background image

12

 

 

 

 

39004DP452 
01/10 

WARRANTY CONDITIONS:  

1. 

To obtain the longer warranty periods as shown in the table under original owner, for the original purchaser, the product must be properly 
registered at 

www.cac-bdp.com

  within ninety (90) days of original installation.  In jurisdictions where warranty terms conditioned on 

registration are prohibited by law, registration is not required and the longer warranty period shown will be apply. 

2. 

Where a product is installed in a newly constructed home, the date of installation is the date the homeowner purchased the home from the 
builder. 

3. 

If the date of original installation cannot be verified, then the warranty period begins ninety (90) days from the date of product manufacture (as 
indicated by the model and serial number).  Proof of purchase may be required at time of service. 

4. 

The remainder of the first five years of warranty is freely transferable without registration.  To obtain a transfer of the longer warranty periods 
as shown in the table under subsequent owner, a subsequent owner must register the transfer at 

www.cac-bdp.com

  within 90 days of the 

change in ownership and payment of a transfer fee.    Not applicable in all jurisdictions.  See website for details. 

5. 

Product must be installed properly and by a licensed HVAC technician. 

6. 

The warranty applies only to products remaining in their original installation location. 

7. 

Installation, use, care, and maintenance must be normal and in accordance with instructions contained in the Installation Instructions, Owner’s 
Manual and Company’s service information. 

8. 

Defective parts must be returned to the distributor through a registered servicing dealer for credit. 

 
LIMITATIONS OF WARRANTIES:   ALL IMPLIED WARRANTIES AND/OR CONDITIONS (INCLUDING IMPLIED WARRANTIES OR 
CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE OR PURPOSE) ARE LIMITED TO THE DURATION OF THIS 
LIMITED WARRANTY.  SOME STATES OR PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY OR 
CONDITION LASTS, SO THE ABOVE MAY NOT APPLY TO YOU.  THE EXPRESS WARRANTIES MADE IN THIS WARRANTY ARE 
EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON, 
WHATSOEVER.   
 
THIS WARRANTY DOES NOT COVER: 

1. 

Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts, or 
replacement parts, or new units. 

2. 

Any product purchased over the Internet. 

3. 

Normal maintenance as outlined in the installation and servicing instructions or Owner’s Manual, including filter cleaning and/or replacement 
and lubrication. 

4. 

Failure, damage or repairs from faulty installation, misapplication, abuse, improper servicing, unauthorized alteration or improper operation. 

5. 

Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to the inadequacy or interruption of electrical 
service. 

6. 

Failure or damage due to floods, winds, fires, lightning, accidents, corrosive environments (rust, etc) or other conditions beyond the control of 
Company. 

7. 

Parts not supplied or designated by Company, or damages resulting from their use. 

8. 

Products installed outside the U.S.A. or its territories and Canada. 

9. 

Electricity or fuel costs, or increases in electricity or fuel costs from any reason whatsoever, including additional or unusual use of 
supplemental electric heat. 

10.  Any cost to replace, refill or dispose of refrigerant, including the cost of refrigerant. 
11. 

ANY SPECIAL, INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY NATURE WHATSOEVER.

   Some 

states or provinces do not allow the exclusion of incidental or consequential damages, so the above limitation may not apply to you. 

 

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.

 

 

Copyright 2010 CAC / BDP

D

7310 W. Morris St.

D

Indianapolis, IN 46231

Printed in China

Edition Date: 09/10

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No: GAPAA---06SI

Replaces: GAPAA--- 5SI

GAP

A

A

Содержание GAPAA

Страница 1: ...ification CSA vise uniquement les risques de choc electrique et A05265 Fig 1 GAPAA Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause death personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information or assist...

Страница 2: ...on should be done at every change of the air purifier cartridge minimum annually HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death This air purifier utilizes high voltage If you notice water running into or around the air purifier water stains on the purifier cartridge or on the Enhancement Module walls or cabinet shut off the air purifier and call your se...

Страница 3: ...entation c The location of the Infinity Air Purifier should be readily accessible Enough room should be provided for periodic replacement of the air purifier cartridges ELECTRIC SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service person should install the Infinity Air Purifier A thorough check of the unit installat...

Страница 4: ...ow Furnace Note When transitioning between two different sized components furnace purfier the minimum transition angle at the larger of the two components must be no less than 45 degrees A08608 Fig 4 Infinity Air Purifier Cabinet Orientation with Transition Furnace Adapters x2 Return Duct Adapters x4 Return Duct Furnace Adapters x2 Return Duct Adapters x4 Return Duct Top Mount Bottom Mount Side Mo...

Страница 5: ... should be used to connect the upstream side of the air purifier cabinet to the return air duct see Fig 7 g Install foam tape between the furnace and the air purifier cabinet h Mounting holes are provided for ductwork and furnace at tachment Note Slip S cleats onto flanges on air return duct side A05277 Fig 7 Use of Return Duct Adapters UNIT DAMAGE HAZARD Failure to follow this caution may result ...

Страница 6: ... the side of the power supply e Attach the quick connect terminals to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring to furnace chassis ground NOTE The Infinity Air Purifier is to be powered by 115v 60 Hz NOTE The Infinity Air Purifier should only be powered when airflow is present The furnace control EAC spade connections provide power only when the furnace blower is operati...

Страница 7: ...urn the Infinity Air Purifier switch to the off position Remove the Infinity Air Purifier door Slide out the old air purifier cartridge and discard Install the new air purifier cartridge Make sure the power cord is flexed out of the way to avoid damage to the air purifier cartridge pleats during insertion NOTE Verify that the air purifier cartridge is installed correctly Make sure that the arrows ...

Страница 8: ...AREFUL DURING CLEANING Tip of point with residue Tip of point after cleaning A06671 Fig 11 Removal of Deposits from Ionization Pins TROUBLESHOOTING SAFETY HAZARD Failure to follow this caution may result in personal injury or equipment damage The following instructions are for use by qualified personnel only CAUTION ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal in...

Страница 9: ...o cabinet cartridge to cabinet on the leaving air side are securely in place and making clean contact S Arcing to ground such as unit cabinet is occurring S Make sure the safety screen is clear and remove debris S Arcing to ground is occurring due to debris lodged in the safety screen or across ionization grid S Make sure the ionization grid is secured in place with all four clips and centered in ...

Страница 10: ...FM 1600 2000 Efficiency MERV 15 MERV 15 Replacement Cartridge GAPCCCAR1625 GAPCCCAR2025 Pressure Drop Maximum Airflow 25 InH20 25 InH20 Dimensions GAPAAXCC1625 GAPAAXCC2025 A 18 3 8 in 466 7mm 21 7 8 in 555 6mm B 15 1 8 in 384 1mm 18 5 8 in 473 1mm C 11 1 8 in 282 6mm 11 1 8 in 282 6mm D 17 1 2 in 444 5mm 21 in 533 4mm E 22 1 8 in 562mm 22 1 8 in 562mm F 25 1 4 in 642 4mm 25 1 4 in 642 4mm 7 16 11...

Страница 11: ...s and exclusions listed below and on the reverse if any of this document OWNER OCCUPIED RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and is transferable only to the extent and as stated in the Warranty Conditions and below The warranty period in years depending on the part and the claimant is as shown in the chart below Limited Warranty Years Product Original Owner Su...

Страница 12: ...ONS ON HOW LONG AN IMPLIED WARRANTY OR CONDITION LASTS SO THE ABOVE MAY NOT APPLY TO YOU THE EXPRESS WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER THIS WARRANTY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defective...