6
CARRIER ACCESSORIES
ACCESSORIES
ELECTRONIC AIR
CLEANER (EAC)
Model EACB
AIR PURIFIER
Models GAPAAXCC1625, GAPAAXCC2025
MECHANICAL AIR
CLEANER
Models EZXCAB, FILCAB
HUMIDIFIER
Model HUM
HEAT RECOVERY
VENTILATOR
Model HRV
ENERGY
RECOVERY
VENTILATOR
Model ERV
UV LIGHTS
Model UVL
THERMOSTAT ---
NON---
PROGRAMMABLE
For use with 1---speed Air Conditioner --- deg. F/C, Auto Changeover --- TP---NAC, TC---NAC
For use with 1---speed Heat Pump --- deg. F/C, Auto Changeover --- TP---NHP, TC---NHP*
For use with 2---speed Air Conditioner --- deg. F/C, Auto Changeover --- TP---NRH*
For use with multi---use / stage configurations --- deg. F/C, Auto Changeover/Temperature and Humidity
Control --- TP---PRH
{
THERMOSTAT ---
PROGRAMMABLE
For use with 1---speed Air Conditioner --- deg. F/C, Auto Changeover, 7---Day Programmable --- TP---PAC
For use with 1---speed Heat Pump --- deg. F/C, Auto Changeover, 7---Day Programmable ---
TP---PHP*
For use with 2---speed Air Conditioner --- deg. F/C, Auto Changeover, 7---Day Programmable --- TP---PRH*
For use with 1---speed Air Conditioner --- deg. F/C, 5---2 Day Programmable --- TP---PAC
For use with multi---stage applications --- deg. F/C, Auto Changeover, 7---Day Programmable --- TC---PHP
}
For multi---use / stage configurations --- deg. F/C, Auto Changeover, 7---Day Programmable/Temperature
and Humidity Control ---TP---PRH
{
ZONING CONTROL
Comfort Series™ Three---Zone Kit --- ZONECC3ZAC01, ZONECC3ZHP01
2---Performance™ Series ComfortZone™ Zoning/Temperature and Humidity Control --- ZONECC2KIT01---B
4---Performance™ Series ComfortZone™ Zoning/Temperature and Humidity Control --- ZONECC4KIT01---B
8---Performance™ Series ComfortZone™ Zoning/Temperature and Humidity Control --- ZONECC8KIT01---B
TYPICAL WIRING SCHEMATIC
115-V FIELD-
SUPPLIED
DISCONNECT
AUXILIARY
J-BOX
24-V
TERMINAL
BLOCK
THREE-WIRE
HEATING-ONLY
FIVE WIRE
NOTE 1
NOTE 2
FIELD-SUPPLIED
DISCONNECT
CONDENSING
UNIT
TWO
WIRE
FURNACE
C
O
N
T
R
O
L
R
G
COM
W
C
R
G
Y
GND
GND
FIELD 24-V WIRING
FIELD 115-, 208/230-, 460-V WIRING
FACTORY 24-V WIRING
FACTORY 115-V WIRING
208/230- OR
460-V
THREE
PHASE
208/230-V
SINGLE
PHASE
BLOWER DOOR SWITCH
WHT
BLK
WHT
BLK
NOTES:
Connect Y-terminal in furnace as shown for proper blower operation.
Some thermostats require a "C" terminal connection as shown.
If any of the original wire, as supplied, must be replaced, use
same type or equivalent wire.
W
Y/Y2
GND
THERMOSTAT
TERMINALS
1.
2.
3.
*Model HP and 2S thermostat must be field converted to air conditioner operation.
{
Thermidistat
t
Contro
l
control can be configured for multiple use and staging. It must be configured for each specific application.
}
Dual Fuel thermostat is used with furnace and heat pump application.
A99440
58PH