CaryMart 0020524 Скачать руководство пользователя страница 2

SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT CO.,LTD 

Http://w ww.carymart.com      E-Mail: [email protected] 

another AC or DC device through a device that has a normally open contact output. 

Working process: 
1. 

Connect a device A w hich w ith normally open output to the tw o input lines of the transmitter; connect the other device B to the receiver.

 

2. 

When the transmitter's tw o input lines are connected, it automatically emits an "ON" w ireless signal, w hich is equivalent to  the function of the 

button "ON" on the transmitter. When the receiver receives the w ireless signal, it w ill activate its relay to turn on the connected device B. 
3. When the transmitter's tw o input lines are disconnected, it automatically emits an "OFF" w ireless signal, w hich is equivalent  to the function of the 
button "OFF" on the transmitter. When the receiver receives the w ireless signal, it w ill deactivate its relay to turn off the connected device B.

 

 
Matching Transm itters:

 

The receiver can w ork w ith different transmitters, such as model C-2 (100M), CWB-2 (50M, w aterproof), CP-2 (500M), or CB-2 (1000M) etc.

  

 

Working Range: 

Super long range, w ith a transmitter (such asCB-2N) to form a complete set, the maximum w orking distance can reach 2000M in an open ground.   
The maximum w orking distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it w ill 
be hindered by trees, w alls or other constructions, and w ill be interfered by other w ireless signals. Therefore, the actual distance may not reach this 
maximum w orking distance.

 

 

Usage (with the transmitter like CB-2N): 

The receiver can be used to control both DC 0~28V and AC 110~240V equipments. 
Notice: The receiver is relay output, not DC/AC pow er output. Initial state of relay output terminals: Terminals B and C are Normally Open; Terminals 
A and C are Normally Closed.  
 

Wiring: 

If you w ant to control a DC 12V lamp, do as follow ing: 
1) Connect the positive pole of DC 

pow er supply to terminal “L / +”, and connect the negative pole of DC pow er supply to terminal “N / -”. 

2) Connect terminal B to the positive pole of DC pow er supply, connect terminal C to the positive pole of DC lamp, and connect the negative pole of 
DC lamp to the negative pole of DC pow er supply. 
 
If you w ant to control an AC 220V lamp, do as follow ing: 
1) Connect the positive pole of DC 

pow er supply to terminal “L / +”, and connect the negative pole of DC pow er supply to terminal “N / -”. 

2) Connect terminal B to the live w ire of AC pow er supply, connect terminal  C to one side of AC lamp, and connect another side of AC lamp to the 
neutral w ire of AC pow er supply. 
 

Operation: 

The receiver paired to this transmitter can be turned on / off by pressing buttons on the transmitter, connecting the red w ir e and black w ire of the 
transmitter or connecting the red w ire and black w ire to a sw itch/sensor. 
 

Controlling the receiver by pressing buttons on the transmitter: 

Press button A on the transmitter -> On, the device controlled by the receiver starts to w ork; 
Press button B on the transmitter -> Off, the device controlled by the receiver stops w orking. 
 

Controlling the receiver by connecting red wire and black wire of the transmitter: 

When connecting the red w ire and black w ire of this transmitter, the transmitter w ill be triggered and then it w ill send an RF signal of "ON" to turn on 
the receiver, the device controlled by the receiver w ill starts to w ork. 
When disconnecting the red w ire and black w ire of this transmitter, the transmitter w ill be triggered and then it w ill send an RF signal of "OFF" to turn 
off the receiver, the device controlled by the receiver w ill stops w orking. 
 

The transm itter can also be triggered by connecting the red w ire and black w ire to a switch or a sensor, but the switch or se nsor must be 
norm ally open (NO). 

 

Wired control term inals: 

The receiver has w ired control terminals, you can connect external devices, sensors, limit sw itches or manual sw itches to trigger the receiver. 
 
1) By low  level signal: 

You can connect external devices (w ith low  level output signal) to trigger the receiver. 

When the external device outputs low  level signal to terminal 1 (Signal -) and terminal 2 (), the receiver turns on the relay. (Connect B and C, 

disconnect A and C), the device controlled by the receiver w ill starts to w ork. 

When t

he 

external 

device 

stops

 to output

 signal, the receiver turns off the relay. (Disconnect B and C, connect A and C) , the device controlled by the 

receiver w ill stops w orking.

 

 

2) By NO/NC contact: 
You can connect manual sw itches (w ith NO/NC contact) to trigger the receiver. 

When connect terminals 1 and 2, the receiver turns on the relay. (Connect B and C, disconnect A and C) , the device controlled by the receiver w ill 

starts to w ork. 

And w hen disconnect terminals 1 and 2, the receiver turns off the relay. (Disconnect B and C, connect A and C), the device controlled by the receiver 

w ill stops w orking.

 

 

How to pair the transmitter to the receiver: 

Содержание 0020524

Страница 1: ...ously You can use two or more units in the same place Receiver Parameters Model No S1PU DC06 ANT3 S1PU DC09 ANT3 S1PU DC12 ANT3 S1PU DC24 ANT3 Pow er Supply Operating Voltage DC6V S1PU DC06 ANT3 DC9V 1V S1PU DC09 ANT3 DC12V 1V S1PU DC12 ANT3 DC24V 1V S1PU DC24 ANT3 Output Relay output Normally open and normally closed Working Voltage Range of Relay AC110 240V or DC0 28V Wire range for the terminal...

Страница 2: ...onnect the negative pole of DC pow er supply to terminal N 2 Connect terminal B to the live w ire of AC pow er supply connect terminal C to one side of AC lamp and connect another side of AC lamp to the neutralw ire of AC power supply Operation The receiver paired to this transmitter can be turned on off by pressing buttons on the transmitter connecting the red wire and black wire of the transmitt...

Страница 3: ... status of LEARNING press again the button of receiver signal LED turns off learning process will be discontinued 4 The receiver can learn several remote controls with different codes Delete all transmitters We have learned remote control to the receiver If you don t want the receiver to work with the remote control you can delete all codes of remote controls which are stored in the receiver Opera...

Страница 4: ...D Signal LED Learning Button External Device RF module Antenna Signal Signal L N C B A _ DC Power Supply AC Power Supply Control AC Lamp Relay CN2 CN1 Status LED Power LED Signal LED Learning Button External Device RF module Antenna Signal Signal L N C B A Live wire Neutral wire AC Lamp DC Lamp 2 1 1 2 B C Normally Open A C Normally Closed B C Normally Open A C Normally Closed ...

Отзывы: