Carrier EDGE Pro 33CS2PP2S-03 Скачать руководство пользователя страница 5

5

and up to three reset reminders (as enabled by the install-

er). One of the reminders will flash. The display will

show the percentage of time used by that reminder item.

3. Repeatedly press the SET button until the reminder to be

cleared flashes.

4. Press and hold the DONE button for about 3 seconds to

remove the reminder. The percentage associated with the

reminder will be reset to zero.

5. Press the DONE button again.
6. Close the thermostat door.

FAHRENHEIT OR CELSIUS DISPLAY  — The thermostat

is preset to display the temperature in degrees Fahrenheit. The

user can change the display to Celsius if desired. To change the

display, perform the following:

1. Open the thermostat door.
2. Press and hold the buttons underneath the heat and cool

set points simultaneously. The screen will display “01.”

3. Press the UP arrow button until 01 changes to 02. The F

(Fahrenheit) will also be displayed.

4. Press the soft key under the F icon until C (Celsius)  ap-

pears.

5. Press the DONE button.
6. Close the thermostat door.

BACKLIGHTING — The thermostat may feature a low level

amount of backlighting until a button is pressed, which increas-

es the lighting temporarily. The user can adjust the intensity of

the backlighting or turn it off completely. The range is off (OF),

and 1 to 5 levels of brightness. To change the backlighting lev-

el, perform the following:

1. Open the thermostat door.
2. Press and hold the buttons underneath the heat and cool

set points simultaneously. The screen will display “01.”

3. Press the UP arrow button until 01 changes to 03. The

number 3 (the default backlight setting) will be displayed

next to it.

4. To increase the backlight level, press the rightmost soft

key and then press the UP arrow button. To decrease the

backlight level, press the rightmost lower button and then

press the DOWN arrow button. Change the setting to OF

by pressing the DOWN arrow button to completely re-

move backlighting.

5. Press the DONE button.
6. Close the thermostat door.

PROGRAMMABLE / NON-PROGRAMMABLE SET-

TING — It is possible to convert the thermostat operation

from programmable to non-programmable. This eliminates the

advanced features. When switching to the non-programmable

format, the programming, hold, holiday and Smart Recovery

features are lost. Switching to non-programmable operation

also means that some of the thermostat’s energy saving features

are lost. The time of day and day of the week will still  show on

the display and the user will still be able to increase or decrease

the temperature settings manually.

To switch thermostat operation, perform the following:

1. Open the thermostat door.
2. Press and hold the buttons underneath the heat and cool

set points simultaneously. The screen will display “01”

and up to three reset reminders.

3. Press the UP arrow button until 01 changes to 05. The P

icon (the default setting) will be displayed next to it.

4. Press the rightmost soft key and then press the UP arrow

button until the desired operation is shown. P stands for

programmable and nP stands for non-programmable.

5. Press the DONE button.
6. Close the thermostat door.

NUMBER OF PROGRAMMING PERIODS — The    ther-

mostat is preset with four programmable time periods. This can

be changed to two. To change the number of time periods, per-

form the following procedure:

1. Open the thermostat door.
2. Press and hold the buttons underneath the heat and cool

set points simultaneously. The screen will display “01”

and up to three reset reminders.

3. Press the UP arrow button until 01 changes to 06. The

number 4 (the default setting) will be displayed next to it.

4. Press the rightmost soft key and then press the UP arrow

button until the desired number of time periods is shown.

5. Press the DONE button.
6. Close the thermostat door.

DAYLIGHT SAVINGS TIME — The  thermostat  will  auto-

matically change the clock according to daylight savings time

procedures twice a year. Some areas do not use daylight sav-

ings time. To turn off the daylight savings time feature, perform

the following procedure:

1. Open the thermostat door.
2. Press and hold the buttons underneath the heat and cool

set points simultaneously. The screen will display “01”

and up to three reset reminders.

3. Press the UP arrow button until 01 changes to 08. The

ON icon (the default setting) will be displayed next to it.

