TYPICAL STEREO SETUP
MONO MAINS & MONITORS
STEREO BIAMPING
CHANNEL TWO
HIGH
PHASE
MID
PHASE
LOW
PHASE
XC3000
Electronic Crossover
1-800-854-2235
www.carvin.com
INTERNAL FUSE
90-250 VAC
10 VA ~50-60HZ
GND
LIFT
CHANNEL ONE
HIGH
PHASE
MID
PHASE
LOW
PHASE
MONO
[ LOW 1+2 ]
SWITCHABLE
TO MONO
[ LOW 1+2]
PROFESSIONAL STEREO
POWER AMPLIFIER
SERIAL NUMBER
120V~60Hz Slow Blow
FUSE 8AG 700VA
+ ––BRIDGE–– +
–
–
SPEAKER
2
SPEAKER
1
GND LIFT
PARALLEL
BRIDGE
LIMITERS
CH1
IN
XLR
PIN 1 GND
PIN 2 POS
PIN 3 NEG
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION - TO PREVENT ELECTRICAL SHOCK DO NOT DEFEAT THE SAFETY
GROUND ON THE POWER CORD - DO NOT REMOVE COVER .
WARNING - TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE TO RAIN
OR MOISTURE. REFER SERVICING TO QUALIFED PERSONNEL.
PROFESSIONAL STEREO
POWER AMPLIFIER
SERIAL NUMBER
120V~60Hz Slow Blow
FUSE 8AG 700VA
+ ––BRIDGE–– +
–
–
SPEAKER
2
SPEAKER
1
GND LIFT
PARALLEL
BRIDGE
LIMITERS
CH1
IN
XLR
PIN 1 GND
PIN 2 POS
PIN 3 NEG
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION - TO PREVENT ELECTRICAL SHOCK DO NOT DEFEAT THE SAFETY
GROUND ON THE POWER CORD - DO NOT REMOVE COVER .
WARNING - TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE TO RAIN
OR MOISTURE. REFER SERVICING TO QUALIFED PERSONNEL.
Left Input
Left Low Out
Left High Out
Right High Out
Right Low Out
Right Input
STEREO CROSSOVER
Suggested settings
Low/Hi 1k - 2.5kHz
Low Frequency Amp
High Frequency Amp
Left Lows
Right
Lows
Right Highs
Left Highs
PROFESSIONAL STEREO
POWER AMPLIFIER
SERIAL NUMBER
120V~60Hz Slow Blow
FUSE 8AG 700VA
+ ––BRIDGE–– +
–
–
SPEAKER
2
SPEAKER
1
GND LIFT
PARALLEL
BRIDGE
LIMITERS
CH1
IN
XLR
PIN 1 GND
PIN 2 POS
PIN 3 NEG
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION - TO PREVENT ELECTRICAL SHOCK DO NOT DEFEAT THE SAFETY
GROUND ON THE POWER CORD - DO NOT REMOVE COVER .
WARNING - TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE TO RAIN
OR MOISTURE. REFER SERVICING TO QUALIFED PERSONNEL.
For (stereo) the PARALLEL
switch must be OFF (OUT).
Ch 1 Left
Ch 2 Right
BRIDGE switch
must be OFF (OUT).
Right Full Range
Left Full Range
PROFESSIONAL STEREO
POWER AMPLIFIER
SERIAL NUMBER
120V~60Hz Slow Blow
FUSE 8AG 700VA
+ ––BRIDGE–– +
–
–
SPEAKER
2
SPEAKER
1
GND LIFT
PARALLEL
BRIDGE
LIMITERS
CH1
IN
XLR
PIN 1 GND
PIN 2 POS
PIN 3 NEG
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION - TO PREVENT ELECTRICAL SHOCK DO NOT DEFEAT THE SAFETY
GROUND ON THE POWER CORD - DO NOT REMOVE COVER .
WARNING - TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE TO RAIN
OR MOISTURE. REFER SERVICING TO QUALIFED PERSONNEL.
