter Set Menu enter Use Tare...

Страница 24: ...entory Set Use inventory Move back to set menu Use Inventory When this Settings set off can t Use inventory in PLU programming 2 3 4 Suspend display Operation Key e g Display Remark Weight Unit Total...

Страница 25: ...Select header 1 header 1 2 header 2 3 header 3 4 footer Set header 6 7 VOID 6 5 VOID 8 3 Set header When create a header that filled with space 32 Enter the header by referring ASCII codes Press VOID...

Страница 26: ...ader 1 header 1 2 header 2 3 header 3 4 footer Set header 6 7 VOID 6 5 VOID 8 3 Set header When create a header that filled with space 32 Enter the header by referring ASCII codes Press VOID key to mo...

Страница 27: ...t image completely display done with beep Move back to printer setting menu Note Use image print off 2 4 4 Image Test Operation Key e g Display Remark Weight Unit Total MENU MENU Enter Menu Printer Se...

Страница 28: ...et line feed completely display done with beep Move back to printer setting menu 2 4 6 Print PLU details after prgramming Operation Key e g Display Remark Weight Unit Total MENU MENU Enter Menu Printe...

Страница 29: ...o accept Set print bill completely display done with beep Move back to printer setting menu 2 4 8 Print intensity Operation Key e g Display Remark Weight Unit Total MENU MENU Enter Menu Printer Set Me...

Страница 30: ...nter Set Menu VOID VOID VOID Enter Printer Set Menu Printer Set Menu VOID VOID VOID VOID VOID VOID Enter print bill Menu default on Off don t print bill Set line feed VOID Set print intensity Press ke...

Страница 31: ...the weight on the tray CAL ERROR When turning on the scale this message may be displayed with continuous beep and it is automatically turned off Please call your CAS dealer INIT ERROR Please remove th...

Страница 32: ...50km or more PLU MEMORY CAPACITY 30 Direct PLUs 270 Indirect PLUs 2 Special PLUs POWER AC 230V 50 60Hz OPERATINGTEMPERATURE 0 40 EXTERNALUTILITIES Default RS232C POWER CONSUMPTION Maximum 35W BATTERY...

Страница 33: ...33 MEMO...

Страница 34: ...34 MEMO...

Страница 35: ...35...

Отзывы: