![Carrier Performance 13 38TXA Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/carrier/performance-13-38txa/performance-13-38txa_product-data_2561432033.webp)
33
Detailed cooling capacities* continued
See notes on pg. 38.
EVAP
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75
85
95
105
115
125
CFM
EWB
Capacity
MBtuh†
Total
Sys
kW**
Capacity
MBtuh†
Total
Sys
kW**
Capacity
MBtuh†
Total
Sys
kW**
Capacity
MBtuh†
Total
Sys
kW**
Capacity
MBtuh†
Total
Sys
kW**
Capacity
MBtuh†
Total
Sys
kW**
Total Sens‡
Total Sens‡
Total Sens‡
Total Sens‡
Total Sens‡
Total Sens‡
38TXA042-33 Outdoor Section With CD5AA048 Indoor Section
1225
72
46.7
22.7
2.49
45.2
22.3
2.77
43.3
21.6
3.09
41.2
20.9
3.44
38.8
20.1
3.83
36.0
19.2
4.26
67
44.0
29.5
2.47
42.3
28.9
2.75
39.8
27.8
3.05
37.7
27.1
3.40
35.4
26.3
3.79
31.4
24.7
4.18
63††
40.5
28.7
2.44
37.8
27.5
2.70
35.0
26.3
3.00
32.0
25.0
3.32
30.2
24.3
3.70
27.8
23.3
4.11
62
39.3
35.4
2.43
36.7
34.1
2.69
33.9
32.7
2.98
31.1
30.9
3.31
29.5
29.5
3.69
27.9
27.9
4.11
57
36.4
36.4
2.40
34.3
34.3
2.67
32.1
32.1
2.96
30.8
30.8
3.30
29.4
29.4
3.69
27.7
27.7
4.11
1400
72
47.1
23.3
2.55
45.8
23.0
2.83
43.9
22.5
3.15
41.8
21.8
3.51
39.3
21.1
3.90
36.5
20.2
4.33
67
44.3
30.5
2.52
42.7
30.2
2.81
40.5
29.4
3.12
38.4
28.8
3.47
35.9
27.9
3.85
31.7
26.4
4.25
63††
42.1
30.7
2.51
39.3
29.5
2.78
36.4
28.3
3.07
33.6
27.1
3.40
31.8
26.3
3.79
27.9
24.7
4.18
62
40.5
37.9
2.50
37.8
36.5
2.76
35.0
34.8
3.06
32.7
32.7
3.39
31.2
31.2
3.78
29.5
29.5
4.21
57
38.1
38.1
2.48
36.2
36.2
2.74
35.0
35.0
3.05
33.6
33.6
3.40
32.2
32.2
3.79
29.3
29.3
4.20
1575
72
47.5
23.9
2.61
46.2
23.7
2.90
44.4
23.2
3.22
41.8
22.4
3.56
39.5
21.8
3.95
36.8
21.1
4.40
67
44.9
31.9
2.58
43.0
31.5
2.86
41.1
31.1
3.18
38.8
30.3
3.53
36.3
29.6
3.92
32.0
28.0
4.32
63††
42.5
32.0
2.57
40.5
31.4
2.85
37.6
30.1
3.15
35.0
29.1
3.48
33.1
28.3
3.87
27.9
26.0
4.24
62
41.6
40.2
2.57
38.9
38.5
2.83
36.5
36.5
3.13
35.4
35.4
3.49
32.7
32.7
3.86
30.7
30.7
4.29
57
40.7
40.7
2.56
39.0
39.0
2.83
37.6
37.6
3.15
35.8
35.8
3.49
33.5
33.5
3.87
30.7
30.7
4.29
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Power
Capacity
Power
CC5A/CD5AA
042
1.00
1.01
CC5A/CD5AC
048
0.99
0.94
CC5A/CD5AC
048
0.99
1.01
CD5AA
048
1.00
0.94
CC5A/CD5AW
048
1.00
1.00
CE3AA
042
1.00
0.95
CD5AA
048
1.00
1.00
048
1.01
0.95
CE3AA
042
1.01
1.01
CK3BA
042
1.00
0.95
048
1.01
1.00
048
1.00
0.94
CF5AA
048
1.00
1.00
CK5A/CK5BA
042
0.99
0.93
CK3BA
042
1.00
1.00
048
1.00
0.94
048
1.00
1.00
CK5A/CK5BE
042
1.00
0.94
CK5A/CK5BA
042
1.00
1.00
CK5A/CK5BT
042
1.00
0.95
048
1.00
1.00
048
1.00
0.94
CK5A/CK5BE
042
0.98
0.97
CK5PA
042
1.00
0.95
CK5A/CK5BT
042
1.00
1.00
048
1.00
0.94
048
1.00
1.00
CK5PE
042
1.00
0.94
CK5A/CK5BW
048
1.00
1.00
CK5PT
042
1.00
0.95
CK5PA
042
1.00
1.00
048
1.00
0.94
048
1.00
1.00
COILS + 58CV(A,X)110-20 VARIABLE SPEED FURNACE
CK5PE
042
0.98
0.97
CC5A/CD5AA
042
0.99
0.94
CK5PT
042
1.00
1.00
CC5A/CD5AC
048
0.99
0.94
048
1.00
1.00
CC5A/CD5AW
042
0.98
0.93
CK5PW
048
1.00
1.00
048
1.00
0.94
F(A,B)4(A,B)N(F,B,C)
042
1.00
1.00
CD5AA
048
1.00
0.94
048
1.01
0.99
CE3AA
042
1.00
0.94
FE4ANB
006
1.02
0.89
048
1.01
0.95
FE4ANF
003
0.98
0.92
CK3BA
042
1.00
0.95
005
1.01
0.91
048
1.00
0.93
FG3AAA
048
0.99
0.99
CK5A/CK5BA
042
1.00
0.95
FK4(C,D)NB
006
1.02
0.89
048
1.00
0.94
FK4(C,D)NF
003
0.98
0.91
CK5A/CK5BE
042
1.00
0.95
005
1.01
0.91
CK5A/CK5BT
042
1.00
0.95
FV4(A,B)NB
006
1.02
0.89
048
1.00
0.94
FV4(A,B)NF
003
0.98
0.92
CK5A/CK5BW
048
1.00
0.93
005
1.01
0.91
CK5PA
042
1.00
0.95
FX4(A,B)NF
042
0.99
1.00
048
1.00
0.94
048
1.00
1.00
CK5PE
042
1.00
0.95
COILS + 58CV(A,X)090-16 VARIABLE SPEED FURNACE
CK5PT
042
1.00
0.95
CC5A/CD5AA
042
0.99
0.94
048
1.00
0.94
—
—
—
CK5PW
048
1.00
0.93