2.2 Manual Operation
Manual operation is available to control the unit when your remote is unavailable.
ACCESS
Open the front panel by carefully
lifting both ends at the same time.
Once lifted sufficiently, a click is heard
and it becomes self-supporting.
OPERATE
Press the manual button repeatedly to change modes as follows;
a Once = AUTO mode [heat, cool or fan 24°C and auto fan speed].
b Twice=COOLING mode [ switches to AUTO mode after 30 minutes (mainly used for
testing purpose)].
c Three times = OFF.
COMPLETE
Close the panel by firmly tugging downwards on both ends until it returns to its original
position.
RESTORE
Using the remote controller will return the unit to normal operation.
2.1 Operating temperature
2.3 How It Works!
● In this setting the system will automatically change modes and fan speed to the set
temperature.
● [In spring and autumn, closer temperature control may require
COOL/HEAT mode
changes.]
In this mode, priority is given to dehumidifying the air. Low fan speed and compressor
cycling is used to achieve this and regulate room temperature.
When selected, the set temperature will increase
(cooling) or decrease (heating) by 1°C
per hour for the first 2 hours. Thereafter it
keeps this new temperature for 5 hours
before switching off.
This operation saves energy and improves night time comfort by synchronising with the
body’s metabolism.
AUTO Mode
DRY Mode
SLEEP Mode
Hints For Economical Operation
● Adjust the temperature to achieve moderate comfort levels.
● Excessively low or high temperatures waste energy.
● Improve performance by keeping windows and doors closed.
● Limit energy usage [run time] by using the TIMER function.
● Do not block air inlets or outlets. Poor performance, increased running costs and
reduced product life will result.
● Inspect the air filters periodically, and clean them when needed.
Please clean
cold
hot
Please close
Basic Operation Modes
:
AUTO / COOL / DRY / HEAT / FAN
OPERATION
Indoor
Outdoor
-10°C DB
Upper limit
27°C DB
24
°C
DB
Lower limit
0°C DB
-15
°C
DB
Cooling
operation
Upper limit
32°C DB
Lower limit
18°C DB
Heating
operation
Note: DB - Dry Bulb
1. Optimum performance will be achieved within these operating temperatures.
2. When the unit operates above or below these conditions for a long time, system diagnostics may detect a malfunction
and the unit will not operate properly.
3. Room relative humidity - less than 80%. If the air conditioner operates outside this range, the surface of the air conditioner
may attract condensation. Please set the air flow louver to its maximum angle and set HIGH fan mode.
Use the timer
effectively
Manual Button
AUTO/COOL
46°C DB