background image

Содержание Infinity GAPAB

Страница 1: ...rical fire hazard only La Infinity Air Purifier certification CSA vise uniquement les risques de choc electrique et Fig 1 GAPAB Unit A06377 SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause personal injury or property damage Consult a qualified installer service agency or your d...

Страница 2: ...t 6 ft recommended and a standard disposable furnace filter should be mounted between the humidifier and the air purifier to trap hard water salt deposits and water droplets Transitions If the return air duct or fan coil openings do not fit the Infinity _ Air Purifier cabinet openings gradual transitions are recommended to reduce air turbulence and maximize efficiency No more than 20 degrees about...

Страница 3: ...finity Air Purifier or door can be rotated 180 to accommodate the cabinet orientation c The location of the Infinity _ Air Purifier should be readi ly accessible Enough room should be provided for peri odic replacement of the air purifier cartridges ELECTRICAL SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service per...

Страница 4: ... provided to attach return duct work See Fig 6 h Seal seams with tape or caulking after the Infinity T_ Air Purifier cabinet has been secured ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death Before installing or servicing system always turn off main power to system There may be more than 1 disconnect switch UNIT DAMAGE HAZARD Failure ...

Страница 5: ...ts bag With the bypass jumper in place the air purifier will be on at all times when connected to electrical line power see Fig 10 d Attach the quick connect terminals to the fused power connector leads in parts bag attached to power cord and connect to incoming field power Attach the ground ring to fan coil chassis ground See Fig 10 r_ I ra Fig 7 Flow Sensor Cable Installed A06414 ELECTRICAL SHOC...

Страница 6: ...N _N BAG A_AONE_L_POWER CORD _ ___ _ TO L2 FIELD POWER SUPPLY _ _ _ _AMP N dNECB 1_ _ _ TOL1F ELDPOWER GROUND _N 2 ATTACH TO FAN COIL GROUND CHASSIS COiL FIELD POWER CONNECTION Fig 10 Fan Coil Chassis Ground A06515 Air Flow Sensor 1 Slide flow sensor tabs into support bracket 2 Rotate flow sensor and clip into bracket Fig 11 Flow Sensor Install A06412 ...

Страница 7: ...ther the TrueSense dirty filter algorithm or time The installer should use their discretion to select the most appropriate option based on the initial system static pressure Step 3 Maximizing Performance a Maximum air purification performance is obtained when the furnace blower is set for continuous operation on the thermostat or Infinity Control Door Switch Magnet X 0 Power Indicator Fig 13 Power...

Страница 8: ...riate protective clothing and gloves when handling parts Step 6 Slide out the Safety Screen and set aside NOTE Best cleaning tools 5 inch handle paint brush with 2 inch width or greater brush point synthetic or natural bristle See Fig 14 or vacuum cleaner with brush attachment Step 7 Gently stroke the ionization pins on the top plane of each bar with enough brush depth to hit front and back tips o...

Страница 9: ... 3 Confirm that the fan coil blower is operating Step 4 Confirm that 208 230 VAC power is provided Attach power supply connector to the air purifier when the fan coil blower is operating NOTE Even though power is supplied to the Infinity _ Air Purifier it will not turn on unless the airflow sensor senses airflow or the airflow sensor s bypass plug is inserted Step 5 Confirm that the airflow sensor...

Страница 10: ...0 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPCCCAR 1620 GAPCCCAR2020 GAPCCCAR2420 Initial Pressure Drop in w c 22 25 22 at maximum airflow Dimensions GAPABXCC1620 GAPABXCC2020 GAPABXCC2420 A 18 t 2 22 25 1 2 B 15 t 8 18 5 8 22 1 8 C 13 t 8 13 t 8 13 t 8 D 17 5 8 21 1 8 24 5 8 E 19 3 4 19 3 4 19 3 4 F 22 I 4 22 I 4 22 I 4 G 11 1 4 11 1...

Страница 11: ...ES AND OR CONDITIONS INCLUDING IMPLIED WARRANTIES OR CON DITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY OR CONDITION IS GIVEN AND APPLIES SOME STATES OR PROVINCES DO NOT ALLOW LIM ITATIONS ON HOW LONG AN IMPLIED WARRANTY OR CONDITION LASTS SO THE ABOVE MAY NOT APPLY TO YOU THE EXPRESSED WARRANTIES MADE IN ...

Страница 12: ... W Mollis St Indianapolis IN 46231 Printed in USA Manufacturer l esel_ es tile right to change at any time specifications and designs without notice and wlt hour obligations 12 Edition Date 02 07 Catalo_ No GAPAB 2SI Replaces GAPAB 1St ...

Отзывы: