OWNER’S MANUAL SPLIT-SYSTEM HEAT PUMP USING R-410A REFRIGERANT: 

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

2

• Keep Filter Clean

A  clogged  or  improperly  installed  air  filter  on  your  indoor  unit  will

increase operating costs and shorten the life of  the unit.  For detailed

filter cleaning information refer to indoor unit  literature.

• Do Not Block Floor, Wall or Ceiling Vents 

When  drapes, furniture, toys or  other common  household items block

vents, the restricted airflow lessens the system’s efficiency and life span.  

• Do Not Cover or Block Outdoor Unit

The  outdoor  unit  needs  unrestricted  airflow.  Do  not  cover  it  or  place

items  on  or  next  to  it.  Do  not  allow  grass  clippings,  leaves,  or  other

debris to accumulate on the sides or top of the unit. And, maintain a 12”

(305 mm) minimum clearance between the outdoor unit and tall grass,

vines, shrubs, etc. 

• Check Condensate Drain

Your heat pump removes humidity from your home during the cooling

season. After a few minutes of operation, water should trickle from the

condensate drain of the indoor coil. Check this occasionally to be sure

the drain system is not clogged. Drainage will be limited if you live in a

very dry environment.  

• Do Not Operate Below 55°F/13°C in Cooling Mode

Your outdoor unit is not designed to operate when outdoor temperatures

are lower than 55°F/13°C without modification.  If operation below this

temperature is required, consult your authorized dealer. 

• Do Not Operate Above 66°F/19°C in Heating Mode

Your  outdoor  unit  is  not  designed  to  operate  on  heating  mode  when

outdoor temperatures are higher than 66°F/19°C.  You can safely operate

the system above 66°F/19°C on emergency or auxiliary heat. 

• Base Pan Drainage 

Periodically check for and remove debris that has settled around the base

of your outdoor unit.  This will ensure proper drainage of the base pan

and eliminate standing water inside the outdoor unit. 

• Level Installation 

Your authorized dealer will install the outdoor unit in a level position.  If

the support base settles or shifts and the unit is no longer level, be sure to

re-level it promptly to assure proper drainage. If you notice water or ice

collecting beneath the unit, arrange for it to be drained away from the

unit. 

Sea Coast Coil Maintenance

Coastal  locations  often  require  additional  maintenance  of  the  outdoor

unit due to highly corrosive airborne ocean salt. Although your new heat

pump system is made of galvanized metal and is protected by top-grade

paint, take the additional precaution of periodically washing all exposed

surfaces  and  the  outdoor  coil  approximately  every  3  months.  Consult

your  installing  authorized  dealer  for  proper  cleaning  intervals  and

procedures for your geographic area or ask about a service contract for

regularly scheduled professional cleaning and inspections. 

TROUBLESHOOTING 

Before  you  request  dealer  service,  check  for  these  easily  solved

problems: 
• Check the indoor and outdoor disconnect switches  Also check your 

main electrical panel circuit breakers or fuses.

• Check for sufficient airflow.  Air filter(s) should be reasonably clean 

and interior vents should be open and unobstructed.

• Check thermostat settings.  For cooling, your desired temperature 

setting should be LOWER than the displayed room temperature, and 

the System/Mode control should be on Cool or Auto.  For heating, 

your temperature setting should be HIGHER than the displayed room 

temperature, and the System/Mode control is set to Heat or Auto. 

• Time delays - depending on the heat pump you have, there may be 

delays in unit operation that are built-in to protect the equipment and 

your comfort.  Don’t be alarmed if you notice a time delay in 

operation.  It may be a standard protection feature of your equipment.  

Check with your authorized Dealer for more information on time 

delays.

* Monthly maintenance items and outdoor unit rinsing may be performed by the consumer. All other maintenance items and all service work must be performed by a qualified service technician. Read all waring labels.

Notes

:

1.

The above list may not include all maintenance items. Inspection intervals may vary depending on climate and operating hours. Consult your HVAC dealer about a service contract for seasonal inspections.

2.

Do not use harsh chemicals or high pressure water on coils. More frequent rinsing is required for units near a sea coast

CAUTION

!

CUT HAZARD

Failure to follow this caution may result in personal injury.
Although special care has been taken to minimize sharp edges in the
construction of your unit, be extremely careful when handling parts or
reaching into the unit. 

Maintenance Checklist

Recommended

Interval*

Outdoor unit specific:

Monthly

Annual

Clear away debris and vegetation near unit.

X

Inspect cabinet for damage. Replace components that are damaged or severely rusted.

X

Inspect electrical disconnect for proper function. Repair or replace as necessary.

X

Inspect electrical wiring and connections.  Tighten loose connections. Inspect and perform functional test of equipment as needed to ensure proper 

function. Repair or replace damaged or overheated components and wiring.

X

Check refrigerant system subcooling and/or superheat (system dependent).

X

Inspect inside of unit. Clean if debris is present.

X

Inspect condenser coil. Clean if dust, dirt, or debris is present.  Rinse unit with fresh water (see Note 2).

X

Inspect motor and fan for damage. Make sure fan spins freely.

X

Indoor specific:  (for fossil fuel furnaces and accessories, refer to unit specific literature)

Inspect, clean, or replace air filter if dirty.

X

Inspect and clean blower assembly (includes blower housing, wheel, and motor).

X

Inspect internal and external of cabinet. Clean as needed.

X

Inspect electrical disconnect for proper function. Repair or replace as necessary.

X

Inspect electrical components, wiring, and connections. Tighten loose connections. Repair or replace damaged components and wiring.

X

Inspect evaporator coil. Clean if dust, dirt, or debris is present (see Note 2).

X

Clean condensate pan, trap, and drain lines (more frequent maintenance may be required in humid climates - consult your local HVAC dealer).

X

Inspect airflow system (ductwork). Check for leaks and repair as needed.

X