Under normal operation the detector continuously monitors the oil mist level in the engine.
The Control Panel communicates with each connected detector to obtain the measured oil mist level and
the detector status. The Control Panel determines if the measured oil mist level is above the alarm levels
or if there is a fault condition and activates the appropriate relays.
This information is also displayed on the Control Panel in graphical form on an LCD. A membrane keypad
allows the user to interact with the system.
3.1
SYSTEM POWER UP
On power up the system will perform a sequence of actions:
3.1.1
Detectors
The green power LED on each detector will be switched on indicating power is being supplied to the
detector.
3.1.2
Control Panel
Control Panel membrane will be switched on for a short period allowing a visual check
of their operation to be made.
Following this sequence, the Control Panel Power LED shall be on
The LCD shall show a bar graph for each engine indicating the average oil mist level and indicate that
the system is Normal.
Figure 74
Main Screen
Short lines to the right of each bar graph show the average alarm level for that engine.
3.1.3
Engine Overview
During normal operation the Control Panel will display the Main Screen, Figure 74, showing a bar graph
for each engine.
The name of the engine is shown below the bar graph.
The level displayed on the bar graph indicates the average oil mist level being measured on that engine
at that moment in time. The indicated level will change in real time as the oil mist level in the engine
changes.
3.2
ACCESS LEVELS
There are three access levels available, each allowing access to various options within the system.
3.2.1
User Level
At power up the system defaults to User level access, allowing access to view system information. No
changes can be made to the system configuration at User level.
Содержание Graviner Mk6
Страница 16: ...Nov 21 Page 16 of 132 59812 K001 Rev 10 Height 309mm Width 559mm Depth 118 5mm Weight 8 7kg ...
Страница 26: ...Nov 21 Page 26 of 132 59812 K001 Rev 10 Figure 9 Junction Box Installation ...
Страница 29: ...Nov 21 Page 29 of 132 59812 K001 Rev 10 Figure 12 Detector Head Installation ...
Страница 30: ...Nov 21 Page 30 of 132 59812 K001 Rev 10 Figure 13 Detector Head Installation Short Sample Pipe ...
Страница 46: ...Nov 21 Page 46 of 132 59812 K001 Rev 10 Figure 36 System Drawing ...
Страница 47: ...Nov 21 Page 47 of 132 59812 K001 Rev 10 Figure 37 Wiring Diagram ...
Страница 112: ...Nov 21 Page 112 of 132 59812 K001 Rev 10 6 6 1 CONTROL PANEL Figure 158 Control Panel Door ...
Страница 123: ...Nov 21 Page 123 of 132 59812 K001 Rev 10 ...
Страница 126: ...Nov 21 Page 126 of 132 59812 K001 Rev 10 ...
Страница 129: ...Nov 21 Page 129 of 132 59812 K001 Rev 10 ...