- 5 - 

 

STEP 9 

 

Plug in AC Cord. 
 
NOTE:  Sometimes when the AC Cord is 
new it does not want to go in all the way.  
Push firmly to force it in, if that is the 
case. 

 
 
 

 
 
 
 

STEP 10 

 

Turn the Power Button ON.  Wait 2 
minutes for the amp to get hot, after the 2 
minutes you should see the meter read 
current.  Your Meter will start low then 
increase up to 80mA, adjust it accordingly. 
 
NOTE:  Do Not turn ON the Standby 
switch, leave it on STANDBY.   

 
 
 

STEP 11 

 

Check your meter at this point, if it goes 
over 80mA, lower it by turning the bias 
potentiometer with the screw driver, clock 
wise, if it’s under 80mA bring it up by 
turning the potentiometer the other way.   

 
 
 
 

Bias Potentiometer above. 

 
 