Mains
Monitors
Mains
Ch 1 Main Mix
Ch 2 Monitor Mix
BRIDGE switch
must be OFF (OUT).
The PARALLEL switch
must be OFF (OUT).
25V OR 70V DISTRIBUTION SYSTEM
BRIDGED MONO
BRIDGED MONO
SHIELD
-NEG.
3
1
2
+POS.
SHIELD
-NEG.
3
1
2
+POS.
GND
- SIGNAL (BAL.)
+ SIGNAL (BAL.)
BALANCED MIC/LINE XLR CABLES
HELPFUL HINTS
Twist-Lok
Twist-Lok
Housing
Contact
Insert
Cable
Clamp
Securing
Hub
• Connection Configuration:
Black (1+) / pos. full range mode, Low pos. Bi amp mode
White (1-) / neg. full range mode, Low neg. Bi amp mode
Red (2+) / not used
Green (2-) / not used
• Solder wires in contacts or use hex screws provided.
• Slip "Securing Hub" then "Cable Clamp" over cable before attaching wires.
1+
1-
2+
2-
Solder tinned wires 1/4"
Strip cable insulation back 3/4"
1
2
3
PROFESSIONAL STEREO
POWER AMPLIFIER
SERIAL NUMBER
120V~60Hz Slow Blow
FUSE 8AG 700VA
+ ––BRIDGE–– +
–
–
SPEAKER
2
SPEAKER
1
GND LIFT
PARALLEL
BRIDGE
LIMITERS
CH1
IN
XLR
PIN 1 GND
PIN 2 POS
PIN 3 NEG
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION - TO PREVENT ELECTRICAL SHOCK DO NOT DEFEAT THE SAFETY
GROUND ON THE POWER CORD - DO NOT REMOVE COVER .
WARNING - TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE TO RAIN
OR MOISTURE. REFER SERVICING TO QUALIFED PERSONNEL.
PARALLEL switch OFF (OUT).
To signal socket XLR or 1/4" 2 or 3 cond. shielded
Activate the BRIDGE switch
(IN). Control the level by Ch 1
(Ch 2 does not function.)
Ch 1 Input
Single speaker or
system connected
in BRIDGE mode.
Minimum imp. 4
Ω
Use either the Bridged
Twist-Lok connector or the
binding posts. No other
connections can be used
while in Bridged mode.
PROFESSIONAL STEREO
POWER AMPLIFIER
SERIAL NUMBER
+ ––BRIDGE–– +
–
–
SPEAKER
2
SPEAKER
1
GND LIFT
PARALLEL
BRIDGE
LIMITERS
CH1
IN
XLR
PIN 1 GND
PIN 2 POS
PIN 3 NEG
25V or 70V
Distribution System:
Wattage of transformer (TAP)
divided by total wattage
of Amp = Number of
transformer/speaker(s)
that can be hooked up.
+
16
8
4
C
15w
7w
3w
1w
C
+
16
8
4
C
15w
7w
3w
1w
C
6) MAIN AC BREAKER TRIPS: Each high powered amp may require
a separate 20 amp circuit breaker (230V: 10 amp) for delivering
full power. Note: Some 120V homes have only 15 amp breakers.
1) NO SOUND FROM CH 2: The rear recessed BRIDGE switch
has been inadvertently pushed in.
2) STEREO CHANNELS SOUND THE SAME: The rear
PARALLEL switch has been inadvertently pushed in.
3) NO HIGH FREQUENCIES: Tweeters or midrange drivers have
been damaged or blown from feedback or overpowering.
4) SYSTEM HUM: Try switching the GND LIFT switch IN or OUT
(depending on your use). If hum is not eliminated, then use Carvin’s
MTF55 XLR cable ground lifter by connecting it inline to your XLR
cable(s).
5) POOR SOUND (BASS): The speaker systems are wired out
of phase to each other. To correct, reverse the wires on one
speaker connector only and your bass response will improve.
Input