1.3 Front Panel Features

POWER ON/OFF SWITCH: AC mains switch and high voltage in “ON” position
HV LED: Indicates the high voltage supply is ON and the fuse is intact.
BIAS L led: Indicates the Bias voltage for Left channel (Left chassis side for Mono)
BIAS R led: Indicates the Bias voltage for Right channel (Right chassis side for Mono)
OPERATE/STANDBY SWITCH: Turns filaments on in the “OPERATE” position.

1.4 Rear Apron Features

INPUTS RCA or XLR: Signal input connection via shielded interconnect cable
RCA/ XLR SWITCH: Switches between RCA and XLR input selection.
SPEAKER OUTPUT: Three- 5-way binding posts provide the signal output to the
   

speaker system. Red = +, 4 or 8 ohms, Black = -, ground

BIAS JACK: _” ‘phone plug’ jack  for  supplied  cable  with  plug  to  measure  the  output
tube bias levels. See tube bias instruction sheet later in the manual.
BIAS POTENTIOMETER: Adjusts to achieve the bias level setting for the output tubes.
AC:  3- conductor shielded power detachable cord to AC power mains.

POWER AC FUSE: This is an over current protection fuse for the power transformer.
                             Never replace with any other fuse than 3 AMP SLOW BLOW!
                             250 VOLT!  (2 AMP SLOW BLOW IN 220 VAC OPERATION)

FILAMENT FUSE: This is an over current protection fuse for the filament transformer.
                            Never replace with any other fuse than a 2 AMP SLOW BLOW!
                            (1 AMP SLOW BLOW IN 220 VAC OPERATION.)     

LEFT AND RIGHT TUBE (side) FUSE: This is a protection fuse for  the  output  tubes.
Never replace it with any other fuse than a 0.5 amp fast blow! 0.5A @ 250 volt rating.

1.5 TOP PANEL FEATURES

TRIODE / ULTRA-LINEAR SWITCHES:  Three  mode  switches  per  chassis  side  allow
you to choose from 50 watts (100 watts mono) power in Triode mode or  100  watts
(200 watts mono) power in Ultralinear  mode. All mode switches  should  be set to the
same ‘direction.’

RED LED: (‘Good  Health  LED’)  Indicator  for  each individual  output  tube.  When  the
LED is lit it shows that the associated output tube is working.

CAUTION

EQUIPMENT DAMAGE MAY OCCUR WITH IMPROPER RATED FUSES

CAUTION

NEVER REMOVE or THE INSERT AC LINE CORD WHEN THE UNIT IS ON TO

AVOID RISK OF ELECTRICAL SHOCK

Содержание CAD-280 SA V-12R

Страница 1: ...stalling your new V 12R power amplifier please read this manual carefully as it will inform you of the specifications proper installation procedures and operation procedures Also included in this manual are guidelines on how to properly service and care for your new CAD 280 SA V 12R stereo or mono power amplifier ...

Страница 2: ...tts Ultralinear Mode 200 watts Ultralinear Mono INPUT SENSITIVITY 1 3 volts for full output INPUT IMPEDANCE 150 000 ohms NOISE AND HUM 84db below rated output FREQUENCY RESPONSE 20Hz to 23Khz 1 0 dB at full power TUBES 2 12BZ7 Input tubes or 12AY7 12AX7 2 EL 84 Current Source tubes or 6BQ5 12 EL 34 Output tubes or 6550 KT 66 KT 77 KT 88 KT 90 6L6 POWER TRANSFORMER 1 EI laminated 200 duty cycle OUT...

Страница 3: ... power detachable cord to AC power mains POWER AC FUSE This is an over current protection fuse for the power transformer Never replace with any other fuse than 3 AMP SLOW BLOW 250 VOLT 2 AMP SLOW BLOW IN 220 VAC OPERATION FILAMENT FUSE This is an over current protection fuse for the filament transformer Never replace with any other fuse than a 2 AMP SLOW BLOW 1 AMP SLOW BLOW IN 220 VAC OPERATION L...

Страница 4: ...from your Cary Audio Authorized Dealer with the packing cartons should you ever need it Failure to register your warranty will set the limited warranty time period to 90 days from date of purchase When purchased from a Cary Audio Authorized Dealer and properly registered the limited warranty period is extended See the limited statement of warranty for details 2 3 Amplifier Placement In general the...

Страница 5: ...The speaker cables from the output posts of the CAD 280 SA to the speaker system can be any convenient length your set up requires Select speaker cables of sufficient ...

Страница 6: ...st 4 or 8 ohm for the speaker s in your system The selection should be based on your current speakers rated specifications and listening tests to confirm the correct connection 3 3 Triode or Ultra Linear Mode Switches Select either the Triode 50 100 Mono watts or Ultra Linear 100 200 Mono watts output setting Make sure all six switches are set to the same operating mode position You can switch bet...

Страница 7: ... be used in the V 12R power amplifiers 6L6 6V6 KT 66 KT 88 6550C KT 90 KT 99 or EL 34 tubes are all acceptable for use in the output stage 4 3 IN FACTORY SERVICE Careful consideration has been given to the design of your V 12R amplifier to keep maintenance problems to a minimum However it is possible that some problems may arise which cannot be cured by a vacuum tube substitution At this point we ...

Страница 8: ...RVICE WITH THE BOTTOM PLATE REMOVED CONTACT WITH THE HIGH VOLTAGES FOUND INSIDE THE CHASSIS CAN BE FATAL COMPLETELY REMOVE AC POWER PLUG FROM THE WALL AND ALLOW 30 MINUTES FOR THE HIGH VOLTAGE CAPACITORS TO DISCHARGE THROUGH BLEEDER RESISTORS BEFORE ATTEMPTING TO CHANGE TUBES OR CLEAN THE INSIDE OF THE AMPLIFIER CAUTION NEVER REMOVE OR INSERT AC PLUG WHEN THE UNIT IS ON OR THE AC POWER SWITCH IS I...

Отзывы: