5

THERMOSTAT LIMITED WARRANTY

CARRIER CORPORATION

Limited Warranty for Thermostats

FOR WARRANTY SERVICE OR REPAIR:

For Warranty Service or Repair: Visit www.carrier.com/homecomfort or contact Carrier Corporation Customer Relations at 1- 800- 227- 7437

for instructions.

PRODUCT REGISTRATION:

You can register your product online at

www.carrier.com

.

Model Number_________________________________________________ Serial Number__________________________________

Date of Installation______________________________________________

Installed by____________________________________

Name of Owner_________________________________________________ Address of Installation____________________________

Carrier Corporation (hereinafter “Company”) warrants this product against failure due to defect in materials or workmanship under normal
use and maintenance as follows. All warranty periods begin on the date of purchase. If a part fails due to defect during the applicable warranty
period Company will provide a new or remanufactured part, at Company’s option, to replace the failed defective part at no charge for the part.
Alternatively, and at its option, the Company will provide a credit in the amount of the then factory selling price for a new equivalent part
toward the retail purchase price of a new Company product. Except as otherwise stated herein, those are Company’s exclusive obligations
under this warranty for a product failure. This limited warranty is subject to all provisions, conditions, limitations and exclusions listed below
and on the reverse (if any) of this document.

RESIDENTIAL APPLICATIONS
This warranty is to the original owner and subsequent owners only to the extent and as stated in the Warranty Conditions and below. The
limited warranty period in years for residential applications, depending on the part and the claimant, is as shown in the table below.

Limited Warranty (Years)

Product

Original Owner

Subsequent Owner

TC- PBO01- BLK, TC- PHP01- BLK,

TC- WHS01- BLK Thermostat

3

3

OTHER APPLICATIONS
For all applications other than residential applications, the warranty period is one (1) year. The warranty is to the original owner only and is
not available for subsequent owners.

LEGAL REMEDIES

: The owner

must

notify the Company in writing, by certified or registered letter to Carrier Corporation, Warranty

Claims, P.O. Box 4808, Syracuse, New York 13221, of any defect or complaint with the product, stating the defect or complaint and a specific
request for repair, replacement, or other correction of the product under warranty, mailed at least thirty (30) days before pursuing any legal

rights or remedies.

Содержание TC-PBO01-BLK

Страница 1: ...started COMPATIBLE HEATING AND COOLING SYSTEMS This thermostat works with many centralized residential heating and cooling systems S Conventional Heating and Cooling AC one stage of heating and one stage of cooling S Heat Pump HP two stages of heating and one stage of cooling S Heat pumps work to provide cooling in the summer but in the winter they do it in reverse drawing their heat energy from t...

Страница 2: ...your heating and cooling system S You can do this either at your circuit breaker box or a switch at your indoor furnace or fan coil S Most systems have one switch but some systems have two switches 2 Make sure your system is without power by using your old thermostat to adjust the temperature Your system should not turn on or A150046 Warning Electrical operation hazard Failure to follow this warni...

Страница 3: ...ked J2 on the thermostat display s circuit board a If you connected a Common C wire put J2 in the 24VAC position b If you did not connect a Common C wire leave J2 in the default BATT position J2 24VAC BATT SST B D10 D9 Q9 R6 C23 R48 R107 C48 J2 24VAC BATT SST B D10 D9 Q9 R6 C23 R48 R47 R107 C48 With Common Wire Connected NO Common Wire Connected A150242 Step 6 CONNECTING THE DISPLAY 1 With the Car...

Страница 4: ...ult Fahrenheit F Selections Fahrenheit F Centigrade C Description This selection operates the thermostat in either Fahrenheit or Centigrade Option 04 G fan ON with W Heat Selection Default G not energized with W OF Options G not energized with W OF G energized with W ON Description This selection determines whether the fan G is to be ON or OFF when W furnace or strip heat is ON Furnaces and fan co...

Страница 5: ...button again This will stop continuous fan oper ation FAN ON icon will turn off Heating Operation 1 Press MODE button until HEAT is displayed 2 Press UP button until LCD readout reads 3_F 2_C above room temperature Press UP and FAN buttons simultane ously to defeat timers Heating system should begin to oper ate immediately 3 For Heat Pump HP applications only press MODE button until EMHT emergency...

Страница 6: ...he Y output will energize first then 15 minutes later W is allowed to come on if the thermostat determines it is not satisfying the demand However if the heating demand is greater than 5 F 3 C there will be only a 30 second delay before bringing on W TROUBLESHOOTING Your thermostat does not power on Check the following 1 Turn off the power to your system Check that all wires are properly inserted ...

Страница 7: ...ly changeover between Heat and Cool 4 Thermostat mode is Off 5 Temperature set point indicator 6 Temperature displayed in Fahrenheit or Celsius 7 Current Indoor Temperature 8 Battery strength indicator 9 Period of day for programming mode 10 Day s of the week for programming mode 11 Time 12 Programming mode 13 System is in auxiliary supplemental mode 14 System is in hold 15 AM or PM indicator for ...

Страница 8: ...t Schedule If you choose to change any of your weekly schedule press SET at any time You will enter the programming schedule with weekdays morning period You are ready to set the new starting time for the morning period One press of the TEMP TIME button and you are ready to set the new morning temperature To set values for other periods use the SET button To set values for other days use the DAY b...

Страница 9: ...ies are the power source for the thermostat If batteries are used with your equipment then they should last about one year As the batteries lose their power a battery icon appears on the display showing one black bar and then none As the icon becomes empty you will begin to lose thermostat functions because the batteries are losing their power When the batteries are completely dead you won t be ab...

Страница 10: ...Corp S 7310 W Morris St S Indianapolis IN 46231 Edition Date 01 17 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No OM TCPBO01BLK 01 Replaces NEW ...

Страница 11: ...factory selling price for a new equivalent part toward the retail purchase price of a new Company product Except as otherwise stated herein those are Company s exclusive obligations under this warranty for a product failure This limited warranty is subject to all provisions conditions limitations and exclusions listed below and on the reverse if any of this document RESIDENTIAL APPLICATIONS This w...

Страница 12: ... not installed pursuant to any applicable governmental minimum efficiency standards 3 Normal maintenance as outlined in the installation and servicing instructions or Owner s Manual 4 Failure damage or repairs due to faulty installation misapplication abuse improper servicing unauthorized alteration or improper operation 5 Failure to start or damages due to voltage conditions blown fuses open circ...

Отзывы: