background image

 

15

 

Chapter 3. User’s Set-up Mode 

 

This section explains how to set up the following functions. 

 

Functions 

Options 

Remarks

a. Auto power-off 

NO / 10 / 30 / 60 

 

b. Suspend Mode 

OFF / 20 / 40 / 60 

 

 

 

  To get into “User’s Set-up 

Mode”, hold 

ZERO

 key and press 

ON/OFF

 key, while the scale is 

 

 Press 

ZERO

 key to save current option and move to next function setting mode.   

 Press 

TARE

 key to move to other next option.   

 
a. Auto power-off 

 

This section explains how to set backlight on & off function and automatic off function. 

Options 

Description 

Remarks 

NO 

  No auto power-off. 

 

10 (minutes) 

  Auto power-off in 10 minutes when no use. 

 

30 (minutes) 

  Auto power-off in 30 minutes when no use. 

 

60 (minutes) 

  Auto power-off in 60 minutes when no use. 

 

 

 

 Select an option you wish to have 

by using 

TARE

 key. Ex) 30 

(minutes).  

 

 
 

Содержание PR Plus-B

Страница 1: ...1 표지 ...

Страница 2: ...EW 5 DISPLAYAND KEY BOARD 6 REMOVE THE SCREW 9 COLUMN INSTALLATION 9 OPERATION Chapter 1 Basic Operation 10 Chapter 2 PLU Saving Calling up 13 Chapter 3 User s Set up Mode 15 Chapter 4 Sales transaction 17 TECHNICALPARAMETER 19 ERROR MESSAGE 19 ...

Страница 3: ...3 PRECAUTIONS ...

Страница 4: ... PRECAUTIONS 4 ...

Страница 5: ...ntrol and with outstanding performance Your special departments can enjoy these high quality reliable CAS products We believe that your needs will be satisfied and you will have proper reliability This manual will help you with proper operation and care of the PR PLUS Please keep it handy for future reference OVERALL VIEW ...

Страница 6: ... 6 DISPLAY AND KEY BOARD PRPLUS B Front display PRPLUS B Rear display PRPLUS P Front cover ...

Страница 7: ... PRPLUS P display key 7 ...

Страница 8: ...he scale Used to clear all the numeric price display Used to clear sum total price Used to clear all the daily total prices Used to correct the zero point To set or clear tare value PLU save key Display battery voltage push more than 2second Used to enter the decimal point when price is entered 8 ...

Страница 9: ...9 REMOVE THE SCREW Remove the crew NOTICE Make sure to remove the screw before use at the first time COLUMN INSTALLATION Column Column Support Screw Figure one Figure two Column Installation ...

Страница 10: ... 10 OPERATION Chapter 1 Basic Operation a To turn on off the scale Press the ON OFF key to turn on Press the ON OFF key for a few seconds to turn off b Zero function Press ZERO key to set Zero ...

Страница 11: ... you weigh an item with container and measure only the weight of item One time tare Place a container on the platter EX 200g of tare Press TARE key to set zero point EX 200g of tare Successive tare Place another container on the platter EX 100g of tare Press TARE key to set zero point ...

Страница 12: ...ve TARE funtion press TARE Key again after removing the container from the paltter Automatic tare clearing function may not be applied to all of PR series d Display battery voltage 1 Press Press key to check battery voltage left push more than 2second It shows percentage of full voltage Please recharge under the 10 ...

Страница 13: ...ectionexplainshowtosaveunitpriceinPLU Number of PLU Range Remarks PLU NAME 4 1 4 Press number key to input unit price you wish to have EX 1 99 Press key for a few seconds to enter the PLU s state can be pre establish Press PLU key M1 M4 to input a direct PLU address Ex ...

Страница 14: ...ppropriate ASCII codes to save the PLU name Ex APPLE is 4 1 C 5 0 C 5 0 C 4 C alphabet C 4 5 C Press TARE key to exit to normal weighing mode or C key up to maximum 8th byte Then automatically exit to normal weighing mode c Calling up PLU Press M1 M4 key to call up PLU e g Press M1 key Press C key to clear and return to the normal weighing mode 4 ...

Страница 15: ... save current option and move to next function setting mode Press TARE key to move to other next option a Auto power off This section explains how to set backlight on off function and automatic off function Options Description Remarks NO No auto power off 10 minutes Auto power off in 10 minutes when no use 30 minutes Auto power off in 30 minutes when no use 60 minutes Auto power off in 60 minutes ...

Страница 16: ...s Description Remarks OFF No suspend mode 20 seconds Suspend mode in 20 seconds when no use 40 seconds Suspend mode in 40 seconds when no use 60 seconds Suspend mode in 60 seconds when no use PressZEROkeytomovenextfunction setting suspendmode PressTAREkeytoselectatimetosuspend mode ...

Страница 17: ...g up PLU a Input the unit price through the numeric key This section explains how to input the unit price through the numeric key and complete the sales transaction Place an item on the platter and press appropriate numeric keys to input unit price EX 1 99 for unit price Remove the item from the platter 7 ...

Страница 18: ... 1 b Input the unit price through calling up PLU Press M1 M4 key can call up the PLU EX M1 Place an item on the platter Remove an item on the platter 8 ...

Страница 19: ...V 50 60Hz PB4V4Ah POWERCONSUMPTION APPROX 4W PLATTER SIZE mm 322W x212 D ERROR MESSAGES Table Error Message Error Message onDisplay Description Solution Err0 The Err0 occurswhenscaleisnotstable Removeunstablefacts Err1 The Err 1 occurs when a current zero point has shiftedfromthelastspancalibration PleasecallyourCASdealer Err3 The Err3 isanoverloaderror Pleaseremovetheweight Err4 The Err4 isleakag...

Страница 20: ... 20 MEMO ...

Страница 21: ...21 MEMO ...

Страница 22: ... 22 ...

Отзывы: