CaryMart 0020301 Скачать руководство пользователя страница 2

SHENZHEN FLYING INDUSTRY DEVELOPMENT CO.,LTD

 

Http://www.carymart.com    E-Mail: [email protected]

 

Usage (with the transmitter C-4):

 

The receiver can be used to control both DC 0~28V and AC 110~240V equipments.

 

Notice:  The  receiver  is  dry  relay  output,  not  DC/AC  power  output.  Initial  state  of  relay  output  terminals:  Terminals  B  and  C  are  Normally  Open; 
Terminals A and C are Normally Closed.

 

 

Wiring:

 

1) If you want to control a DC 12V lamp, do as following:

 

1.1 Connect the positive pole of DC power supply to terminal “L/+” of INPUT, and connect the negative pole of DC power supply to terminal 

“N/−”

 of 

INPUT.

 

1.2 Connect terminal B to the positive pole of DC power supply, connect terminal C to the positive pole of DC lamp, and connect the negative pole of 
DC lamp to the negative pole of DC power supply.

 

 

2) If you want to control an AC 120V or AC 220V lamp, do as following:

 

2.1 Connect the positive pole of DC power supply to terminal “L/+” of INPUT, and connect the negative pole of DC power supply to terminal 

“N/−”

 of 

INPUT.

 

2.2 Connect terminal B to the live wire of AC power supply, connect terminal C to one side of AC lamp, and connect another side of AC lamp to the 
neutral wire of AC power supply.

 

 

Setting different control modes:

 

We have set the receiver as Self-locking control mode before delivery. If you want to use other control modes, do as following operation:

 

 

1) Setting Self-locking mode: Only connect Jumper-2.

 

Mode Self-locking (working with transmitter C-4): Press -> On; Press again -> Off.

 

Press button 1 of the transmitter: The relay of the receiver 1 is activated (connect the terminals B and C, disconnect the terminals A and C), and the 
lamp 1 is turned on.

 

Press button 1 of the transmitter again: The relay of the receiver 1 is deactivated (disconnect the terminals B and C, connect the terminals A and C), 
and the lamp 1 is turned off.

 

Press button 2 of the transmitter: The relay of the receiver 2 is activated (connect the terminals B and C, disconnect the terminals A and C), and the 
lamp 2 is turned on.

 

Press button 2 of the transmitter again: The relay of the receiver 2 is deactivated (disconnect the terminals B and C, connect the terminals A and C), 
and the lamp 2 is turned off.

 

Press button 3 of the transmitter: The relay of the receiver 3 is activated (connect the terminals B and C, disconnect the terminals A and C), and the 
lamp 3 is turned on.

 

Press button 3 of the transmitter again: The relay of the receiver 3 is deactivated (disconnect the terminals B and C, connect the terminals A and C), 
and the lamp 3 is turned off.

 

Press button 4 of the transmitter: The relay of the receiver 4 is activated (connect the terminals B and C, disconnect the terminals A and C), and the 
lamp 4 is turned on.

 

Press button 4 of the transmitter again: The relay of the receiver 4 is deactivated (disconnect the terminals B and C, connect the terminals A and C), 
and the lamp 4 is turned off.

 

 

2) Setting Momentary mode: Only connect Jumper-1.

 

Mode Momentary (working with transmitter C-4): Press and hold -> On; Release -> Off.

 

Press and hold button 1 of the transmitter: The relay of the receiver 1 is activated (connect the terminals B and C, disconnect the terminals A and C), 
and the lamp 1 is turned on.

 

Release button 1 of the transmitter: The relay of the receiver 1 is deactivated (disconnect the terminals B and C, connect the terminals A and C), and 
the lamp 1 is turned off.

 

Press and hold button 2 of the transmitter: The relay of the receiver 2 is activated (connect the terminals B and C, disconnect the terminals A and C), 
and the lamp 2 is turned on.

 

Release button 2 of the transmitter: The relay of the receiver 2 is deactivated (disconnect the terminals B and C, connect the terminals A and C), and 
the lamp 2 is turned off.

 

Press and hold button 3 of the transmitter: The relay of the receiver 3 is activated (connect the terminals B and C, disconnect the terminals A and C), 
and the lamp 3 is turned on.

 

Release button 3 of the transmitter: The relay of the receiver 3 is deactivated (disconnect the terminals B and C, connect the terminals A and C), and 
the lamp 3 is turned off.

 

Press and hold button 4 of the transmitter: The relay of the receiver 4 is activated (connect the terminals B and C, disconnect the terminals A and C), 
and the lamp 4 is turned on.

 

Release button 4 of the transmitter: The relay of the receiver 4 is deactivated (disconnect the terminals B and C, connect the terminals A and C), and 
the lamp 4 is turned off.

 

 

3) Setting Interlocking mode: Disconnect Jumper-1 and Jumper-2.

 

Mode Interlocking (working with transmitter C-4): Press -> On; Press another button -> Off.

 

Press button 1 of the transmitter: The relay of the receiver 1 is activated (connect the terminals B and C, disconnect the terminals A and C), and the 
lamp 1 is turned on. The relays of the receivers 2, 3, 4 are deactivated (disconnect the terminals B and C, connect the terminals A and C), and the 
lamps 2, 3, 4 are turned off.

 

Press button 2 of the transmitter: The relay of the receiver 2 is activated (connect the terminals B and C, disconnect the terminals A and C), and the 
lamp 2 is turned on. The relays of the receivers 1, 3, 4 are deactivated (disconnect the terminals B and C, connect the terminals A and C), and the 
lamps 1, 3, 4 are turned off.

 

Press button 3 of the transmitter: The relay of the receiver 3 is activated (connect the terminals B and C, disconnect the terminals A and C), and the 

Содержание 0020301

Страница 1: ... same place A 4 button transmitter controls 4 single channel receivers and each button controls a receiver Receiver Parameters Model No S1PU DC06 ANT3 S1PU DC09 ANT3 S1PU DC12 ANT3 S1PU DC24 ANT3 Power Supply Operating Voltage DC6V S1PU DC06 DC9V 1V S1PU DC09 DC12V 1V S1PU DC12 DC24V 2V S1PU DC24 Output Relay output Normally open and normally closed Working Voltage Range of Relay AC110 240V or DC0...

Страница 2: ...ay of the receiver 4 is activated connect the terminals B and C disconnect the terminals A and C and the lamp 4 is turned on Press button 4 of the transmitter again The relay of the receiver 4 is deactivated disconnect the terminals B and C connect the terminals A and C and the lamp 4 is turned off 2 Setting Momentary mode Only connect Jumper 1 Mode Momentary working with transmitter C 4 Press and...

Страница 3: ...activated disconnect the terminals B and C connect the terminals A and C and the lamp is turned off 2 By NO NC contact You can connect manual switch to terminals 1 and 2 then you can use manual switch to control the receiver When connect terminals 1 and 2 the relay is activated connect the terminals B and C disconnect the terminals A and C and the lamp is turned on When disconnect terminals 1 and ...

Страница 4: ... Signal LED Learning Button External Device RF module Antenna Signal Signal L N C B A _ DC Power Supply AC Power Supply Control AC Lamp Relay CN2 CN1 Status LED Power LED Signal LED Learning Button External Device RF module Antenna Signal Signal L N C B A Live wire Neutral wire AC Lamp DC Lamp 2 1 1 2 B C Normally Open A C Normally Closed B C Normally Open A C Normally Closed ...