![CaryMart 0020301 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/carymart/0020301/0020301_manaul_2565915002.webp)
SHENZHEN FLYING INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com E-Mail: [email protected]
Usage (with the transmitter C-4):
The receiver can be used to control both DC 0~28V and AC 110~240V equipments.
Notice: The receiver is dry relay output, not DC/AC power output. Initial state of relay output terminals: Terminals B and C are Normally Open;
Terminals A and C are Normally Closed.
Wiring:
1) If you want to control a DC 12V lamp, do as following:
1.1 Connect the positive pole of DC power supply to terminal “L/+” of INPUT, and connect the negative pole of DC power supply to terminal
“N/−”
of
INPUT.
1.2 Connect terminal B to the positive pole of DC power supply, connect terminal C to the positive pole of DC lamp, and connect the negative pole of
DC lamp to the negative pole of DC power supply.
2) If you want to control an AC 120V or AC 220V lamp, do as following:
2.1 Connect the positive pole of DC power supply to terminal “L/+” of INPUT, and connect the negative pole of DC power supply to terminal
“N/−”
of
INPUT.
2.2 Connect terminal B to the live wire of AC power supply, connect terminal C to one side of AC lamp, and connect another side of AC lamp to the
neutral wire of AC power supply.
Setting different control modes:
We have set the receiver as Self-locking control mode before delivery. If you want to use other control modes, do as following operation:
1) Setting Self-locking mode: Only connect Jumper-2.
Mode Self-locking (working with transmitter C-4): Press -> On; Press again -> Off.
Press button 1 of the transmitter: The relay of the receiver 1 is activated (connect the terminals B and C, disconnect the terminals A and C), and the
lamp 1 is turned on.
Press button 1 of the transmitter again: The relay of the receiver 1 is deactivated (disconnect the terminals B and C, connect the terminals A and C),
and the lamp 1 is turned off.
Press button 2 of the transmitter: The relay of the receiver 2 is activated (connect the terminals B and C, disconnect the terminals A and C), and the
lamp 2 is turned on.
Press button 2 of the transmitter again: The relay of the receiver 2 is deactivated (disconnect the terminals B and C, connect the terminals A and C),
and the lamp 2 is turned off.
Press button 3 of the transmitter: The relay of the receiver 3 is activated (connect the terminals B and C, disconnect the terminals A and C), and the
lamp 3 is turned on.
Press button 3 of the transmitter again: The relay of the receiver 3 is deactivated (disconnect the terminals B and C, connect the terminals A and C),
and the lamp 3 is turned off.
Press button 4 of the transmitter: The relay of the receiver 4 is activated (connect the terminals B and C, disconnect the terminals A and C), and the
lamp 4 is turned on.
Press button 4 of the transmitter again: The relay of the receiver 4 is deactivated (disconnect the terminals B and C, connect the terminals A and C),
and the lamp 4 is turned off.
2) Setting Momentary mode: Only connect Jumper-1.
Mode Momentary (working with transmitter C-4): Press and hold -> On; Release -> Off.
Press and hold button 1 of the transmitter: The relay of the receiver 1 is activated (connect the terminals B and C, disconnect the terminals A and C),
and the lamp 1 is turned on.
Release button 1 of the transmitter: The relay of the receiver 1 is deactivated (disconnect the terminals B and C, connect the terminals A and C), and
the lamp 1 is turned off.
Press and hold button 2 of the transmitter: The relay of the receiver 2 is activated (connect the terminals B and C, disconnect the terminals A and C),
and the lamp 2 is turned on.
Release button 2 of the transmitter: The relay of the receiver 2 is deactivated (disconnect the terminals B and C, connect the terminals A and C), and
the lamp 2 is turned off.
Press and hold button 3 of the transmitter: The relay of the receiver 3 is activated (connect the terminals B and C, disconnect the terminals A and C),
and the lamp 3 is turned on.
Release button 3 of the transmitter: The relay of the receiver 3 is deactivated (disconnect the terminals B and C, connect the terminals A and C), and
the lamp 3 is turned off.
Press and hold button 4 of the transmitter: The relay of the receiver 4 is activated (connect the terminals B and C, disconnect the terminals A and C),
and the lamp 4 is turned on.
Release button 4 of the transmitter: The relay of the receiver 4 is deactivated (disconnect the terminals B and C, connect the terminals A and C), and
the lamp 4 is turned off.
3) Setting Interlocking mode: Disconnect Jumper-1 and Jumper-2.
Mode Interlocking (working with transmitter C-4): Press -> On; Press another button -> Off.
Press button 1 of the transmitter: The relay of the receiver 1 is activated (connect the terminals B and C, disconnect the terminals A and C), and the
lamp 1 is turned on. The relays of the receivers 2, 3, 4 are deactivated (disconnect the terminals B and C, connect the terminals A and C), and the
lamps 2, 3, 4 are turned off.
Press button 2 of the transmitter: The relay of the receiver 2 is activated (connect the terminals B and C, disconnect the terminals A and C), and the
lamp 2 is turned on. The relays of the receivers 1, 3, 4 are deactivated (disconnect the terminals B and C, connect the terminals A and C), and the
lamps 1, 3, 4 are turned off.
Press button 3 of the transmitter: The relay of the receiver 3 is activated (connect the terminals B and C, disconnect the terminals A and C), and the