background image

2

HRV

LHA

1

150

Model number nomenclature

Equipment Type:
Heat Recovery Ventilator

Electrical Supply:
1--- 115 Volts

Maximum Capacity:

100 CFM

150 CFM

250 CFM

Descriptor (A Series):

LHA --- Large Horizontal

SVA --- Small Vertical

SHA --- Small Horizontal

CC

Brand:
Carrier

 

Climate Map for Energy and Heat Recovery Ventilators

ERV Recommended w/HRV or ERV Wall Control

ERV Recommended

HRV Recommended

Honolulu

Sacramento

Salt Lake

City

Boise

Salem

Vancouver

Helena

Edmonton

Calgary

Regina

Winnipeg

Bismark

Topeka

Denver

Oklahoma City

Austin

Baton Rouge

Orlando

Atlanta

Columbia

Raleigh

Washington D.C.

Nashville

Indianapolis

Springfield

Chicago

Des Moines

Minneapolis

Green Bay

Milwaukee

Detroit

Madison

Harrisburg

Hartford

Boston

Syracuse

Montreal

Ottawa

Timmins

HR

V

Содержание HRVCCLHA

Страница 1: ...ale air stream with the fresh outdoor air stream A filter installed on the incoming outdoor air stream removes large airborne particles from the intake air stream before they enter the heat exchanger and reduces the maintenance required The units acoustically engineered design makes the Carrier HRV the quietest on the market and ensures that comfort is felt not heard Unlatching two 2 suitcase styl...

Страница 2: ...gy and Heat Recovery Ventilators ERV Recommended w HRV or ERV Wall Control ERV Recommended HRV Recommended Honolulu Sacramento Salt Lake City Boise Salem Vancouver Helena Edmonton Calgary Regina Winnipeg Bismark Topeka Denver Oklahoma City Austin Baton Rouge Orlando Atlanta Columbia Raleigh Washington D C Nashville Indianapolis Springfield Chicago Des Moines Minneapolis Green Bay Milwaukee Detroit...

Страница 3: ...ntrol Used with all HRVs KVBCN0101CLT Carrier OneTouch Control Used with all HRVs as a main wall control KVAAC0101HCO Intake and Exhaust Hood Used as a single intake exhaust for HRVCCSVA1100 HRVCCSHA1100 only KVAAC0101HOD Exterior Intake and Exhaust Hood 2 Required KVATM010120C 20 Minute Push Button Timer Used with all HRVs when 20 minute manual operation is required KVATM010160M 60 Minute Timer U...

Страница 4: ...d and off Automatic Defrost Cycle Features All models offer a non electric defrost cycle feature which prevents frost and ice buildup within the heat recovery core When the outside air temperature falls below 23_F 5_C it is electronically sensed and the dampers close the outside air ports This allows warm indoor air to recirculate within the heat recovery core The frequency of this cycle increases...

Страница 5: ...Dia 149 2 4 PLCS 2 3 16 in 56 2 4 PLCS 1 in 25 4 2 PLCS 16 3 4 in 4 1 2 in A05228 A B C D Model in mm in mm in mm in mm HRVCCLHA1150 17 1 4 438 2 10 1 2 266 7 4 1 2 114 3 11 279 4 HRVCCLHA1250 17 1 4 438 2 10 1 2 266 7 4 1 2 114 3 11 279 4 E F G Model in mm in mm in mm HRVCCLHA1150 7 3 4 196 9 4 3 8 111 1 7 3 4 196 9 HRVCCLHA1250 7 3 4 196 9 5 13 16 147 6 7 3 4 196 9 Fig 1 HRVCCLHA Unit Dimensions...

Страница 6: ...de Core Type Polypropylene Polypropylene Polypropylene Polypropylene Core Type Polypropylene Cross Flow Polypropylene Cross Flow Polypropylene Cross Flow Polypropylene Cross Flow Weight lb kg 65 29 5 73 33 2 42 42 Shipping Weight lb kg 75 34 83 37 6 48 48 Shipping Dimensions in Height Width Depth 23 1 16 36 1 16 17 13 16 22 15 16 35 1 16 22 15 16 25 5 17 5 23 0 30 0 15 0 23 0 HRV ...

Страница 7: ...8 ft ceiling x 0 35 AC h 60 min h 93 3 CFM Method 2 1 Multiply number of people times 15 CFM person 2 Multiply number of bathrooms times 20 CFM each 3 Add 25 CFM for kitchen Example 2 people 2 bathrooms 1 kitchen 2 x 15 2 x 20 25 95 CFM Additional heating and cooling load charts Although the ventilators process the outside air before it enters the home additional heating and cooling loads need to ...

Страница 8: ...gn enthalpy from a psychrometric chart using the design dry bulb and wet bulb temperatures See following psychrometric chart The cooling load can then be found for a range of enthalpies for each ventilator EXAMPLE The cooling design dry bulb temperature for Milwaukee WI is 87_F and the average wet bulb at that temperature is 73_F On the psychrometric chart the enthalpy is about 37 7 BTU lb of dry ...

Страница 9: ...roperties and enthalpy deviation lines are for ice 25 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0 7 5 8 0 30 35 40 85 90 95 100 105 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 45 50 55 60 65 70 75 80 85 90 95 100 105 110 Enthalpy at saturation Btu per pound of dry air Grains of moisture per pound of dry air 1 4 0 c u ft 1 4 5 c u ft p e r p o u n d o f d ry a ir 1 3 5 c u ft 1 3 0...

Страница 10: ...istribution A99298 Copyright 2005 Carrier Corp S 7310 W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No HRV 4PD Replaces New Printed in U S A Edition Date 12 05 HRV HRV ...

Отзывы: