Carver Xi1850 Скачать руководство пользователя страница 7

Installation

Location and General Precautions

Observe the following precautions when choosing a location for your amplifier.

A.  Do not expose the unit to rain or moisture.  If a fluid or foreign object should enter the unit,

disconnect the power plug and contact an authorized dealer or service center.  Do not pull out

the plug by pulling on the cord; grasp the plug firmly and pull from socket.

B.  Protect from heat and allow adequate ventilation.  Place away from direct sources of heat,

such as heating vents and radiators.  All components produce some heat during operation, so

make sure that the ventilation holes are not covered and that air is allowed to circulate freely

behind, beside and above the amplifier.  Excessive heat is the single greatest cause of  component

failure.

Mechanical Considerations

The Xi1850 and Xi2600 require three rack space units (5.25”) and a depth of 16” inside the rack,

including the rear supports.  Secure the unit mechanically using four screws with washers to

prevent marring the front panel.

Rear Support for Road Applications

If the Xi amplifier is rack mounted and the rack is transported, mechanical support for the rear

of the amplifier is required.  This could take the form of a shelf across the rear of the amplifier

or brackets that engage the rear of the amplifier.  Rear support is recommended in all Xi amplifier

installations.

Thermal Considerations

When the Xi amplifiers are used free-standing, no thermal considerations are necessary other

than keeping the ventilation holes open.  If the amplifiers are rack mounted, ensure that adequate

ventilation exists if front of and behind the amplifier.  When several amplifiers are mounted

together in a rack, you may need to provide air inlets from the outside of the rack.  The Xi

amplifiers are fan cooled.  The fan is internally mounted so that it draws air from the rear of the

chassis and exhausts it out the front.  The Xi amplifiers may be stacked directly on top of each

other without spacer panels.  If the amplifiers are used with other amplifiers, ensure that the heat

output from the other amplifiers does not interfere with the ventilation of the Xi amplifiers (or vice

versa).

AC Power Considerations

Ensure that the Xi amplifier is plugged into an outlet capable of supplying the correct voltage

specified for your model and enough current to allow full-power operation of all amplifiers plugged

into the outlet.  The current demand of a power amplifier varies depending on several factors,

including the impedance of the load, the output level of the amplifier, and the crest factor and

duty cycle of the program material.  Under typical conditions reproducing rock music, with both

channels driven into a 4 ohm load to the point where musical peaks are just at the clipping point,

the amplifiers require the following current:

Xi1850: 

525W (7.2A) for 117V versions, 525W (3.5A) for 234Vversions

Xi2600: 

700W (10A) for 117V versions, 600W (4.0A) for 234V versions

Magnetic Leakage Considerations

The Xi amplifiers may be mounted without concern for magnetic flux leakage, within the confines

of common sense.  For example, it is not a good idea to mount a power amplifier near a

microphone input transformer or magnetic storage media.

The input signal can be used with either  unbalanced shielded single conductor or balanced shielded

two conductor cables.  Use shielded cable to conduct the signal from the source (i.e. mixer, equalizer,

CD player, etc.) to the amplifier.

For Balanced Operation:

1/4” Phone Jack:

  Use a 3-conductor TRS

(tip-ring-sleeve) 1/4” Phone Plug.  The tip

carries the “+” (high, non-inverted) side of the

signal, the ring carries the “-” (low, inverted)

side of the signal and the sleeve is signal ground

(see Figure A).

XLR:  

Use a male XLR connector.  Pin 2 carries

the”+” (high, non-inverted) side of the signal,

Pin 3 carries the “-” (low, inverted) side of the

signal and Pin 1 is signal ground. (See Figure B).

For Unbalanced Operation:

1/4” Phone Jack:

  Use a 3-conductor TRS

(tip-ring-sleeve) 1/4” Phone Pug.  The tip

carries the “+” (high, non-inverted) side

of the signal, the sleeve is signal ground

connect the sleeve to the ring.

(see Figure C).

XLR:  

Use a male XLR connector.  Pin 2

carries the”+” (high, non-inverted) side of

the signal, Pin 1 is signal ground, Pin 3 is

jumpered to Pin 1. (See Figure d).

Input Sensitivity

The input sensitivity of the Xi amplifiers

is set at the factory to 1.55V

RMS

 for rated

output.  The input sensitivity can be

changed to 0.775V

RMS

 by using the

appropriate DIP switch on the rear panel.

The input sensitivity can be set

independently for each channel.

Figure B

Balanced Connection

Balanced Connection

1

2

3

Figure A

Unbalanced Connection

Unbalanced Connection

Better Method

Optional Method

Better Method

Optional Method

1

2

3

1

2

3

Figure C

Figure D

7

All manuals and user guides at all-guides.com

Содержание Xi1850

Страница 1: ...anual A Product of Phoenix Gold International Inc 9300 North decatur Street Portland Oregon 97203 Tel 503 286 9300 Fax 503 978 3302 www carverpro com All manuals and user guides at all guides com a l...

Страница 2: ...o rain or moisture does not operate normally or has been dropped TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE TO PREVENT ELECTRIC SHOCK DO NOT REMOVE T...

Страница 3: ...our Xi Series amplifier will give you many years of outstanding service and reliability Unpacking Inside the box you will find one Xi Series Amplifier four self adhesive rubber feet and an owner s man...

Страница 4: ...n 1 THD N 2600W bridged mono into 4 ohms 1 kHz with less than 1 THD N FEATURES Stable 2 Ohm operation Variable speed ultra quiet fan cooling 7 LED level display per channel including signal present an...

Страница 5: ...per channel and one Yellow Standby indicator per channel 3 Channel 2 Level Control is a 41 detent potentiometer allowing adjustment from infinite attenuation to 0dB attenuation in 40 steps Level contr...

Страница 6: ...wire are bridging between the connectors This can be simplified by not stripping an excessive amount of insulation from the speaker wire 5 Channel 1 Multi way Binding post speaker connectors Red is p...

Страница 7: ...ge specified for your model and enough current to allow full power operation of all amplifiers plugged into the outlet The current demand of a power amplifier varies depending on several factors inclu...

Страница 8: ...s in Bridged Mono mode see the paragraph above refencing Speakon NOTE Be sure to set both CH1 and CH2 input level controls to the same setting for equal power distribution to the inverted and non inve...

Страница 9: ...0 80 2 0W When used in a 70 7 volt distribution system this transformer s new tap values are as noted above Note that the 3dB power relationship between each tap still holds true Similarly maximum am...

Страница 10: ...al damages which may result from failure of this product If your Carver Professional product proves defective in material or workmanship the liability of Carver Professional shall be limited to the re...

Страница 11: ...n the cable 4 Make sure the speakers are functioning correctly 5 If you are using bridged mono mode ensure that the Input and Output configurations are set correctly 6 Use a voltmeter to determine if...

Страница 12: ...r Professional 9300 North Decatur Street Portland Oregon 97203 Phone 503 286 9300 Fax 503 978 3302 Email support carverpro com Web www carverpro com 8100 0305A All manuals and user guides at all guide...