background image

 

3

 

CONTENTS 

 

Precautions ................................................................. 4 

Display and Keyboard.............................................. 7 

Enter to features ........................................................ 8 

Normal turn off process ........................................... 9 

    1. Switch off ..............................................................................9 

      2. Display of switch off.............................................................9

 

Operations .................................................................. 9 

 1. Zero..........................................................................................9 

   2. Tare ..........................................................................................9 
   3. Number 0~9 and digit unit...................................................9 
   4. Delete .....................................................................................10 
   5. SMPL sampling ...................................................................10 
   6. UWS single weight entering...............................................10 
   7. Weight/Quantity accumulation.........................................10 
   8. Accumulative display..........................................................11 
   9. Accumulative clear..............................................................11 
   10. Print.....................................................................................11 
   11. Set up Hi limit ....................................................................11 
   12. Set up Low limit.................................................................12 
   13. Check function...................................................................12 
   14. Features Setting .................................................................13 
   15. RS232 Setting.....................................................................14 
   16. Check weighing warning setting.....................................15

 

Internal count value display .................................. 16 

Error message .......................................................... 16 

Specifications............................................................ 17 

 

 

Содержание PR-C series

Страница 1: ...3...

Страница 2: ...digit unit 9 4 Delete 10 5 SMPLsampling 10 6 UWS single weight entering 10 7 Weight Quantity accumulation 10 8 Accumulative display 11 9 Accumulative clear 11 10 Print 11 11 Set up Hi limit 11 12 Set...

Страница 3: ...4 Precautions...

Страница 4: ...5 Precautions...

Страница 5: ...te a power supply for the balance When a power supply for the balance is turned on and off a Power supply key shall be used and nothing shall be allowed to be placed on a platter This balance has a ch...

Страница 6: ...It displays an accumulated quantity or a measured quantity up to 6 digits 2 Display symbols Symbol Detailed content Net weight mode Zero point display Being in a stable condition Battery being in a ch...

Страница 7: ...nternal setting internal setting press Go to RS232 setting Under internal setting internal setting press Go to checking setting Turn on Zero Turn on Tare Turn on Enter delete Accumulative delete Turn...

Страница 8: ...00ms during each hour COUNT VerX are shown continuously Ex COUNT 30kg Ver0 Operating functions explanation 1 Zero Step Operation 1 Click zero point At a zero point the total weight is displayed as O 2...

Страница 9: ...tinuously displayed in the display window 6 UWS single weight entering Step Operation 1 a Upon inputting values of weight unitweight 0 will be continuously displayed in the display window b Upon input...

Страница 10: ...continuously displayed in the display window it will return to the weight setting a second later 10 Print Step Operation 1 Upon outputting using RS232 printing will be executed by RE232 method by cli...

Страница 11: ...on In the display window originalvalue SEtLo 0 will be continuously displayed b When keys are clicked originalvalue SEtHi 0 will be continuously displayed in the screen c After inputting values click...

Страница 12: ...ontinuously displayed in the display window 4 Check while clicking the key and return to the weight measurement Example 1 a b c d e 02210 a Backlight setting Function available only in LCD 0 Automatic...

Страница 13: ...ntering value RSSET will be continuously displayed in the display window 4 Check after clicking the key and return to the weight measurement Example 1 a b c d e 11111 a Baud rate setting 0 4800 1 9600...

Страница 14: ...ll be continuously displayed in the display window 4 Check after clicking the key and return to the weight setting Example 1 a b c d e 00010 a Set up check alarm type 0 Weight 1 Quantity b Set up stab...

Страница 15: ...3 Upon clicking the the screen will return to the weight setting again Error message Error code Cause Battery charging required B Err Emergency battery charging required oL Checking required to see if...

Страница 16: ...5g 1g External Resolution 1 30 000 Internal Resolution 1 600 000 Display Type LED Weight Units Kg g lb oz Operating temperature 0 40 Power AC 220 240 50 60Hz Pb Battery 6V 4Ah Battery life 100hrs Dime...

Страница 17: ...18 MEMO...

Страница 18: ...19 4...

Отзывы: