another AC or DC device through a device that has a normally open contact output.
Working process:
1.
Connect a device A w hich w ith normally open output to the tw o input lines of the transmitter; connect the other device B to the receiver.
2.
When the transmitter's tw o input lines are connected, it automatically emits an "ON" w ireless signal, w hich is equivalent to the function of the
button "ON" on the transmitter. When the receiver receives the w ireless signal, it w ill activate its relay to turn on the connected device B.
3. When the transmitter's tw o input lines are disconnected, it automatically emits an "OFF" w ireless signal, w hich is equivalent to the function of the
button "OFF" on the transmitter. When the receiver receives the w ireless signal, it w ill deactivate its relay to turn off the connected device B.
Matching Transm itters:
The receiver can w ork w ith different transmitters, such as model C-2 (100M), CWB-2 (50M, w aterproof), CP-2 (500M), or CB-2 (1000M) etc.
Working Range:
Super long range, w ith a transmitter (such asCB-2N) to form a complete set, the maximum w orking distance can reach 2000M in an open ground.
The maximum w orking distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it w ill
be hindered by trees, w alls or other constructions, and w ill be interfered by other w ireless signals. Therefore, the actual distance may not reach this
maximum w orking distance.
Usage (with the transmitter like CB-2N):
The receiver can be used to control both DC 0~28V and AC 110~240V equipments.
Notice: The receiver is relay output, not DC/AC pow er output. Initial state of relay output terminals: Terminals B and C are Normally Open; Terminals
A and C are Normally Closed.
Wiring:
If you w ant to control a DC 12V lamp, do as follow ing:
1) Connect the positive pole of DC
pow er supply to terminal “L / +”, and connect the negative pole of DC pow er supply to terminal “N / -”.
2) Connect terminal B to the positive pole of DC pow er supply, connect terminal C to the positive pole of DC lamp, and connect the negative pole of
DC lamp to the negative pole of DC pow er supply.
If you w ant to control an AC 220V lamp, do as follow ing:
1) Connect the positive pole of DC
pow er supply to terminal “L / +”, and connect the negative pole of DC pow er supply to terminal “N / -”.
2) Connect terminal B to the live w ire of AC pow er supply, connect terminal C to one side of AC lamp, and connect another side of AC lamp to the
neutral w ire of AC pow er supply.
Operation:
The receiver paired to this transmitter can be turned on / off by pressing buttons on the transmitter, connecting the red w ir e and black w ire of the
transmitter or connecting the red w ire and black w ire to a sw itch/sensor.
Controlling the receiver by pressing buttons on the transmitter:
Press button A on the transmitter -> On, the device controlled by the receiver starts to w ork;
Press button B on the transmitter -> Off, the device controlled by the receiver stops w orking.
Controlling the receiver by connecting red wire and black wire of the transmitter:
When connecting the red w ire and black w ire of this transmitter, the transmitter w ill be triggered and then it w ill send an RF signal of "ON" to turn on
the receiver, the device controlled by the receiver w ill starts to w ork.
When disconnecting the red w ire and black w ire of this transmitter, the transmitter w ill be triggered and then it w ill send an RF signal of "OFF" to turn
off the receiver, the device controlled by the receiver w ill stops w orking.
The transm itter can also be triggered by connecting the red w ire and black w ire to a switch or a sensor, but the switch or se nsor must be
norm ally open (NO).
Wired control term inals:
The receiver has w ired control terminals, you can connect external devices, sensors, limit sw itches or manual sw itches to trigger the receiver.
1) By low level signal:
You can connect external devices (w ith low level output signal) to trigger the receiver.
When the external device outputs low level signal to terminal 1 (Signal -) and terminal 2 (), the receiver turns on the relay. (Connect B and C,
disconnect A and C), the device controlled by the receiver w ill starts to w ork.
When t
he
external
device
stops
to output
signal, the receiver turns off the relay. (Disconnect B and C, connect A and C) , the device controlled by the
receiver w ill stops w orking.
2) By NO/NC contact:
You can connect manual sw itches (w ith NO/NC contact) to trigger the receiver.
When connect terminals 1 and 2, the receiver turns on the relay. (Connect B and C, disconnect A and C) , the device controlled by the receiver w ill
starts to w ork.
And w hen disconnect terminals 1 and 2, the receiver turns off the relay. (Disconnect B and C, connect A and C), the device controlled by the receiver
w ill stops w orking.
How to pair the transmitter to the receiver: