6.1
INTRODUCTION
Under normal circumstances, unit problems will be indicated by an active alarm in the alarm list. Suggested trou-
bleshooting actions for each alarm indication are provided in
. Suggested corrective actions for mechan-
ical type problems are listed under subject headings in
.
Table 6–1 Alarm Indications
ALARM
Description
CORRECTIVE ACTION
Reference
Section
A00
No Malfunction
All components functioning normally
--
A01/A02/A03
-
Alternating
Alarm)
Low Pressure Switch Open
or
Unit undercharged
Liquid line filter-drier restricted
TXV strainer plugged with foreign material/ice.
TXV malfunction
Verify operation of evaporator fans.
--
Failed switch
Inspect switch wiring
High Pressure Switch Open
or
Unit overcharged
Verify operation of condenser fan
--
Non-condensables in system
Failed switch
Inspect switch wiring
Electrical Motor PTO Open
Electrical motor overheated
Verify wiring to motor overload
Check electrical motor brush condition, replace
if necessary.
Replace electric motor
A04
Compressor Clutch (CLHR)
Malfunction
Current draw of road clutch coil either high or
low
Replace
A06
Condenser Fan Motor (CFM)
high amp draw
Verify motor rotates freely / no obstructions
--
Replace motor
--