3. Remove adjustment screw and natural gas regulator spring (silver).
4. Install propane gas regulator spring (white) in gas valve.
5. Turn regulator adjustment screw in 6 turns.
NOTE:
DO NOT reinstall regulator seal cap at this time.
B.
Pre-Adjust Two-Stage Gas Valve
The following furnaces DO NOT need have the regulator spring replaced in the gas valve. The valve MUST be pre-adjusted for propane
applications:
CAUTION: UNIT DAMAGE HAZARD
Failure to follow this caution may result in excess underfire and flashback.
The gas valve must be pre-adjusted before operating on propane gas. If left this way, sooting and corrosion will occur leading to early
heat exchanger failure.
→
Fig. 14—Conversion Kit Rating Plate–Single Stage Units
A04119
CONVERSION KIT RATING PLATE - CARRIER CORP.
FUEL USED: PROPANE GAS
ALTITUDE OF INSTALLATION (FT. ABOVE SEA LEVEL) U.S.A. *
APPLIANCE MODELS
0
2001
*
3001
4001
5001
6001
7001
8001
9001
to
2000 to
3000 to
4000 to
5000 to
6000 to
7000 to
8000 to
9000
to
10000
373LAV, 376CAV, 58RAV,
58ZAV,
PG8DAA
Orifice
No.
54
55
55
55
55
1.25mm
1.25mm
1.25mm
56
Mnfld
Press
11.0
11.0
11.0
10.5
10.0
11.0
10.5
10.0
11.0
Orifice
No.
54
55
55
1.25mm
1.25mm
1.25mm
1.25mm
56
56
383KAV, 393AAV, 395CAV,
58PAV, 58WAV, 58YAV,
PG8UAA
Mnfld
Press
10.0
10.5
10.0
11.0
11.0
10.5
10.0
11.0
10.0
* For Canadian Installations from 2000 to 4500 ft use U.S.A. column 2001 to 3000 ft.
327697-206 REV. B
KIT NO. KGANP3001ALL (SUPERSEDES: KGANP2701LPS, KGANP2801F80,
)
KGANP2901ALL
INLET PRESSURE
(min - max): 11.0 - 13.6 in. wc
THIS APPLIANCE HAS BEEN CONVERTED TO USE PROPANE GAS FOR FUEL.
REFER TO KIT INSTRUCTIONS FOR CONVERSION
PROCEDURES.
USE PARTS SUPPLIED BY CARRIER CORPORATION AND INSTALLED BY QUALIFIED PERSONNEL.
SEE
EXISTING RATING PLATE FOR APPLIANCE MODEL NO. AND INPUT RATING.
NOTE: Furnace gas input rate on rating plate is for installations up to 2000 ft above sea level. In U.S.A. the input rating for altitudes above 2000 ft must
be derated by 4% for each 1000 ft above sea level. In Canada the input rating must be derated by 10% for altitudes of 2000 ft to 4500 ft above sea level.
→
Fig. 15—Conversion Kit Rating Plate–Two Stage Units
A04120
CONVERSION KIT RATING PLATE - CARRIER CORP.
THIS APPLIANCE HAS BEEN CONVERTED TO USE PROPANE GAS FOR FUEL.
REFER TO KIT INSTRUCTIONS FOR CONVERSION
PROCEDURES.
USE PARTS SUPPLIED BY CARRIER CORPORATION AND INSTALLED BY QUALIFIED PERSONNEL.
SEE
EXISTING RATING PLATE FOR APPLIANCE MODEL NO. AND INPUT RATING.
NOTE: Furnace gas input rate on rating plate is for installations up to 2000 ft above sea level. In U.S.A. the input rating for altitudes above 2000 ft must
be derated by 4% for each 1000 ft above sea level. In Canada the input rating must be derated by 10% for altitudes of 2000 ft to 4500 ft above sea level.
FUEL USED: PROPANE GAS
INLET PRESSURE
(min - max): 11.0 - 13.6 in. wc
ALTITUDE OF INSTALLATION (FT. ABOVE SEA LEVEL) U.S.A. *
APPLIANCE MODELS
0
2001
*
3001
4001
5001
6001
7001
8001
9001
to
2000 to
3000 to
4000 to
5000 to
6000 to
7000 to
8000 to
9000 to
10000
331AAV,
331JAV,
58DXT,
58TMA
Orifice No.
55
55
1.25mm
1.25mm
1.25mm
56
56
56
57
Mnfld Press
11.0 /
10.0 /
11.0 /
11.0 /
10.0 /
11.0 /
11.0 /
10.0 /
11.0 /
High / Low
4.7
4.2
4.7
4.5
4.2
4.9
4.6
4.2
5.3
Orifice No.
55
1.25mm
1.25mm
1.25mm
56
56
56
57
57
Mnfld Press
10.0 /
11.0 /
10.5 /
10.0 /
11.0 /
11.0 /
10.0 /
11.0 /
11.0 /
330AAV, 330JAV, 333BAV,
333JAV, 58TUA, 58UHV,
58UXT, 58UXV
High / Low
4.3
4.6
4.4
4.2
4.9
4.5
4.2
5.3
4.9
*
For
Canadian
Installations
from
2000
to
4500
ft
use
U.S.A.
column
2001
to
3000
ft.
327697-207 REV. B
KIT NO. KGANP3001ALL (SUPERSEDES: KGANP2701LPS, KGANP2801F80,
)
KGANP2901ALL
58TUA
330AAV
58UHV
333BAV
58TMA
331AAV
58UXV
333JAV
58UXT
330JAV
58DXT
331JAV
—15—