Press and hold button 6: Turn on relay 6 (connect B and C, disconnect A and B) 
Release button 6: Turn off relay 6 (disconnect B and C, connect A and B) 
 
3) Learning Latched control mode: When the receiver is in the status of LEARNING, press button 3 of the remote control. 
Control mode Latched (Channel 1~8): Press -> On, other relays Off; Press other button -> Off. 
Press button 1: Turn on relay 1 (connect B and C, disconnect A and B) 

Turn off other relay (disconnect B and C, connect A and B) 

… 
Press button 6: Turn on relay 6 (connect B and C, disconnect A and B) 

Turn off other relay (disconnect B and C, connect A and B) 

 
4) Learning Momentary (Channel 1~3) + Toggle (Channel 4~6) control mode: When the receiver is in the status of LEARNING, press button 4 of 
the remote control. 
 
5) Learning Momentary (Channel 1~3) + Latched (Channel 4~6) control mode: When the receiver is in the status of LEARNING, press button 5 of 
the remote control. 
 
6) Learning Toggle control mode (Channel 1~4) + All On / Off (Channel 5/6): When the receiver is in the status of LEARNING, press button 6 of 
the remote control.   
Press button 5: Turn on all 6 relays 
Press button 6: Turn off all 6 relays 
 
We have learned remote control to the receiver. If you don’t want the receiver to work with the remote control, you can delete all codes of remote 
controls, which are stored in the receiver. 
Operation: Press and hold the button of receiver until signal LED flashes slowly; release the button, LED keeps slow flash. That means all stored 
codes have been deleted successfully. 
 
Learning the button of remote control: 
1) Press the button of receiver; signal LED on the receiver keeps shining. The receiver enters into status of LEARNING.   
2) Press any one button on remote control. If signal LED flashes quickly 15 times and turns off, it means learning is successful.   
3) When receiver is in the status of LEARNING, press again the button of receiver, signal LED turns off, learning process will be discontinued. 
4) The receiver can learn several remote controls with different codes. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Application Circuit 

 

Signal LED 

A, B=Normally Closed; B, C=Normally Open.

 

Lamp 1 

Lamp 3 

Lamp 5 

Lamp 2 

Lamp 4 

DC 0~28V / AC 110~240V 

Lamp 6 

Power Supply 

Button 

 

Power LED 

Relay 1 

Relay 3 

Relay 5 

Relay 2 

Relay 4 

Relay 6 

IC 

A

nt
e

nn
a

 

 

R

m

odu

le

 

 