background image

42PHW / 42PHQ / 42PHQ...K

GB - 7

E N G L I S H

I/O

Start / Stop
(button B)

When the air conditioner is not in operation, the remote control
readout will display the time of day only (in case other symbols are
lit, turn control off by pressing button I/O).
Press button I/O to start the air conditioner. All selected and
memorized functions will light up and appear; the unit will operate
according to the functions selected. Press button I/O to stop the air
conditioner. All indicators on the unit will go out, and the control will
display only the current time. If the unit does not stop, turn the
control on (by pressing button I/O) and repeat the operation.
If button I/O (air conditioner starting) is pressed too soon after a
stop, the compressor will not start for 3/5 minutes due to the
inherent protection against frequent compressor cycling. The unit
will only emit a “beep”, when the signals are received correctly.

MODE

Selection of the operating mode
(button C)

With this button the operating mode of the air conditioner can be
selected.
Different options are available depending on the unit model.
By repeatedly pressing this button the available modes will be
selected in sequence and the arrow will indicate the relevant
symbol, while the unit will acknowledge signal receipt with a
confirming beep.

Indicated Symbol

 

Cooling with dehumidification.

A

Heating (Heat pump model only).

A

Automatic mode.
The air conditioner will automatically switch from heating
(where available) to cooling and vice versa in order to
maintain the selected temperature (Heat pump model only).

 

Dehumidification only.
The air conditioner extracts moisture from the air without
changing the sensible room temperature.

A

Ventilation (fan only)

Setting desired temperature

UP
(button D)

DOWN
(button E)

Pressing the UP (D  ) and DOWN (E  ) buttons will increase or
decrease the temperature from the previously set value.
The unit will confirm signal receipt with a beep, and the value of the
set temperature on the display will change accordingly.
The temperature can be set between 17°C and 32°C at 1 degree
intervals.
In cooling mode, if the temperature selected is higher than the
room temperature the unit will not start; the same applies for the
heating mode, if the selected temperature is lower than the room
temperature.

Selecting direction of air flow louvre
(button F)

The air flow direction can be adjusted to optimize air distribution in
the room.
Press button   repeatedly to choose one of the following positions:

Use of the remote controller

Symbol on display

Air direction will be set automatically.
Louvre will be set to the preset position according to the
operation mode.

6 positions can be chosen.
The louvre can be set to one of 6 different air
flow directions.

The louvre will continuously swing up and down.
"TwinSwing" always assures optimal even air distribution
in the room.

In the COOL DRY and FAN mode, the louvre will swing in the cooling
range. In the HEAT mode, the louvre will swing in the heating range.

Note:
Always use the remote control to adjust the louvre position,
otherwise abnormal operation may occur. If you manually adjust the
louve out of its range, please turn the unit off and then on again.

Left and right control
If you want to adjust the direction of the discharge air to the left or
right, adjust the vertical quide vane with the handle after opening
the louvre.

Note:
• Please do not set the louvre to position 

 for a long time,

because this position minimises air circulation resulting in uneven
room temperature.

• Do not adjust the louvre by hand during SWING operation

because it may damage the air swing mechanism.

• If you want maximum cooling or heating capacity, please set

louvre to position 

.

A

Selecting the fan speed
(button G)

The fan speed can be selected by pressing button

A

.

Indicated symbol

A

Low speed
(for night operation)

A

Medium speed

A

High speed
(at start-up, to reach temperature)

A

Automatic
(fan speed will automatically switch to the value required
for optimum comfort).

1

2

3

4

5

6

 Cooling

 Heating

Handle

Содержание Niceday 42PHQ

Страница 1: ...42PHW 42PHQ 42PHQ K OWNER S MANUAL...

Страница 2: ...Infrared remote controller 4 Display of selected functions 5 Unit protection devices 5 Unit display and switch panel 6 Periodical checks 6 Use of the remote controller 7 9 Air cleaning system 10 Optim...

Страница 3: ...d by qualified personnel Do not open the electronic remote controller to avoid possible damage In case of malfunction contact a qualified service engineer This unit contains rotating parts fan Ensure...

Страница 4: ...utdoor unit B Indoor unit System description 1 Automatic swinging louvre 2 Air return 3 Air filters 4 Air outlet 5 Unit operating status indicators 6 Remote control signal receiver 7 Unit nameplate 8...

Страница 5: ...desired functions An acoustical acknowledgement sound beep will indicate that signal has been received Fix the remote control holder to the wall using the two screws The remote control operates with...

Страница 6: ...timer Model Type of protection Effect of protection Operation mode When on Indoor coil Compressor and Heating in During unit operation 42PHQ 42PHQ K high temp protection outdoor fan off heat pump mode...

Страница 7: ...in dusty zones 2 Operations to be carried out by qualified service personnel Refer also to Installation Manual Table II Periodical checks Indoor unit Every month Every 4 months Every year Clean air f...

Страница 8: ...t with a beep and the value of the set temperature on the display will change accordingly The temperature can be set between 17 C and 32 C at 1 degree intervals In cooling mode if the temperature sele...

Страница 9: ...the ON and OFF times the unit will automatically turn on and off at the set times If you press the CLOCK button during Timer operation you will see the current time for 5 seconds ON timer procedure 1...

Страница 10: ...remote control is not operating properly or after replacing the batteries Setting current time 1 Press the TA button with a sharp object and the current time indication symbol flashes At the start 6 0...

Страница 11: ...aning system Standard air filters they eliminate dust and lint Optional electrostatic filter active carbon filter this is particularly effective to eliminate odour and microscopic dust Optional electr...

Страница 12: ...s out of the controller Clean indoor and outdoor units Filter cleaning Clean filters in accordance with the actual operating conditions and times Lift the front panel and pull the air filters downward...

Страница 13: ...operation Any of the following can occur during normal operation A gurgling noise can sometimes be heard during operation or when the unit stops This is the sound of the refrigerant flowing through th...

Страница 14: ...a R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice Order No 14486 74 November 2001 Supersedes Order No new Pr...