4. Press the rightmost soft key and then press the UP arrow

button until the desired number setting (OF) is shown.

5. Press the DONE button.
6. Close the thermostat door.

Service Reminders  — 

The thermostat tells the user

when it is time to change the UV light, change the filter, or per-

form scheduled maintenance. Each reminder will be displayed

on the upper left of the screen. For important safety reasons, do

not change a UV light; ask your dealer to replace the UV light.

To remove the reminder after the service has been performed,

press and hold the DONE button for about 3 seconds.

Outdoor Temperature Display  — 

The thermostat

automatically displays the outdoor temperature when the ther-

mostat door is closed if a valid sensor has been wired to the

thermostat. 

Auto Changeover  — 

The thermostat displays one of

five modes: heat, cool, Em heat (heat pump version only), heat

cool (auto mode) and off. When the mode selection is auto

mode, the system is allowed to switch from heating to cooling

or from cooling to heating to maintain the temperature set

points.

Smart Recovery  — 

The Smart Recovery feature transi-

tions the space from one temperature period (occ, occ2, occ3,

unocc) to the next so that the space temperature matches the

temperature set point at the start of each time period. This

means, for example, that if the unocc period temperature set-

ting is lower than the period that precedes it, then the thermo-

stat will start cooling down the space before the beginning of

the scheduled unocc period. The thermostat does this at an en-

ergy efficient rate. This not only helps make the space as com-

fortable as possible, it also makes thermostat usage more cost

effective.

Power Outage  — 

If the building loses electricity, the

thermostat will not need to be reprogrammed. The settings are

retained in memory.

Downloaded from 

ManualsNet.com

 search engine

Содержание EDGE Pro 33CS2PP2S-03

Страница 1: ...ed settings in memory During power loss its in ternal memory saves settings for unlimited time and the clock continues to run for at least 24 hours An extension of Carrier s proven line of thermostats the Edge Pro thermostat provides separate set points for heating and cooling in addition to hu midification and dehumidification OPERATION Thermostat Display The thermostat display is locat ed in the...

Страница 2: ... temporary hold period perform the following Open the front thermostat door An arrow will be displayed next to the words off heat or cool in the upper right corner on the screen de pending on the mode the system is in If it is the first time the thermostat is being used the heat indicator will be displayed The preprogrammed heating or cooling temperatures are dis played in a box at the bottom of t...

Страница 3: ...ays of the week will not fol low the same schedule perform the following 1 Fill in Table 2 with the desired times and set points for each day Use this table as a guide during programming and for future reference 2 Open the thermostat door 3 Press the SET button until the screen displays daily schedule in the center of the screen The list of the days of the week are displayed on the left 4 There wi...

Страница 4: ...ll be displayed when the operating mode is cool 3 Press the soft key under the humidify or dehumidify icons The screen will display the current setting 4 Press the UP or DOWN button to change the humidity setting It is factory set at 26 for humidify and 60 for dehumidify If there is too much condensation in the space set the value to a lower number If the air is too dry set the value to a higher n...

Страница 5: ...wn P stands for programmable and nP stands for non programmable 5 Press the DONE button 6 Close the thermostat door NUMBER OF PROGRAMMING PERIODS The ther mostat is preset with four programmable time periods This can be changed to two To change the number of time periods per form the following procedure 1 Open the thermostat door 2 Press and hold the buttons underneath the heat and cool set points...

Страница 6: ...IPTION E1 The system is not communicating properly Call your local Carrier representative for service E3 The temperature sensor has failed Call your local Carrier representative for service E4 There is an internal memory failure Call your local Carrier representative for service E5 The humidity sensor is not working Call your local Carrier representative for service Downloaded from ManualsNet com ...

Страница 7: ...Downloaded from ManualsNet com search engine ...

Страница 8: ... change at any time specifications or designs without notice and without incurring obligations Catalog No 04 53330031 01 Printed in U S A Form 33CS 26SO Pg 8 6 13 Replaces 33CS 21SO Carrier Corporation 2013 Downloaded from ManualsNet com search engine ...

Отзывы: