![Carrier P374-1500 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/carrier/p374-1500/p374-1500_owners-manual_2564107017.webp)
Select thermostat
operation in degrees
Fahrenheit or
Centigrade.
F
C
Setup
f
22
To Exit
Press
PROGRAM
Advanced Setup
Page 16
Step # Description Range Factory Default
1 Time of day clock set 24 hour 12:00 Am
2 Day of the week Sun - Sat Monday
3
4 Dual Fuel(on),Advanced Heat Pump(off) Off / On Off
5 Electric Heat Off / On On
6 Changeover Balance Point 32-85,OF 35
7
12
13
14 Programmable Fan
17
18
19
20 Reset Service Filter icon - - - -
21 Service Filter run time set 0 - 1950 500
22
Reversing Valve polarity O / B O
Deadband, Temperature swing 1st Stage 1 - 6 2
8 Deadband, Temperature swing 2nd Stage 0 - 10 2
9 Deadband, Temperature swing 3rd Stage 0 - 10 2
10 Minutes Between Stages 1 & 2 0- 60 2
11 Minutes Between Stages 2 & 3 0- 60 2
Forced minimum difference heat/cool 0 - 6 2
Cycles per hour d, d1, 2 - 6 6
0:00 - 0:60 0:00
15 Programmable Fan Start Time 24 hour 7:00 Am
16 Programmable Fan Stop Time 24 hour 9:00 Pm
Thermoglow backlight Off / On On
Energy Watch - Heat Timer 0 - 1999 0
Energy Watch - Cool Timer 0 - 1999 0
Fahrenheit or Centigrade F / C F
Advanced Setup Table