5
LOCATION
Read equipment manual completely before installing and op-
erating the cabinet.
Unit must be installed by qualified service personnel on-
ly
. Unit must be installed in such a fashion to bear the weight
of the cabinet when fully loaded; minimum 350 pounds.
The power connection for each heater is a grounded plug.
Electrical information for each heater is provided on the
heat-
er
serial tag on the front of each heater. Verify that the proper
electrical service required for this cabinet is available prior to
installation. Plug the power cords into grounded outlets with a
electrical service according to the electrical information pro-
vided on page 3.
INSTALLATION and START-UP
GROUNDING INSTRUCTIONS
This appliance is equipped with cords having a grounding wire with
a grounding plug which must be plugged into an outlet that is
properly installed and grounded. In the event of an electrical short
circuit, grounding reduces the risk of electric shock by providing an
escape wire for the electric current.
WARNING—Improper use of the grounding can result in a risk
of electric shock.
Consult a qualified electrician or service agent if
the grounding instructions are not completely understood, or if doubt
exists as to whether the appliance is properly grounded.
If necessary, contact a licensed
electrician to install an appropriate
15 amp electrical circuit with correct
NEMA receptacle for each heater.
DO NOT use an extension cord.
Installation procedures must be
performed by a qualified technician
with full knowledge of all applicable
electrical codes and with proper
load-bearing hardware. Failure
could result in personal injury and
property damage.
Damage to unit due to being
connected to the wrong voltage or
phase is
NOT
covered by warranty.
START-UP
1. Prior to use, thoroughly clean the interior of the unit, per
the instructions in this manual (page 8).
2. Plug the power cord of the cabinet into grounded outlets
with a electrical service according to the electrical infor-
mation provided on page 3. Set POWER switches to the
“ON” position.
3. Do not load product into the cabinet. Allow the heat to
remove any residual oils which may adhere to inside met-
al surfaces. A slight emission of smoke is common dur-
ing the first few hours of operation.
T
he ground prong of the power
cord is part of a system designed to
protect you from electric shock in
the event of internal damage.
DO NOT cut off the large round
ground prong or twist a blade to fit
an existing receptacle.
CAUTION:
Electrical Shock Hazard
Unit is not waterproof, to avoid
electrical shock, keep unit and
counter from being submerged in
water. Do not operate if unit has
been in contact with water.
IMPORTANT:
Each power cord is 6' long
IMPORTANT:
Not under warranty
WARNING:
Risk of personal injury
WARNING:
Risk of personal injury
Heater serial tag locations
Cabinet serial tag (Note
serial number if calling
for service)